Ice maker leaking, then would'nt shut off.
Ice maker is held by 2 screws just above the unit, on the wall of the refrigerator. You can't see the screws, so borrow your wife's makeup mirror. Shine a light into the refrigerator, and using the mirror, locate the two screws, holding the unit in place, on the wall of the refrigerator. Using a nut driver, or socket wrench, with a 1/4 in socket, loosen up the two screws, but don't remove them. Bump the unit upwards, and away from the screws. (BEFORE doing anything!! Shut off the water supply, unplug the refrigerator) When you get the unit freed up, just unplug the old unit, and install the new one. You don't even have to worry about the water lines, and you'll see why, when you get the old unit off. Just reverse the procedure, installing the new unit. Very Simple, 10 to 15 minutes tops.
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
Turn off power. Remove ice tray. Back out the two screws with nut driver and just lift ice maker off screws. Do not bend the water fill tube in the back . Now unplug the wire and remove ice maker . To replace, match the color of wires on plug. Adjust wires in place and water fill tube and back on to the screws. Hold in place and snug screws. Turn power back on. In 4 to 5 hours your ice will start . FED-EX UT to MN was 13 days to deliver .
defrost heater not working; defrost timer not rotating so coils ice up
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
Seal was old and cracking allowing condesate to rust the door
I should have read everyone else's experiences before attempting. I did view a youtube video and thought I had it set. However, if I had it to do over, the door would have been removed. The door shelf (inner door) taken off and cleaned before attempting to put the gasket on. I did it while the door was still attached and probably lost a good 45mns along with my fingers cramping, knee's flat spotting, and lower back catching fire. TAKE THE DOOR OFF if at all possible, you wont regret it.
Had to reach right hand to top of ice maker to locate hex head screws by feel, then place nut driver onto hex head by feel and then unloosen screws with lft hand ,a couple of turns, enough to lift ice maker off screws. Replace new icemaker onto screws and tighten screws. The only problem incountered was the location and availability of having to feel with both hands to fit nut driver onto the screws.(could not see with my eyes because front of ice maker blocked view. )
Real simple repair..just backed off the two 1/4" hex bolts holding the ice maker to the wall of the fridge,(a little tricky since you can't see them),unclipped the electrical doo hickey. I re-clipped the electrical do hickey of the new ice maker, hung the ice maker on the bolts and then re-tightened them. However,still no ice,my problem was the water valve on the back of the fridge behind the cardboard. Although it was still giving H2O thru the door it was not allowing water to flow to the ice maker. I reccommend pouring some water into the ice tray of the ice maker. If it makes ice and dumps it in to the holder, your ice maker is OK. If it turns out to be your water valve, that fix is easy as well. I HIGHLY reccommend watching the "fix it" video associated with that part. That repair also took less than 15 minutes. Good Luck! KC Bridgewater,NJ
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
removed all items from frig.. removed shelves, loosened one screw on each slide bracket and moved them down and out of the way of the rear panel....removed 6 screws in rear panel...removed all ice on coils with a heat gun...located defrost stat, replaced...crimped wires...re-installed rear panel and shelves! On left side of frig. in front bottom..located defrost timer..removed trim piece, loosened 2 screws....removed and replaced defrost timer...plugged in the frig. and it started!!!!
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
First I determined the icemaker was the problem when it was no longer calling for water. You can hear that "whistle" for 6-7 seconds when it calls for water. Anyway, replacement was a piece of cake, but did not entirely fix my problem. I also had to flush the lines to the soloniods that allow water to flow through the filter and into the water storage tank because it was cloggged with a little piece of plastic.