Light bulbs wouldn't come out of socket

  • Customer: Toni from Denton, NC
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 9 of 10 people found this instruction helpful
I ended up breaking one bulb trying to remove a burnt bulb for replacement. We then tried removing the other bulb and it wouldn't come out either. I googled the problem and found PartSelect and an explaination of the problem. Heat from either the stove or the bulbs had fused the bulbs into the sockets. Comments on the problem explained that you just remove the bottome pannel (we had seven screws), unplug the old sockets, insert the new and new bulbs and reattach the panel. It was quick and no problems to correct. We did discover the microwave was on its own breaker, make sure to disconnect or cutoff power to the microwave before you start.

Light socket replacement

  • Customer: lester from orlando, FL
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 8 people found this instruction helpful
I unscrewed the entire undersurface of the microwave (I didn't do this before!) and replaced the light socket. Easy job and I'm glad the part was still available.

When opening door, the microwave would turn on

  • Customer: William from Fridley, MN
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 8 of 9 people found this instruction helpful
I've been fixing and taking things apart since I was a kid. I hoped that it was a bad switch in the door. Got out my test meter and check the 3 different switches. All 3 tested good, but one was a bit hit and miss. It would work if the microwave was on its side and wouldn't when it was set flat. I found the switch online and installed it. Took care of the problem.It was a whole lot cheaper than buying a new microwave. Thanks! Bill Brown, Fridley, MN

Oven blows 20 amp fuse

  • Customer: PATRICK from Covington, LA
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 9 of 12 people found this instruction helpful
Primary door switch was shorted and blew the fuse when the oven was plugged in. Replaced primary door interlock switch.

broken lens

  • Customer: greg from bellingham, MA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 7 of 7 people found this instruction helpful
first i remove the screw, then removed the lens assembly (really a frame) bent the feet out of the way, slid the old lens out and the new one in, bent the feet back in place and inserted the assembly into place replaced screw. the killer is a day later it was broken again, think the lens can't handle the heat from the oven below or the lights above. you guys where great fast and exact match part but the ge design is flawed

Microwave would not go on

  • Customer: Jim from Lincolnshire, IL
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 13 of 25 people found this instruction helpful
All electrical worked (fan, lights, control panel) door switch was broke. Pulled the oven out. Took out two big screws from the cabinet above. (be careful not to drop oven)Set the oven on kitchen counter. Took off five screws that held the vent cover. Removed vent cover. Took out one screw that held the control panel. Lifted, turned and slid the panel into the space below so I could get to the upper door switch. Replace door switch and re-assemble.

Replace microwave light and broken base socket

  • Customer: Jerry from Pearland, TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 7 of 8 people found this instruction helpful
Lower base of the microwave, about 6 screws,
replaced broken light bulb socket,then re-installed.
Installed new light bulb.

Microwave sparked

  • Customer: Karen M from Bartlett, IL
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 7 of 9 people found this instruction helpful
Original coupler was melted on shaft. I couldn't pull off with pliers, so I removed bottom panel, pulled out motor and the pieces of coupler just fell out. I put on the new one - replaced screws and hurray......

Bulbs broke off in socket, socket would not come out

  • Customer: William from Kingwood, TX
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Pliers, Screw drivers
  • 7 of 9 people found this instruction helpful
I removed both sockets from the microwave and when your part arrived, I installed them both including the new lights. The work perfectly and it was very easy to put them in. I also appreciate the speed of delivery and your concern for my feed back on the product. I have you number in my contact list and should I need another part, I'll check with your first.
thanks you

under microwave (above stove) light

  • Customer: Bruce from Cleveland, OH
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 6 of 6 people found this instruction helpful
The replacement of the light no problem, the reason the light broke; problem. The original was glued in (for transport i think) and simply trying to unscrew it out (in a very tight slot) it broke; be careful or you’ll be buying a new $20 bulb (with shipping and handling).

Loss of lighting for over-stove illumination.

  • Customer: ROGER from BLUFFTON, SC
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 6 of 7 people found this instruction helpful
Must remove 5 screws in bottom of Microwave, which is hinged to the unit. Then simply remove the old lamp holders, and replace with replacements. Uses only a single screw for each lamp.

dirty, needed to be replaced

  • Customer: Brenda from Iowa City, IA
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 13 of 28 people found this instruction helpful
I was very happy with the ease of finding the product I needed, the time it took to arrive and the fact that I received the right part. The replacement process was easy and only took about a minute.

Light Socket replacement

  • Customer: Jill from Arlington, TN
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 6 of 7 people found this instruction helpful
I was told by 2 different appliance technicians that the crumbled/melted light socket could not be replaced which meant replacing the entire microwave (expensive!). Other posters on your sight described the repair steps and I gave it a try. The hardest part was probably figuring out which switch in the fuse box belonged to it (now marked clearly). It was a simple matter of unscrewing the bottom panel of the microwave to access the socket, pulling the crumbled/melted unit off and shoving the new one on. I can't believe the repairmen didn't want any part of even giving it a try.

Bulb was stuck in the lamp

  • Customer: lawrence from huntersville, NC
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 5 of 5 people found this instruction helpful
First I removed the screws that were underneath the microwave. Once I did that I disconnected the wires to the bulbs and removed the screws that were attached to the holder lamp. replaced the parts and reversed the process. It went really smooth.

Bulb burned ot

  • Customer: John from Fort Smith, AR
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 5 of 5 people found this instruction helpful
Un screwed the cover but when i tried to remove the bulb it was broken at the base. I disconnected the power and used neddle nosed pliers to remove the base