Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Refridgerator warm, freezer warming
refridgerater side warming, freezer warming Appliance General Electric Refrigerator
Model TFXW20R
Level of Difficulty Really easy
Time to do repair 1- 2 hours
Age of Appliance More than 10 years
Tools Pliers Nutdriver Screw drivers Dilver From Milton, KY Dec 05, 2011 0 out of 1 people found this instruction helpful
First I diagnosed the problem being a defrost timer as the symtoms are the same as the heater elements. I installed the timer and it worked great for about a week until the frost build up on the evaporator became too much again and then the symtoms returned. I then checked the heater elements and found that both were bad PLUS two clips to the elements were corroded. I then ordered the 2 heater elements. There is more than 1 heater element. Make sure you measure the length of each and then use the graph picture with "Parts Select" on the new ones before you order. There is about a 2" in length difference. Also one comes in a kit with thermostat and wires. Wrong for me. I really wanted that unit as I needed the harness for the bad terminals but it was the wrong heaters and it also came with a new thermostat. Luckly I did not order that one but did order a new thermostat to make sure I did not have to go through this ordeal again. When the parts came I had already replaced the terminals and was ready to go when FedX came. Just make sure you check your heaters before just buying the defrost timer as it may keep you from going back to redo your repair. Just doing your home work before ordering may save you much time in your repair. "PARTS SELECT" was one day on both orders and I just ordered standard shipping. They are great to do business with.
Poped out with screwdriver the old swithch and unplugged the two wires. Plugged in the wires to the new swithch and pushed it back in the hole where the old switch was before.
Removed top hinge and electrical connector (freezer door has ice and water dispensers) then had to turn off water supply to unit and disconnect the hose to the door and remove the spring protector from the hose -- this required removal of the compression fittings in the water line so spring would come off of the tube. Then removed bottom hinge from the door and used saw to remove the rivet that had held the cam to the hinge, used a nut and bolt to attach new cam. Put other cam (used two) in the hinge and replaced lower hinge unit on the door. Then reattached both hinges to the refrigerator and lined up the door put the spring protector and compression fittings back on plastic tubing and reconnected the water supply and electric fitting, turned on water to unit and prayed there were no leaks. Prayer was answered, the water dispenser worked properly and the ice maker filled with water so I then replaced the hinge cover on top of the unit and the grill at the bottom and had a pepsi. A few years ago I had replaced the cams on the other door which had no water/electic connections and was a much simpler job.
refigerator door doesn't close completely by itself
Replaced broken riser cam set. Removed door by taking off top hinge pivot. (cap - 1 screw and hinge pivot - 2 screws). Lift door off bottom hinge pivot. Replace upper cam attached to bottom of door. Replace lower cam and hinge pivot assembly. (2 screws). Place door back onto lower hinge pivot and re install top hinge pivot to secure door. Adjust lower hinge pivot to achieve proper door height.
Switch failed on which kept the refrigerator warm due to heat generatered by light bulbs.
While the switch did last for 9 years, the design is poor due to the failure mode. The failure should be to fail off or not able to turn on the lights which would be inconvenient but would not warm the refrigerator contents. Arcing at the contacts eventually caused the switch to "weld" closed. It is not obvious that this is occurring so it took some time to recognize why the temp inside the ref was high while the freezer was OK. Replacing the switch was easy once it was recognized as the problem. All that was required to replace the switch was to remove the screws holding a fiber cover and then pulling off the aluminum cap which covered the switches. Unplug the switch an squeeze the keeper on the switch to release it and pull down. Pop the replacement switch in place and plug the wires harness back in. All in all it took much less time to replace than it has to write this up. T Pope
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.
Moved all items from door storage into refrigerator shelves. Removed top hinge cover held by single screw and top hinge plate held by two bolts. Lifted up door to clear bottom hinge pin and removed door. Covered open front of refrigerator with plastic wrap to keep cold in refrigerator with door removed. Laid door on kitchen counter top and removed bottom hinge assembly held on by two bolts. Replaced upper cam located on bottom of door and screwed the hinge assembly back on to bottom of door (helps to keep the three plates in same sequence and note the position of cam). Drilled out the rivet that holds the lower cam to the bottom hinge pin. Removed old lower cam and and replaced with new cam and secured to lower hinge assembly with pan head screw and nut (instead of rivet). Replaced door back onto lower hinge pin and secured upper hinge pin with original bolts. Placed cover on upper hinge assembly and secured with original screw. Removed plastic wrap from front of refrigerator and moved the items that originally were stored in the door back to provide weight needed for door to close properly. All done and the door works like new, and all in less than 45 minutes. Would have been a more difficult job without the pioneering of people on this site. Thanks to all!
The existing light switch was very hard to remove. I ended up having to grab it with a pair of pliers and pull it out. Once it was out, it was very easy to put in the replacement and it seems to be working fine.
My husband did the repair, and even though our refrigerator is roughly 20+ years old, he was able to adapt it to work in all the right spots and we now have ice cubes! I'm very happy we did not have to spend $2000 on a comparable refrigerator.
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.
After figuring out how to remove the old broken clip, replacement was easy. Had to use a small putty knife to open the release on the bottom underside of the clip(between the clip & the refrig) . By looking at the replacement piece it was easy to figure out.
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck
Turned off power, removed cover from Ice maker, checked resistance across thermostat for zero (read open), all other switches read proper value (when activated). Ordered and received thermostat. Removed Ice Maker from freezer, removed two screws holding ice tray to Control Assembly. Removed Thermostat and replaced with new one. Applied Silicone Sealant to face of Thermostat for adhesion to ice tray when assembled. Remounted Ice Tray to Control Assembly and remounted in freezer. Works Great...