Enter the code DIYDAD10 at checkout to apply your discount. Discount will be applied at checkout when the code is entered & applies to all parts. Cannot be combined with any other coupon or special offer & cannot be applied to a previously placed order. Not valid toward tax or shipping & handling. Discount has no cash value. Discount expires on June 17 at 11:59pm EST.
You've Got 10% Off Your First Order!Save 10% with code at checkout *click to copy coupon code
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Microwave worked intermittently depending on how door was closed
Remove top grille (2 screws), undo control panel (1 screw). Tilt down control panel, switches are on the left. There are actually three switches that are involved with the door, two horizontally mounted, one vertically mounted. This would be an EASY REPAIR, but it took me a while to figure out which of the three switches was bad, and also took a while to figure out that there is a plastic rod that inserts through the hole in the switch body. Once i figured this out went like a breeze. Lower horizontal switch was the bad one, but since the kit came with two switches i went ahead and replaced the upper horizontal one as well. IT appears that the horizontal switches are probably more likely to fail than the vertical switch based on the position of the switch and force angles. Works great now!
The repair went well...I am so glad that I read this info before buying a new microwave....it saved me lots of money. I did have a repair man come and look at it and he told me to buy a new one but it cost alot of money when it wasn't necessary. I did the repair and I was very proud of myself. Three men watched a woman fix this and it was no problem...they were impressed also....
I looked up the #1 reason for no heat for my microwave on the site , and using my model number found that 92% of the time it was the Black Sleeve Diode. Ordered the $15 part, and installed it within 30 minutes. Most of the time was used for removing the built in microwave and removing the cover. Replaced the diode by finding it on the diagram that I printed from this site (free). Very relieved that we don't need to have our custom cabinetry re-sized to accommodate a new microwave. Thank you!
Close the door on the microwave, punch in the # nothing happened
I removed the unit from the wall. Took the cover off. Set the unit on its side. It revealed the working parts. Removed the old micro switches. Put in the new oness. Presto, it worked. Very easy for me. The parts was delivered almost before my notice they were shipped.
removed various screws on tp, bottom and back to remove cover. Thermostat is behind control panel held in with metal tabs. Just bend the tabs straight and remove, install new thermostat in reverse order.
One of the switches in a component that door activates when shut.
I replaced the whole component with all three switches in it even though only one switch was bad . Taking out one switch out of the holder unit would probably have damaged the unit that was holding the switches. Easy install and it works great again .
Small plastic Wheel kept falling off turntable on microwave.
I tried to fix the wheel but the plastic hub had worn too small. After messing with it for a month, I ordered the support ring with 3 wheels from this site. this site said it would fit many brands of microwaves. I was glad I ordered it. It was very affordable and is better than the original. The replacement part is made with heavier duty material than the original and it works perfect. I picked up the microwave plate and grabbed the old one and threw it in the recycle bin and put the new turntable support under the plate, put the plate back on top and closed the door!! Works perfect! Even a novice can do this repair!!
1. Removed cabinet screws (10-15?). 2. Removed cabinet. 3. Removed top interlock switch which actually was not defective. The press clip connection appeared as if it had been arcing for quite some time and the corrosion created resistance sufficient to prevent the current from getting through the switch. 4. Replaced switch anyway but broke plastic retaining clip despite every effort not to do so. Reset broken clip with super glue. 5. Reassembled cabinet and appliance is in good working condition.
Fan motor and magnetron did not come on, but every thing else did.
Problem would come and go. Found service schematic inside unit. Perform all the suggested tests. One possible solution was the primary interlock switch shown on the schematic and a check found the switch stuck. It would free up some times but would stick again in the open position. Ordered switch which was a simple plug in unit.
diagnosed defective 'door-shut switch' in the switch holder assembly. rather than replace switch, replaced entire locker holder assembly which made for a very simple and easy repair...not to mention very inexpensive.
Over the stove microwave installed in top cabinet row. 1. Unplug device. 2. Two people to remove from wall/cabinet (remove two, large, top mounting screws and rotate entire microwave down and off the wall mount). Should be some wood spacers between top of device and bottom of cabinet. 3. Remove screws from sheet metal cover. 4. Remove one screw holding blowers in place and rotate out of the way, in order to gain access to 2 of 5 screws that hold the magnetron in place. 5. Unplug magnetron and remove the 5 screws. 6. Drop in new magnetron and re-assemble microwave in reverse order (steps 5-3). 7. Two people restore micro to wall/cabinet. Replace wood spacers, re-install two, large mounting screws (finger-tight). Test device. Secure the two large screws.
Not knowing which of the switches to replace I ordered all three in the assembly. Replacing the full assembly was easy, first unplug the microwave. Then remove the top cover to access the screws that hold the control panel in place and let the control panel hang. There are two screws that hold the assembly in place - remove those. I used needle nose pliers to pull the wires off of the switches and immediately put the wires on to the new assembly so there was no confusion on what wire went where. Place the assembly back in position, replace the two screws to hold it in, put control panel in place and secure screws. Replace top cover and plug in.