Refrigerator too Warm
tested the thermostat, cleaned the coils, checked seals all clean. defrost timer did not cycle so replaced it but issue not resolved. even though freezer was working while refrigerator was problematic, proceeded to open freezer panel. discovered that fan was not pushing cold air into refrigerator compartment due to ice build up in connecting tubes. cleaned ice and replaced panels to positive result
Parts Used:
Defrost Timer - 60Hz 120V
  • Raymond from Yorktown Heights, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrigerator warm and freezer defrosting too quickly.
1. Disconnected electrical. 2. Removed upper console in refrigerator by removing 2 nuts. 3. Disconnected wiring from console. 4. Removed 2 screws from defroster timer part and pulled off from connector. 5. Replaced with new defroster timer and put everything back together. Thank you Steve for the U-Tube step by step video.
Parts Used:
Defrost Timer - 60Hz 120V
  • Bertha from Lakewood, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
no ice
instructions were very simple. Took about 10 minutes to replace the unit. Do NOT get excited about immediate ice because it took mine awhile to g et cranked up for full production. Anyone can do this! Saves about $150.00 in labor to have someone(no smarter than you) do it for you.
Parts Used:
Replacement Ice Maker
  • Larry from Plains, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Not making Ice/ unit not calling for water
Unplug refrigerator power cord. Remove ice cube bin. Place wire signal arm in down (off) position. Ice Maker is held in place by two (slotted/hex headed) screws through keyhole slots over the top of Ice maker along the left side of freezer. Use mirror to locate screws then carefully loosen (do not remove) screws with a nut driver or screw driver. Lift Ice maker up and right until it releases from the screw heads. Unplug electrical connection. A flat screw driver may be required to loosen connector. Connect new unit electrical and Install new unit over screw heads and tighten screws. Replace Ice Bin and place wire signal arm in the up (on) position. Reconnect refrigerator power cord. After freezer cools down sufficiently it will start making ice.
Parts Used:
Replacement Ice Maker
  • Bob from Celina, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The refrigerator part was not cooling enough
I watched the video online where it described the troubleshooting tips for this type of symptom. So I knew exactly what the problem was which is the defrost timer. After the part came in I just unscrewed (4 screws) the box which houses the thermostat and the defrost timer from top ceiling of the refrigerator section. Then I just unscrewed and unhooked the old defrost timer and replaced it with the new one. After finishing the installation I turned the fridge on. At first nothing happened. So I turned the dial on the defrost timer with a flathead screw until it clicked and the fridge came alive. I waited for an hour or so. The cooling cycle completed and the fridge stopped as expected. When I opened the door I noticed the interior is much colder than before and right after closing the door the fridge hummed back into life again. So I know my fridge is working again. Thanks to PartSelect for providing the right part for my refrigerator. I will definitely buy from them again if anything goes wrong.
Parts Used:
Defrost Timer - 60Hz 120V
  • Mainul from Portland, OR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer cold bottom warm
with patience
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • kenneth from Glendale, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Auger Not Driving Ice Out The Front
Taking it apart is sort of common sense, however putting it back together can be made a lot easier using todays technology of . Digital photography. Take pictures at each stage of disassembly and reassembly be comes very easy and you may only have to do it once instead of multiple times.
Parts Used:
Ice Auger DRIVE BLADE
  • JeRay from Arizona City, AZ, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Refrig unit was frosting up top and bottom, did not properly defrost and stop cooling especially in lower compartment.
