Low power - Slow to heat
Replace Magnetron and then I the inverter unit after I discovered the unit still did not heat properly. Inverter had capacitor that was cracked and I found a diode that was flashing over the printed circuit board.
The microwave door would not stay latched, so it wouldn't come on.
The repair was easy, I just took off a few screws and found the broken latch spring. The real story is how easy it was to find the replacement spring from Partselect! I couldn't believe they had it, and even better yet, I ordered it one afternoon, and it came the next day with normal shipping! Unbelievable! Then I just popped it in and replaced the covers I had removed and it was working again!
The only to repair the vent grill was to purchase a new one. I went ahead and found a the replacement part and waited 5 days when it arrived. Very easy installation. Ijust lined it uap amd popped it in place. With a screwdriver I made sure to extend the clips slightly to ensure they fit snuggly to ensure they held the vent tightly
I removed the front cover, which allowed access to the soap dispenser. You need a 1/4" driver set to unscrew the dispenser. I installed the new dispenser, and the dishwasher worked great. The inital problem of the soap door not opening, and the rinse aid not dispensing, was solved.
1. Unplug the power cord from the wall socket. 2. Remove the 10 screws holding the bottom cabinet cover in place. The bottom cabinet cover will swing down allowing acces to the inside ofe the microwave. 3. Remove the connector from the turntable motor. 4. Use a T15 Torx driver to remove the 2 Torx screws holding the motor in place. 5. Remove the motor. 6. Reverse the process using the new motor.
removed grill cover, removed bulb plate, unscrew bulb, screw new bulb in socket,put bulb cover back on and screw grill cover back on. no issues whatsoever.