Fridge stopped cooling

  • Customer: ray from palm bay FL
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 3 of 5 people found this instruction helpful
I replaced the defrost relay folling instructions I read on the internet--and it still didn't work--So I replaced the compressor start relay which was easier than the defrost relay--it worked and the fridg is working good.

Light didnt go on

  • Customer: dorotea from staten island NY
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 3 of 5 people found this instruction helpful
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!

Installing old ice maker in new freezer

  • Customer: Harry from Ten Mile TN
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 2 of 2 people found this instruction helpful
I was able to transfer my old ice maker from my old Roper Refrigerator/Freezer into my new Whirlpool Sidekick Freezer. Everything transferred directly except for the water fill tube. I ordered one on line and simply cut it to the right length, removed the cover plate inside the freezer compartment and the little sticker from the outside. Inserted tube and fastened in place with two screws (not provided but was able to use the screws that were in the holes inside the freezer before the ice maker went in. Works great. By not buying the ice maker with the freezer I saved a hundred bucks or so.

Refrigerator had shut down

  • Customer: Ronald from Martinsville IL
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Screw drivers
  • 4 of 8 people found this instruction helpful
Went on line ,ordered part on Friday afternoon ,Fedex was at my house Saturday Morning,,THIS SERVICE IS GREAT ,,THANK YOU VERY MUCH FOR BEING SO FAST

Freezer icing up

  • Customer: phil from sioux falls SD
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 4 of 8 people found this instruction helpful
Freezer was running for extremely long periods I noticed and not doing a great job of cooling the fridge.I assumed it was in need of a defrosting so I took the panel off to take a look.
The whole radiator was covered with ice.I could see the defrost thermostat was half way popped out of its casing at a 45 degree angle.
I just had to cut the 2 wires to the defrost thermostat and wire nut the new one in.Very easy fix as the part just clips on radiator.

Filler tube broken and old tube frozen over

  • Customer: Alan from Chino CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 2 of 3 people found this instruction helpful
this is a snap! 2 screws an a nut to tighten and it works like a charm. the filler tube in my Kenmore refer had broken off in the back. ( really bad location to put this in the beginning) if you push the refer to close to the wall you can break it off easily. remove the water line by loosing the nut and remove the hose from the fill tube ( This assumes you have already turned of the water supply or you are standing in a large puddle)remove the 2 screws that hold the filler tube in place. pull out the old filler tube in and slightly upright motion. replace the new fill tube into the same hole and replace the screws. replace the hose and tighten the nut, turn the water back on and check for leaks your done !!
doesn't that feel great?

Broken filler tube at threaded connection

  • Customer: Matthew from Phoenix AZ
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 2 of 3 people found this instruction helpful
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!

Cracked Icemaker Water Fill Tube

  • Customer: James from Ft. Lauderdale FL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 3 of 6 people found this instruction helpful
The plastic part that connects the fresh cold water to the ice maker in back of the fridge cracked.
Do to the fact that Whirlpool has the part stick out on the back top part of the fridge. So if you push the fridge just an inch too far back the plastic part will crack.
I ordered (The Part S&H)- came to about, $11.00.

1. Turned off the cold water under the sink.
2. In the back of the freezer section. I unscrewed the two screws that held the old broken part to the fridge.
3. I opened the freezer section and cleared out the top shelf till I could see the back of the fridge.
4. I removed the old plastic part by pushing & wiggling it about forward and it then extended out the back of the freezer side and then I pulled it out the back and it came out.
5. I slid the new replacement part in basically the reverse of step 4.
6. I connected the hose in the back. To the new, replacement plastic part, that fills the automatic ice tray with water.

7. Once finished I glued a small 2”x2” piece of wood next to the new part so the fridge will never get too close to the back wall so to never break that part that sticks out again.
Before just a small bump could break the part and water is everywhere and this leak could happen slowly at first and the next day what a mess.
Some fridges have this part recessed into the back of the fridge so this would never happen as my other fridge has.
Also, this might seem like more work then it was. It was very simple. I was scared I'd screw it up, but just did it step by step. If I had someone do it. It would have cost me a bundle.
It took more time to type this, then to do the work.
I had no instructions to follow, but again, was easer then I thought it would be.
I hope that this was helpful,
Jim Vourakis

The water fill tube 90 fitting broke

  • Customer: Scott from Crete IL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers
  • 2 of 3 people found this instruction helpful
Removed brokent tube fitting from the compression nut.
Removed two screws holding the fill tube. Removed and replaced the fill tube. Direct replacement, no cutting tube length. Reconnect water line to the new fill tube.......Done.

Lower Light Socket removed and Wires capped with wire nuts

  • Customer: Wayne from Arlington TX
  • Difficulty: A Bit Difficult
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 2 of 3 people found this instruction helpful
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.

We had an accident while moving the refrigerator from one home to another and we broke both handles.

  • Customer: Steven from Cypress TX
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 3 of 6 people found this instruction helpful
All I did was screw the handles on the front door. I had to re-do the freezer handle because I put that one on upside down. I knew I had done so since I was able to refer back to your handly on-line schematic.

lights wouldn't come on/work in refrigerator

  • Customer: Jane from Albuquerque NM
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers, Screw drivers, Socket set
  • 2 of 3 people found this instruction helpful
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!

Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...

  • Customer: David from Hemet CA
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers
  • 2 of 3 people found this instruction helpful
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!

Freezer was dripping water into refrigerator below

  • Customer: John from Redmond WA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 2 of 3 people found this instruction helpful
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.

Freezer made lots of Ice and Refrigerator didn't cool

  • Customer: Cecelia from Garden City TX
  • Difficulty: Really easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers
  • 4 of 9 people found this instruction helpful
The Defrost Timer is located in Refrigerator section (not the freezer) where your temperture guages are. Move panel and replace the non working Defrost Timer with the new one. It took my husband about 30-40 mins to fix. This was about 2 weeks ago and my Freezer and Refrigerator are working like new. I bought this Kenmore Reftigerator brand new in 1996 and I lost the manuel to it. Thanks to my daughter who found the Defrost Timer on the Internet, I thought I was going to have to buy a new one. This was real easy to fix. The instructions that came with the part was easy to understand and very self explanatory. It also had very good diagrams to follow.