Rear tub seal failure
I removed the top cover and then the back cover, released the belt tensioner and removed the drive belt. Then slid the tub out of the unit and onto the back dack. Sanded the remnents of the old seal off. Wiped the tub lip with laquer thinner and applied the "fast" drying glue supplied with the kit. Installed the seal and re-assembled the unit...works fine
First I took the front of the dryer off then located the igniter. It only required removing two screws, removing old igniter, replacing with new igniter, and replacing the two screws.. While I was replacing the igniter I took the drum out and throughly cleaned the inside. Lucky me, I found 85 cents on the floor of the dryer. I am 65yrs old, married and mother of two. This was easy to do and sure saved money. I reccommend others try to do repairs for themselves and using PartSelect was less expensive too.
First it was a process of alimination to find out why it was dropping out. After the problem was found it was just a matter of replacing the holding coil on the gas valve. Thank you fred kenney sr
This product comes in a bottle with a brush like Liquid Paper. It goes on incredibly easy. A second coat might be needed. I wanted to prevent rust from setting in so I covered the scratches and dings. The paint is a little brighter since my washer is 10 years old but it still looks great.
First I removed the front panel which allowed access to the burner assembly. Then I removed the gas connector and elbow from the back of the dryer. Then I removed 2 screws that hold burner assembly in place and 2 screws that hold an angle brace for the burner assembly. Had to loosen the screw that clamps around the gas pipe holding it in place clear in the back inside dryer housing. Unplugged all wiring connectors, then I removed the burner assembly and removed the 2 screws holding the burner tube to the valve. Remove the orifice and replaced with the proper size for LP gas. Then removed the blocking pin and replaced with one for LP gas. Then reassembled in reverse order. Actually pretty easy.
Unit would shut down in the middle of cycle and flash E1 trouble code
Had to remove the back of unit to access the area of subject part by removeing 12 to 14 screws also the gas line had to be removed. Two screws held the part in place. Unit now runs normal.Saved alot on repair costs!!!!!
I unplugged the dryer,removed the two small screws on the front of the dryer and pulled the bottom forward. The two wires connected to the door do not have to be removed. With an electrical tester using the Ohm setting I tested the Radiant sensor and the Gas Valve coils. The two terminal coil was DOA. The dryer can be operated with the front open as long as the door wires are connected. Symptons: The igniter would heat up and not release gas. My repair was successfull due to this awesome website and the super fast shipping service. AAAA++++
somthing fell down in the blower motor compartment and busted up the bloewr motor fan,and was making noise and out of balance.i changed the blower motor and runs like a charme
the problem was not the igniter its was the thermal fuse I broke the igniter during inspection of the problem be careful its a very easy thing to break repairs complete thank you parts select for the quick shipping and low prices
Our dryer would not heat and it seemed that no gas was coming from the regulator. The igniter was working fine but the burner never turned on. To check the problem, i followed the instructions to remove all body panels until I had access to the burner assembly. I dismantled both gas valve coils and tested each one for open or closed circuit using my multi-tester. I found that the three terminal gas valve coil was an open circuit and was not functioning so I ordered a new one from PartSelect and within just a couple days, had the drier back up and functioning. I also replaced the igniter due to a malfunctioning igniter that has been changed by the manufacture. I must say that PartSelect has the fastest shipping I have ever seen. One part I ordered was at my door in less than 24 hours and I only paid standard shipping...un real! OUTSTANDING....5 STAR SERVICE
I tried to follow directions followed by others on this site after diagnosing the problem via suggestions provided by users. I have a Whirlpool Duet dryer from 2002. We've had problems since moving about 3 years ago. I removed the front panel (lower) by unscrewing the two bottom screws (1/4" sheet metal screws). Then I took out the lint screen and the metal tube/contraption immediately beneath to get access to the area where thermistor is located. See the drawing/chart to help you locate this. It's really easier than it seems. Make sure you have the chart/drawing for your model - it makes difference! The thermistor came out pretty easily with a nutdriver that has a swivel offset shaft. Ask your hardware store tool dept. about that one. Put everything back in reverse order of course and test either with/without the front panel re-attached. In my case it fixed at least part of the problem. I was able to get clothes almost dry with most settings but I have yet to install the moisture sensor to see if that helps in addition to the internal-bias thermistor. I am the kind of person that does one thing at a time so at least I now know the thermistor was bad. Good luck and hang in there with your own repair. It's a lot cheaper even if it takes you longer to do than a pro.
After replacing all the other fuses and sensors I finally replaced the Radiant Flame Sensor and it is working perfectly.
After replacing the other parts and the heat still not coming on I read somewhere that the Radiant Flame Sensor is a normal closed circuit and when I checked with a meter it was open. I would have saved a lot of time and money if I had read that earlier.