Humidistat was inoperatative and the defrost thermostat.
Removed two screws holding the faceplate that held the humidistat. Removed knob, and two screws holding humidisat.. Removed two wires (push on terminals) . Reversed procedure to install new humididstat. Removed defrost thermostat from suction line, cut wires, installed new defrost thermostat, stripped wires, used wire nuts to connect control. Replaced faceplate..
Removed the front cover and then the humidistat from the bracket. Two push on wire connectors and then reversed. Very straightforward and excellent part matching. Given the prices for new dehumidifiers it was great to breathe life back into this unit which does its job well. Thanks for the easy to use web site and fast fast service!
The float turned up missing during a move to another city.
The repair was just putting the float into the inside of the tank itself and then, inserting the two pins (left and right) into each slot so the float operates up and down freely.
The float has two prongs that fit two snap fasteners on the reservoir tank. I just pressed the float prongs into the snap fasterners and inserted the reservoir tank into the dehumidifier. Turned the switch and pressto! We are in business.
Remove the front cover 2 screws on the bottom. Then removed the clip for the full light, then removed 2 more screws that held the humidistat. Removed the 2 power wires removed part. Reverse the uninstall procedure. Done
First I pulled the top/side cover off. Disconnected the terminals from the old unit, unscrewed the old unit, and put the terminals on the new unit. Then I put the side/top cover back on, screwed the new humidistat unit into the front cover and then popped and screwed the front cover back in place. Customer service was excellent and order was received promptly as promised. Highly recommend Parts Select!
First I removed the two control knobs and the two screws that hold the front cover in place and then the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires. Then I reconnected the new humidistat and put everything back together. Works just fine, now.