35 year old water tube became brittle and cracked; leaking water
Unscrewed clamp holding water tube to refrigerator ice maker. Pulled water tube from ice maker and water valve inlet. Cut the new tubing to the exact same length and inserted one end to the water valve inlet and the other end to the ice maker then screwed clamp holding water tube back to the refrigerator ice maker.
Parts Used:
Water Tube Kit
  • Melvin from OPELIKA, AL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The fan quit
I took the old one out and put the new one in. EASY!
Parts Used:
Evaporator Fan Motor Kit
  • donn from Ranier, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water pump for ice maker would not shut off
First I removed the two screws that hold the element in place. I then pulled the element out about 3 inches and disconnected the two wires...) Then I put the new valve in, put the cover back on the refridgerator and was done. total time 15 minutes. My wife says I'm the man.
Parts Used:
Single Outlet Water Valve Kit
  • Lawrence from Clio, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench (Adjustable)
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The Freezer defrosted and everything on the top and the bottom spoiled
i had used your web site before and i read several problems that your readers had. i went to the back of the unit, removed the bottom cover and right there the i found the run capacitor and i chaged it. since i had only ordered this part to save money i went back and ordered the Start Device which when i took it off it was completely burned. the replacement part came labeled with 2 different compressor #, so i picked the one that i had and unpluged each wire. the part may differ from the one that it's in the unit but it worked when i pluged everything back on. it also helps to take a picture of everything before removing the wires in case you have to leave it and come back later. i hope to use this refrigerator another 10 years. thank you all for your help.
Parts Used:
Capacitor
  • Jorge from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
9 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer will not freeze or cool the ice box
I have replaced the circuit board, the condenser fan motor but the unit still will not feeze correctly. The bottom of the unit freezes but just barely cools the rest of the freezer and ice box. Have you got any other advice that might help. This is a side by side unit. What else could be the problem. It seems that the fan is not working correctly or it is stuck in defrost mode. The coils where the fan is seem to be icing up but it will not let the fan work. THanks for your help, David Wilson
Parts Used:
Condenser Fan Motor Kit
  • David from Choctaw, OK
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set
8 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor seized up
First I removed the back cover then removed 3 nuts holding the motor. Next I removed the two wires. Next I attached new connectors to the wires and installed the new motor and everything worked perfect!

Service and shipping were fantastic! I would definitely use Partselect again!
Parts Used:
Condenser Fan Motor Kit
  • Peter from Herndon, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
6 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker slowed down, then stopped producing
First pull out frig and unplug. Shut off water valve. I just had to remove two screws to disconnect unit from bottom rear corner of frig. Pull element out just a few inches and disconnect the plug that feeds it electric. Disconnect water hose and reattach to new unit. Reconnect electric plug and reinstall in back of frig, securing with two screws. I have an older appliance, so I had to jury rig a bit when reattaching new unit by drilling two new holes for mounting. Also, I had to buy a new water hose because the old part would not accept the standard female end of the hose to connect to. Home Depot has the standard icemaker hoses with two female ends. These two glitches would probably not apply to a newer appliance, but anyway, it's cranking out the ice just fine now! Sure I saved alot of money, even with the extra $10 investment for the hose.
Parts Used:
Single Outlet Water Valve Kit
  • Paul from Sharpsburg, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Socket set, Wrench set
5 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water leaked when the paddel was pushed
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Parts Used:
Water Tube Kit
  • Monica from EDMOND, OK
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
6 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
wasn't making ice. The ice bin actually filled up with water.
Removed old valve first, found part # on it.
Entered part # into search box on computer.
It came up with the right replacement part the first time!!!
Ordered part, it came in sooner than I thought it would.
I attached the supply line, pushed in the plastic outlet hose, connected the power line, and attached it to the refrigerator frame. We had a full container of ice the next morning.It couldn't of had been easier.