Unplug the refrigerator unit from wall. I removed freezer rack, plastic light cover, the ice rack shelf on the right side, then removed the plastic back cover panel, (4) retaining screws, gently tilting the panel toward me, unplug the wiring harness by depressing the clips on the side of the plug, removed panel from unit, set aside. If the unit was froze up, so I defrosted the cooling coils carefully with a common hair dryer until it was thawed. Be careful not to touch or bend the coils , since they are very fragile and SHARP! I located the old thermostat unit attached to a straight length of coolant line. The new unit looked like the old one, so it was easy to locate. I cut the two wires of the old unit close to the round base to make sure I would have enough wire to reconnect. Since my new unit did not indicate a polarity(Neg or Pos), I just wired each wire I cut to one of the new unit. I used the shrink tubing provided and heated the shrink till it was fully melted. I double ck'd to see if the wires were basically waterproof and a good connect. Also, before I replaced the rear panel, I made sure that both wires I had spliced had a drip loop to it so water would not drip down into the newly spliced union. Also made sure the wires will not interfere with the colling fan on the back of the rear panel. Reverse the procedure in reassembling. Plug in unit, and wait and listen for the unit coming back on..I kept a regular thermometer in the upper and lower compartments. Allow 24 hrs. for the unit to return to normal operation. It may defrost several times till the whole operation is back in sync.
Parts Used:
Defrost Thermostat
  • BILL from GENOA, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
Ice maker quit making ice
I followed the video that came with my email receipt but i had to use the extra electrical adapter, there is no where to put the extra wiring so it is hanging next to the wall. I was glad I didn't have to unplug the fridge. just kept the wire up so no water would come out. It took several hours to start working and it doesn't make as much ice as the old one, but at least it works. It was a very informative video. Thanks
Parts Used:
Replacement Ice Maker
  • Richard from Homeland, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer & fridge warm / condenser coils iced over
Problem not consistent. OK for 2-3 weeks, then freeze coils. Mark and observe the defrost timers manual rotating adjuster. Timer would stop mid cycle. One revolution equals 8 hours of compressor run time followed by 30 minutes of defrost. Replacing timer took 5 minutes.
Parts Used:
Defrost Timer - 60Hz 120V
  • Daniel from North Plains, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The freezer coils would freeze up blocking airflow to the refrigerator side.
I needed to determine if the heating coil was ok. I bypassed the thermostat, rotated the defrost timer manually with a flat screwdriver until it clicked. The coil heated up and turned a glowing red. So the coil was ok. After looking at the wiring diagram located on the back, the only parts in line was the timer and the thermostat. So I ordered both, replaced them, and everything is working fine. I went online about noon on Thursday, placed the order. The shipping indicated 2-3 business days. To my surprise, they were delivered to my home on Friday, mid morning. Great service from Part Select.
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Gerald from Piketon, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The ice crusher flap was broken.
Took out the ice box, dumped the ice. Let warm up a bit. Then took out the housing and installed the new one. Works great. Saved a lot of money! Only took a couple days to receive the part. Great service.
Parts Used:
Dispenser Crusher Housing
  • Mary from Allegany, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Coils in back of frezzer freezing up,and freezer compartment not freezing
1st. replaced the defrost thermostat pn 5303918214 did not fix it next replaced the defrost timmer pn 215846602 that did not fix it,next replaced the defrost heater pn 5303918247 still did not fix it,has the same problem as when I started I don't know what to do next guess will call for a service tech to come out,or get a new refridgerator. Looks like I wasted my money on these parts. Refridgerators are not as easy to fix as yall make them out to be. I have to say all the parts were easy to install and your instructions and videos were great, they just did not fix my refrigerator Thanks Tom
Parts Used:
Defrost Timer - 60Hz 120V
  • Tommy from Belton, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Ice maker not generating much ice
We reviewed the video posted on your site for guidance. It was very helpful to see someone do the repair. The project went just as described in the video. Within 24 hours I had a full bin of ice!
Parts Used:
Replacement Ice Maker
  • Patricia from West Greenwich, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
freezer frosted up and air could not circulate to the food section, causing the temperature to get warm, 55 degrees
I followed the procedure online and found the thermostat was ok, it had continuity when cold, and the heater coil was also ok, it too had continuity, therefore the problem was a bad defrost timer. the refrigerator works great, thanks parts select!
Parts Used:
Defrost Timer - 60Hz 120V
  • PAUL from WEIRTON, WV
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the TRS20WRHW3