GASKET OLD LEEKING OUT COLD AIR FROM FRIDGE FOOD WARM
SO SIMPLE I JUST FOLLOWED THE VIDEO THE PARTS SELECT PROVIDED ON THERE WEB SITE AND WALA DONE IN 5minutes Wow THAT EAZY NO TOOLS NESSECCARY JUST A SCREWDRIVER
Parts Used:
Refrigerator Door Gasket
  • Ricky from BUENA PARK, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Evap fan motor comes on and off will not stay running
pulled back panel to get at evap fan motor cut wires to remove reinstalled hooked up wires
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • john from NEWHALL, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noise from fan
I watch the video on your site and this make iit very easy to do. That repair that tooks me 40 minutes.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Reginald from WEST PALM BCH, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My gasket was worn out and torn.
The repair was much more simple to install than I would have imagined. I watched the video provided on your website. What a simple solution to a nagging problem. My fridge looks great again.
Parts Used:
Refrigerator Door Gasket
  • Sharon from FREDONIA, KY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Coils frozen over. Refrigerator not cooling
I cut wires from bad thermostat and removed it . Stripped wires and crimped connectors on new thermostat and wires from old thermostat. Used heat gun to seal sleeves over connectors. Very helpful video from this site Thanks, you will be my go to parts supplier from now on!!!!!!!!!!!!
Parts Used:
Defrost Thermostat
  • Robert from MONTGOMERY, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wasn't getting cold
removed the back panel of the freezer and unplugged the connector for the Motor. Removed the air diffuser, then removed the fan blade. Removed the 2 screws holding the motor to the bracket. Disconnected the old wire harness and installed the new one. Put the fan blade onto the new motor and installed the motor onto the bracket. Put the air diffuser back on, plugged the motor back in and fastened the back panel. Plugged the refrigerator into the outlet and tested, OK!
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Brad from STOCKTON, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Bar had broken
Simply replaced by hand. No tools necessary
Parts Used:
Door Shelf Retainer Bar
  • John from BRONX, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer worked, no fridge
Removed panel over the motor in the freezer department. Removed screws holding the motor in, unplug wires. Reversed process to install motor.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Adam from BERKSHIRE, NY
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer worked, refrigerator didn't. Ice build up on coils.
Unplugged refrigerator. Emptied freezer and removed ice maker and cover, need to unplug fan. Defrosted coils with hot water. Cut wires to thermostat as close to it ad possible to leave extra wire in case of an error. Stripped wire in new thermostat and put in shrink plastic then the wire crimp connector joining both light blue wires making sure wires were in before crimping them. Repeated with other dark blue wire. After used the heat gun to shrink the protective white tubing. The only thing i found not satisfying was tge tubing. It was too wide and too small. When i shrunk it did not cover the whole connector and was loose. I had to use a glue gun to cover both ends of each wire connector. Hope this helps other users.
Parts Used:
Defrost Thermostat
  • Salvador from SANTA ANA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
1 person found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator wasn't getting cold the freezer was getting to cold
Followed the installation instruction for both parts now both the freezer and refrigerator are getting cold
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • eddie from CHICAGO, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door Shelf Retainer Bar Broke
Super easy just snapped new bar in place. Few seconds and the shelf was usable again. Thanks so much for the quick deliver and ease of finding the product I needed. Will return for parts I may need in the future.
Parts Used:
Door Shelf Retainer Bar
  • Mary from Ephrata, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and freezer both freezing at bottom and warm at top.
Unplugged fridge. Removed freezer shelves and unscrewed and removed plastic shelf brackets. Removed the lower rear panel. Removed the bin for ice. Removed the 2 exposed upper rear panel screws. At this point I was able to flex the panel quite enough to access the fan motor. Carefully plugged the fridge back in and turned it on long enough to verify the existing evap. fan motor was not running. Powered off and unplugged again. Removed the fan and it's support assembly, and replaced with new. Had to cut the wires and splice and crimp with the provided wire nuts since the plugs in this model were different. Powered on fridge to check fan function. Reassemble and go home looking' like a hero! Saved my BFF a couple hundred bucks.
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Stephen from PERRIS, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Pliers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator evaporator coil was icing up
The evaporator coil is behind the freezer. Remove the rack that makes the shelf and remove two 1/4” hex head screws I the back of the freezer to access the coil.
I used a hair dryer to melt the ice off the coil.
The thermostat clips on the refrigeration pipe to the coil. Remove the old thermostat and cut the wires at least a few inches from the thermostat. Clip the new thermostat on the pipe and strip about a 1/4” of the wire ends. The electrical connectors (provided with the new part) must be crimped to connect the wires.
Parts Used:
Defrost Thermostat
  • David from VENICE, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Sunnyvale, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Defroster didn't work
Ordered a new defroster timer and replace old one. It works just fine. A $35 repair vs a $500 new appliance.
Cool.
GWE
Parts Used:
Defrost Timer - 60Hz 120V
  • George from Eatonville, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
1 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the WRT18A0AW8