Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old plastic ring was damaged due to leaking icemaker causing door to open when ice dispensed.
No tool required! Pulled out tray, emptied ice into large bowl for reuse. Pushed in and pulled from inside the coil springed auger until could get old plastic ring off and put new one on. Useing care not to apply too much pressure to ice dispensing end so as not to break housing. Have to turn auger assembly at an angle to compress enough and get old ring off. Needs a little physical strenth & care not to force plastic housing to breaking point. Worked great reused saved ice. Took less than 10 minutes
Parts Used:
Ice Bin Drive Ring
  • Matthew from Menifee, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Bucket Support Enclosure broken
I removed the broken ice bucket support enclosure using the nut driver and screw driver. The new part had to have the ice bucket motor attached. The metal piece that attaches to the motor shaft had to first be removed, which was somewhat difficult (careful! the thread is reversed). The motor and spring assebly had to be re-attached to the new ice bucket support enclosure piece.
This repair was relatively easy.
Parts Used:
Ice Bucket Support Enclosure
  • Mark from Omaha, NE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch in freezer side got broken
Took a putty knife and
Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Parts Used:
Door Switch
  • Doug from PLEASANT VIEW, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The lightbulb burned out
Replace the refrigerator lightbulb while traveling 88 mph then turned on the flux capacitor being carful not to get stuck in a worm hole. This allows you to fix the problem before it starts to go bad.
Parts Used:
BULB-LIGHT
  • Jennie from ASHEVILLE, NC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Identifying the part on the parts diagram took the longest. Finding the screw driver bit that would remove the old screw that held the original shelf support took longer than the actual repair.
Once I identified the bit that would remove the screw, the rest of the repair took 5 minutes. I removed the screw and discarded the remains of the original but now broken shelf support. With the same screw I simply attached the new shelf support that I received from PartSelect.com. End of story.
Parts Used:
Crisper Drawer Shelf Support
  • Lucien from Cambridge, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Parts Used:
Refrigerator Door Switch
  • THOMAS from WILLARD, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
door would not close and seal on it own
removed three nuts from the top of the door diconected the electrical connections for the ice and water in the door. Removed door by lifting it up about 2 inches, set it aside put new hinge pieces in placed put everything back together. writing this took more time. wanted to add, bought at 2 pm on thursday was at my house by 10am the next day
Parts Used:
Door Closer with Cup Lower Hinge Pin
  • chad from st. Louis, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Parts Used:
Refrigerator Door Switch
  • David from Hemet, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cheap thin plastic the ice augar drive motor is mounted to cracks and breaks the plastic
removed one holding screw (left side center}, used pliers to hold motor shaft so I could unscrew auger drive fork (counter clockwise), then unscrew two screws for ice bucket door magnet push lever, unscrew four screws to auger motor and toss damaged ice bucket support enclosure and don't forget to screw in that one holding screw on lower left side .. then remount both components onto new thin plastic ice bucket support enclosure ... reassemble remaining ice bucket right side wall and slide in main ice bucket with auger. Not a big fix, but part & shipping was just short of $80 ..
Parts Used:
Ice Bucket Support Enclosure
  • Robert from Hagaman, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice dipsenser was malfunctioning
Viewed the repair video. Removed covering. Replaced limit switch, control board, and solenoid. Very easy repair!
Parts Used:
Limit Switch - 2 Terminal
  • Greg from Highland Village, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light didnt go on
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Parts Used:
Refrigerator Door Switch
  • dorotea from staten island, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door light switch disintegrated
Very simple fix, remove 3 screws, two connectors to the old switch
Parts Used:
Refrigerator Door Switch
  • Thomas from Roseville, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Right hand bracket broke off in freezer section
At first I thought I had ordered the wrong bracket but all I had to do was push it up and pull down and it snapped right in place. If a 71 year old lady can do this any body can do it. Thank you for the fast service.
Parts Used:
Door Basket Stop - Right Side
  • June from Apple Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Lower hinge broke, causing the door to jump when open
It is the model with the french door. I unplugged it, removed two screws at the bottom of the door, while holding the door from sliding down. Removed the door and put it on its side. Removed one screw that was holding the hinge, removed the hinge and replaced it with the new one. Put the door back on (do not forget to reinstall the shims).
Did the same thing on the other door. After putting the door back on readjusted the height to level the door, using height adjustment screw. Lock the door in place. It now works better then new
Parts Used:
Lower Hinge Pin
  • Vadim from Flanders, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!