The refrigerator was leaking water from the freezer section.
First remove all food from the freezer section, disconnect the power to the refrigerator and then remove all the shelves in the freezer.
Then remove the back panel inside the freezer by taking out the screws holding it in and then simply lifting it out. A Philips screwdriver and 1/4" driver was needed.
After the panel is removed, you can see the defrost heater screwed to the refrigerator coils. It's in two sections wired together. One section is screwed to the bottom of the coil and the top section is screwed half way up the coils.
Unplug the wires and thermostat (coming from the defrost heater) from the wire assembly located above the coils.
Next, remove the screws holding the old defrost heater (there are two screws for each element of the defroster)and lift the heater out. Pay close attention as to how the old heater is situated in the freezer in order to put the new one in the same way.
Attach the new heater by putting the bottom element on first and replacing the two screws to secure it. Be careful to keep the wires from tangling and attach the top element the same way.
Next, carefully connect the wires and thermostat from the heater back to the wire assembly the same way they were connected from the old defrost heater.
Place the panel back in place in the back of the freezer section, replace the shelves, and connect the power. You're finished!!
P.S. Don't forget to put the food back in the freezer.
de light flasing on freezer door electronic disply
I removed the back wall panel inside the freezer compartment(approx. 6 screws). The coils were very iced up. I manually defrosted the the coils with a hand hair dryer. I then removed the 2 screws from each heater element and the clip-on thermostat from the coil. I pulled the elements, thermostat and wiring harness(item 230 on parts diagram) out of the freezer compartment and installed the new assembly. Electronic self-check of the defroster indicated normal. Further checks indicated the lower heating element was open.
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new. thanks.
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
This replacement of the light shield was fast and easy. I wish they all good go this smooth.
I repaired as follows. 1) Open freezer door. 2)Removed ice maker bin. 3) removed screw with broken tab on it. 4) install new shield slide to side. 5) Reinstall screw. 6) Grab TAB (tasty adult beverage) and enjoy on back deck while talking about how good you are at repairing stuff.... HA!
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.
New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.
This part on refrigerator went out, wouldn't dispense water.
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.
This Valve Has 2 Different Size Water Lines Going In To It And They Are Different Diameters.Each Has Its Own Collar That Locks The Lines Into It. Make Sure That You Put The Right Size Collar Over The Line Before You Insert It Into The Valve, Because Once You Put The Line In You Cant Pull It Back Out Without Messing Up The Valve. Make Sure It Is Right Because You Only Get One Shot At It.
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.
I began by turning off the refridgerator and then removing all of the drawers/bins and icemaker from the freezer.
I removed the three phillips-head screws across the top of the rear access panel. (same height as the light bulb) I then removed the two phillips-head screws from the bottom of the access panel.
I removed the access panel by swinging the left side forward to clear the drawer slides, while keeping the right side back against itsattaching points. (Like a door swinging on its hinges.)
I followed the wire harness from the upper heating element up to its connector and unplugged the defrosting heaters from the plug. I then gently removed the little (just smaller than a tea light candle) thermostat from the top of the coils. (Not far from where the wire connector was.)
I removed two phillips head screws for each heater unit and removed the whole thing as on big assembly.
I installed the new parts from the bottom up, careful not to damage anything. I installed the new thermostat carefully and then reconnected the wire harness. Next I reinstalled the access panel, starting twith the top center screw to hold it in place during the installation of the other 4 screws in the corners.
Lastly, I put the drawers / bins and icemaker back in and turned the refrigerator back on. DONE.
It corrected the problem. THANKS for the Great Customer Service, too!