Parts Used:
Single Outlet Water Valve Kit
  • Bob from Middlefield, CT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The door light socket was broken and hanging down
The refrigerator light in our Kenmore fridge has been flaky for a number of years. The slightest bump would knock it out of the hole it fits into leaving the bulb dangling. Usually since we were used to it, we could avoid bumping it so it was no real problem, but a recent visitor bumped it and it once again was hanging. I decided this time, to take a serious look at it and fix the problem for real. I had options, duct tape, hot glue gun, goop...or a new part! A quick search on the internet, and I found www.PartSelect.com I entered my model # , quickly found the correct part number. The part came 1 1/2 days after I ordered it. The repair was very simple, I unplugged the fridge, removed the wires from the spade connectors on the old light socket, and attached them to the new socket. I then pushed the socket into the hole, and with new spring clips, it snapped snuggly into place. The socket came with extra wire connectors which I didn't need, the socket fits multiple brands of appliances. It also came with a bulb protector, but that wasn't needed for my fridge either. I was very pleased with the speed and ease of the repair. No more dangling light bulbs!
Parts Used:
Light Socket Kit
  • David from Roanoke, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator not cooling properly
Replaced refrigerator cooling control. No luck. Replaced freezer cooling control. No luck. Coils were icing up. Unplugged frig and allowed coils to defrost. After more poking around, found that condenser fan was not spinning. Touch it and it'd start. That was definitely in need of replacement. Replacement was easy. Refrigerator is now running as it should.
Parts Used:
Condenser Fan Motor Kit
  • Ernie from Windsor, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    1- 2 hours
6 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker Quit Making Ice
Ice make was still working but no water coming in to make ice . Pulled refrigerator back and found water valve at bottom of refrig close to the floor. I disconnected water line and electric plug - went to whirlpool web site - no help at all to confusing - found partselect and compaired picture of old valve with picture of new valve . When I got it in mail it took 30 min to install - working fine now hint - mark top of electric plug so you install correctly
Parts Used:
Single Outlet Water Valve Kit
  • WILLIAM from Altamonte Springs, FL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench (Adjustable)
5 of 6 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My U-line ice maker quit filling.
I used this part on a little, under-counter U-line ice maker that is the best little ice maker in the world. The single solenoid part from U-line cost more than twice as much as the generic GE one I ordered from you. It arrived in only 2 days and I was able to just remove the inlet and outlet line from the old solenoid and unscrew the bracket to remove it. I used the included bracket and one screw affix the new one to the ice maker, then just pushed on the inlet and outlet lines, tightened them on, plugged it back in and In about 20 minutes from start to finish, it was back in business, cranking out ice really quick as it was before. Could not imagine summertime in Texas without my U-line,,,Thank you!!!
Parts Used:
Single Outlet Water Valve Kit
  • Anne from Arlington, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken filler tube at threaded connection
After discovering that the water noise was coming from the rear of the refridgerator upon pulling it foward I discivered the connection line had broken. So i got a phillips screw driver and removed the the two mounting screws and saw it was one piece. I easliy found the part on PartSelect website and once I got I merely swaped them out and it works good as new!
Parts Used:
Ice Maker Water Fill Tube Kit
  • Matthew from Phoenix, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower Light Socket removed and Wires capped with wire nuts
My tenants moved out of my rental property and abandoned their refrigerator there. The freezer door would not close properly because someone had previously removed the lower door support bracket and failed to replace the lower bracket shim that positions the lower part of the freezer door properly out from the refrigerator cabinet causing the door gasket seal to bind before the freezer door was fully closed. I removed and replaced this lower door bracket with a new shim made up of serveral thicknesses of cardboard to achieve this spacing and freezer door now closes and seals properly. They had never connected a water supply to the refrigerator although this model is equiped with an ice maker and in door ice and cold water dispenser. The access panel on the back of the unit had been previously removed and discarded. I made up a new access panel from cardboard and connected the water line to the solenoid valve. Valve was so old it would barely open when valve energized and water flow was too slow to make proper sized ice cubes and fill a water glass. I purchased a new water solenoid valve and replaced ther original valve and cured that problem. Replacing the access panel cured an improper cooling problem because with panel removed, most of the air flow bypasses the condenser coils. Lastly I replaced the upper tubular light bulb and the lower light socket I purchased here and installed a 40 watt bulb in the new light socket. Presto! I was able to turn non working abandoned refrigerator into a workable unit.
Parts Used:
Light Socket Kit
  • Wayne from Arlington, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!