dryer not heating
I checked the thermal fuse for continuity and had none.ordered part arrived next day. I took a picture with phone to idenify wires. installed in a short time.dryer works like new
Parts Used:
Dryer Thermal Fuse
  • eugene from cheshire, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
The dryer just stopped working one day
To make sure the dryer didn't die catastrophically, I checked to make sure the timer, the light, and the push to start start switch and the door switch were still working. After they were diagnosed to be working properly, I unplugged the dryer and pulled it back from the wall so I would have enough room to work behind it. The first item you will need is the wiring diagram. If you do not have one, one can be obtained online by using your dryer brand and model number. The next thing you will need is a quality digital multimeter that measures resistance or continuity. The last thing you will need is a 1/4" nutdriver. The first thing you will need to do is remove the exhaust tube from the back of the dryer. The second step is to remove a small black plate located near a green ground screw. The 3rd step is to remove the large black cover on the back of the dryer. Once this is removed, you will need to locate the thermal fuse. The thermal fuse is a small component that has 2 blue wires connected to it. It is located on the housing where the steam from your clothes leads to the exhaust port. The first thing you need to do is disconnect the 2 blue wires. Once the wires are disconnected, set the multimeter to resistance. The unit of resistance is ohms and the greek letter omega is used. The red lead of your multimeter goes one metal tabe of the fuse and the black lead goes on the other one. If the multimeter measures 0. L ohms, then the fuse is bad and needs to be replaced. If the multimeter reads 00.00 ohms then the fuse is good and you have another problem. I hope these instructions were useful.
Parts Used:
Dryer Thermal Fuse
  • Tobias from Glenside, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
clothes not dry
Initially confused by instructions provided in that it stated to loosen a brass coupler. Disconnected power. Removed front bottom panel. Disconnected both leads to ingiter. Removed the 2 screws holding igniter bracket in place. Carefully slid igniter and bracket forward and removed from dryer. Removed screw holding ingiter and replaced with new. Reinstalled in reverse.
Parts Used:
Igniter Kit
  • Michael from Webster, NY
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Socket set
Was this instruction helpful to you?