Models > KGU6695 > Instructions

KGU6695 Maytag Refrigerator - Instructions

All Instructions for the KGU6695
16 - 30 of 213
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Ice stripper broken on ice maker
I unplugged the fridge. Loosened the 2 top screws on the ice maker and removed the lower screw. I disconnected the wiring harness and removed the Ice maker. I removed the plastic timer cover in front. I then loosened the screws on the face of the ice maker and removed the broken ice stripper and replaced it with a new one. Re-tightened the screws on the face, installed the timer cover, plugged in the wiring harness, re-attached the ice maker. Plugged the fridge back in and walla, it was making ice in 30 minutes!
Parts Used:
Ice Stripper
  • Kenneth from New Braunfels, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
17 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken cup water fill on ice maker
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.

Thanks,
Matt
Parts Used:
Water Fill Cup and Bearing
  • Matthew from Aurora, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
13 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lower left shelf support was broken
I removed all contents from the lower shelf. I, then removed both of the pull out drawers. Secondly, I removed the lower glass shelf and the glass support tray. At this point all four plastic shelf supports were accessible. I removed the inner screw from all four supports and replaced with four new shelf supports. Then reassembled in reverse order. Very easy to do!
Parts Used:
Crisper Drawer Shelf Support Screw
  • Michael from Torrance, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
21 of 41 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was no light on in refrig area
Just replaced the switch, but unfortunately that was not the problem; nor was it the bulb....so I am back to square one.
But Parts Select is a great place to order from. Thank you.
Parts Used:
Refrigerator Door Switch
  • Lori from Chuluota, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
12 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer Door Seal Leak
Installing the seal was fairly easy. the seal as arrived from vendor was very deformed. It came with no instructions. I was able to use a hair dryer to heat the seal and soften the rubber. While softened I pressed the seal into the frame. It slowly began to hold and take shape. Some areas where the seal had been folded in the carton took foam filler to hold into position.
Parts Used:
Freezer Door Gasket
  • Nancy from Dallas, TX
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Screw drivers, Socket set
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The relay had burnt up.
I Removed the two wires from the old relay. I Then pulled the old relay off the compressor. Next, I had to get the overload seperated from the old burnt relay, which took some care not to break. The old relay and overload is in a plastic compartment. Then I followed the directions that came with the new relay. The only confusion came with getting the two wires back onto the terminals of the new relay, mainly because the old relay was burnt so badly I didn't have any idea how it was originally wired. I crossed the two wires on the terminals of the relay. The compressor would click off and on, but would not start blowing cold air. I swapped the wires on the terminals and it started working immediately.
Parts Used:
Relay and Overload Kit
  • Jacob from Glennville, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water dispenser fails to shut off
Upon careful inspection, I found that the dispenser also would occasionally fail to shut off when dispensing whole or crushed ice, which led me to think that the problem was in the dispenser actuator rather than in the water solenoid or fountain switch control board. To inspect the actuator mechanism, I shut off power to the refrigerator, removed the escutcheon mounting screws, the escutcheon, the cable from the fountain switch control board, and finally the fountain bracket assembly. There was a small amount of hard water scale on the back of the actuator pad, but no groove in the plastic part of the pad that actuates the switch. I replaced the pad and switch (1 screw) and reassembled the dispenser. The dispenser no longer sticks and shuts off normally.
Parts Used:
Limit Switch - 2 Terminal Ice and Water Dispenser Actuator Pad
  • Lance from Santa Fe, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch rocker broke, disabling freezer internal light, water dispenser, and ice dispenser
Very simple. Matched female plugs with respective male color coded prong; pushed together then inserted unit in slot of freezer sidewall and rotated into position...job done.
Parts Used:
Door Switch
  • Kenneth from Newton Grove, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The threads on the yoke shaft stripped.
I had to cut off the old yoke since the threads had stripped and it would not come off. Once I did that all I had to do was to remove 4 screws on the auger motor and replace it with the new auger motor. Then I put the yoke on the new auger motor shaft and then put the unit back in the freezer. Work time was less than 15 minutes with no problems.
Parts Used:
Ice Dispenser Engagement Yoke
  • Steven from Crossville, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench set
16 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice machine motor broke from housing & fridge door lower hinge worn, so door is staying closed
Just pulled out ice bucket put to the side and then pulled out framed housing that surrounds the ice bucket tray and put on table
went in the rear where the turn motor is and disconnected the wires from the housing next to it and disconnected the motor which had cracked the wal it was mounted to and broke and fell which left a huge hole and the , took the 4 screws out and remounted it onto the new housing rear wall, note that to get the twist key lever that unscrews clock wise you may have to hit wit a hammer bluntly to brak it lose first then it unscrews easy, but this has to be done first before re assembly of the motor as it goes through the new housing wall , once this is donr then put your screw end through the hole and re assemble the wing devise back onto the moter screw drive which it will screw on counter clockwise and tap a few quick times to snug with a ball hamer or a small hammer, T
The hinge door pin is real easy, just unscrew the top of door 3 screwa and lift off the door set aside put new door pin hinge on then set the door back onto the pin hole align up and set it back down in the hinge hole and replace screws on the upper door hinge on top of fridge. all this took about 5 minutes tops, it took me more time to take all the items out of the doorway of my fridge that it did to do the task itself. Hope this could help.
Parts Used:
Ice Bucket Support Enclosure Lower Hinge Pin
  • David from Spring Hill, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken light switch
followed the instructions provided and that's it!
Parts Used:
Door Switch
  • Richard from West Warwick, RI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replacing thermostat did not help
Icecubes came out half-way, and refrooze. I figured out, that the melter does not work (HEATER in the icemaker) Voltage measured 105V no load. Studied the Internet, and folloved an advice: shorted the back wire and the blackwire with white stripes.these go to relay contacts. It seems, that the relay contacts are no good on Infrared receiver boaed. I turn off manually the icemaker, when needed
Parts Used:
Cycling thermostat
  • John from Rocky River, OH
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Leaking water tube connector/union
Received the union I ordered, then discovered that the tubes were different sizes, so I had the wrong part. I had read elsewhere that it was necessary to trim the two ends of the tubes with a box cutter to stop the leaks - I did this, and the leaking stopped. I was then able to go to a local hardware store and get a 5/16 to 1/4 union and replace it. The leaking is stopped, and the water supply in the door is now working like new. No problem with partselect, but I did buy a caliper so that I can check tube diameters if I ever have a similar problem! This is a great site to find instructions - well worth the time to search!
Parts Used:
Water Tube Connector/Union - 5/16 to 5/16
  • Roderick from NEWTOWN, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Piece
Had to disassemble ice maker to install part. . .
Parts Used:
Water Fill Cup and Bearing
  • anthony from georgetown, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
light not working in fridge
It was so easy!

Thanks for the rush to my home on the part.

I just unscrewed the plate that locks in the light switch (screwdriver) and unplugged the old faulty part and plugged in the new switch, screwed the cover back on and I was done!

Easy!

And I am not Mr. Fix-it!
Parts Used:
Refrigerator Door Switch
  • Michael from East Meadow, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
7 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the KGU6695