Freezer Super Cold, Fridge Hot. Ice on the back of freezer door.
I initially thought the defrost heater or sensor were bad and replaced them. About a week later the problem reappeared. I ordered the control board assembly and after arrival I did the following: Went on-line, located the part on the fridge parts diagrams and figured out how to remove the controller cover (use two flat screwdrivers from behind). After the cover removal unplug the two connectors and lift out the sensor from its mount. Remove the LED Display/Button Board then the microcontroller board. They literally lift out. With the new controller you have to gently break the display board from the controller - the board is scribed along the break-away area. Do this on a flat surface. The actual board installation and hook-up took less than 5 minutes to reassemble. MAKE SURE THE REFRIGERATOR IS UMPLUGGED - I should have said that FIRST.
Parts Used:
Electronic Control Board
  • Darryl from Mission viejo, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
broken rail prevented crisper drawers to stay in place
followed instructions given; simple fix!
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Linda from Newtown, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!