Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Fridge would not cool at all, because the compressor was not running. Fan running, lights working, just no cool.
Remove the cardboard access cover at the bottom back of the fridge. On the left side, locate the run capacitor. Remove it by prying it loose from its socket, after first removing the wire hold down clamp. One wonders why the clamp is there, which makes it difficult to get the run capacitor out. Be careful not to disrupt in any way the copper refrigerant tubes. If you mess them up, you will have wasted your time and effort trying to repair the machine. I was lucky, since a failed run capacitor is the problem only about 12% of the time, based on what I’ve read. Hallelujah! It was the problem with my fridge.
Ordered the Capacitor and the Thermostat Control. Parts were received in a matter of a few days, easy to install, but did not fix the problem. Had to call a repairman to fix the problem (compressor relay - this part not available to order for this model number with Parts Select). Will continue to use Parts Select in the future for other parts, but not happy that the actual part I needed was not available - had to use other methods.
Refrigerator was not cooling and the motor was running constantly
Having tried PartSelect.com before, I was very comfortable with the process. Input my symptoms and the feed back I received was that one of the 2 things (Defrost Timer or Defrost Thermostat)might need replacement. Since the cost was not much and over night shipping would cost more than the product, I decided to order both the parts. Changing parts was a breeze. The instructions posted by others on your web site were very easy to follow. You guys save me a bundle every time I have any thing going worng with any of my appliances.
Removed shelf brackets to allow the removal of the evaporator sheetmetal cover. Unpluged wires to thermostat ,removed defrost timer and plugged in new timer,(front left lower kick panel). Cut and resoldered wires to new thermostat reinstalled thermostat and cover in reverse order. I knew what parts I needed and how to repair the unit,however your customer comments were spot on and would help anyone perform a successful repair (you provide a helpful service for the public)
No freezing or cold in either freezer or refridgerator - compressor did not run.
Traced issue to defrost timer ( burned compressor & element contacts). This unit is mounted next to the temperature adjustment control in the refridgerator area - right in front. Removal of plastic cover provided easy access to the timer. Unit unscrews from the mounting then unplugs. Installation is reverse of removal.
After first ordering the wrong end part, I reordered the correct part and successfully attached the handle end and handle to the refrigerator door. The handle itself was too long, and I had to cut it down to the correct size. I am a realtor and provided the service to my buyer of the condo that was my listing. Thank goodness for your company and the ability to buy parts for an old model!
Refrigerator started frosting up and running all the time.I'd defrost it and it would frost up again in about a week.The timer seems to be work so I just guest it mite be the Defrost Thermostat.I removed the duck in the center and back panel in the freezer compartment defrosted it and switched Thermostats and replaced panel and duck, going to lower compartment of the refrigerator.So far it seems to be working a little more time while tell.
Refer iced up and would not keep the bottom cool. It was 70 Farenheit inside.
I simply removed 4 screws holding the casing and then 2 more holding the timer. It was very easy. I then replaced the timer by unplugging and plugged the new one in. I replaced all the screws and the job was done. Less than 30 minutes. I was very impressed with the shipping time. When I ordered the part, I had it the next day.
Freezer built ice, fridge not cold enough and running constantly.
Removed front low grill, removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the wires. Reversed process to install new timer.
took 4 screws out of the discharge vent on top of the refrigerator section and unpluged the wiring harness and put the section on the counter and unscrewed the timer and put the new one in and reinstalled the assembly and plugged the Jack and put the 4 screws back in, and rotated the timer and put it on defrost removed the back and check the heaters and drain .
frezzer iceing over and not cooling the refrigerator
Just removed the two screws and unpluged it. Then I pluged the new one in and replaced the screws. It runs like a brand new reffrigerator. Thanks for the fast delevery. Will do busness with you in the future.