Inlet water port was blowing off back of refrigerator allowing water to leak on floor
Cut off water supply remove water inlet valve @ bottom of refrigerator. Replace valve. Replace water inlet port @ top of refrigerator directly behind icemaker allowing glue to dry. Cut on water supply. Avoid opening freezer for 12 hours allowing temperature to become low enough for icemaker to call for water. (A small leak in inlet valve will allow water to freeze in inlet port. When this happens, when the valve opens the water cannot enter because of frozen obstruction, thus blowing inlet port off back of refrigerator). Replace valve problem solved.
Parts Used:
Add-On Icemaker Assembly
  • Michael from Fernandina Beach, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins