Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
light on to order water filter
Pressed in the end of the filter cover, lowered it down part way. Twisted the old filter 1/4 turn and removed it. Set in the sink to drain. Inserted new filter and twisted it to lock. closed cover. Done. Total time @ 1 Minute.
removed flap door in front of icemaker...removed 3 screws with bolt heads...removed one additional screw with bolt head and ice unit slid out. I removed motor unit (pops out no screws). Replaced and had ice within 3 hours.
Sometimes the condenser fan would start causing the refrigerator to overheat.
Unplug the appliance. Removed the screws holding the back panel. Removed the fan blade. removed 3 screws holding the condenser fan. Remove the 3 metal brackets attached to the fan. (First note which studs the brackets are attached to. Attach the 3 metal brackets to the new fan. (New screws were supplied) Cut and strip the wire about two inches from the fan. Cut and strip the new wire. I cut the new wire in half (about 6 inches.) Connect the two wires, twist and used 2 wire nuts. Tie wrap the wire to the wire harness. Mount the new fan (three screws) Screw the back panel back on. Mount the new
Removing the existing filter by rotating as directed and then dislodging from 'docking' station proved difficult. Turns out, the old filter is under a bit of vacuum pressure and getting the unit to separate or release was a challenge.
I removed the drop-down outer housing by gently prying the sides of the two pivot pins at the rear. This gave me move 'room' to grip and slightly rotate then pull the old filter forward and away from the tight suction connection. I was concerned that I would be too forceful for the plastic assemblies and would break something; deliberate motions and a steady thought process on the problem helped disengage the darned old filter!
Removed door and crisper pans. Removed nuts on left end cap - think there were 3. Removed nuts on right end cap and one or two on back air regulator attached to right end cap. Replaced left end cap with new one using reserved nuts. Carefully removed back air regulator from right end cap. Attached back air regulator to new right end cap. Replaced right end cap and back air regulator and attached with nuts. Carefully inserted pantry door into pin on one side and slightly bent both right and left pins to insert door fully into end caps. Replaced crisper pans. That's it.
I unscrewed the old one and replaced it with the new one. The real benefit was I got the exact part I needed w/o a 30 minute drive and sales people that ignored me. I had gone to the local store the day before and come home with the wrong part because i could not get assistance and the part # I had did not match what was labled on the package. I used the same part # on the website and got exactly what was needed, less that 48 hrs after I ordered it. thanks for the prompt service. we will be a repeat customer
The Bearing Cup Assembly was broken and ice would jamb against it during the ice making cycle.
I removed the ice maker from the refrigerator, by removing one screw on the underside bracket and loosening the two screws at the top side, then lifting the ice maker off the loosened screws. I then unplugged the electrical harness that supplies power from the refrigerator to the ice maker. I then disassembled the ice maker by removing the front cover which is snapped in place, then removing two recessed screws at the front. I removed the broken part, I then reassembled the ice maker with the new part. I replaced the two recessed screws at the front and snapped on the cover. Then I reinstalled the ice maker in the refrigator by plugging in the harness, slipping the ice maker over the loosened screws in the refrigerator and replacing the screw that was removed from the underside bracket. Tightening all the screws completed the project.
I used a flat-head screwdriver to pop out the old light rocker switch. Then, I unplugged the wires, plugged them into the new light rocker switch, and then popped the new switch into the hole. That's it! Lights began working again.
loud hum from compressor, cycling overload switch, no cooling.
I could hear a loud hum from the compressor motor cycling on/off every 5-10 seconds. Pulled the capacitor and relay switch from the compressor. Checked compressor terminals with ohmmeter, no shorts to ground so it was ok. A gravely substance rained out of the overload relay switch when I removed it, so I assumed it was bad. Didn't need to check the capacitor as it was only another $20 or so to replace. Also didn't notice any oily residue that would signify a coolant leak, so assumed the system was still pressurized. New relay switch and capacitor plugged right in, no tools needed. Re-secured the assembly with it's original keeper clip wire and I was done. Plugged it in and made sure it was cooling properly before replacing the various back cover panels. Like a new reefer! Couldn't have been easier. Just be careful with the capacitor when you remove it. It could hold a lethal electric charge.
Removed shelf drawer. Then removed plastic coverings from back panel of freezer. Squeezed tabs of ice maker connector to push it behind the back panel. With nut driver, removed the four screws holding the panel and removed the panel. Used a hair dryer to remove frost from upper right area that contains the defrost thermostat. Cut out the thermostat and removed the connector on the right from the defrost heater. Removed brown wire from a few of the clips. Attached orange wire from new thermostat to orange wire leading to connector removed from defrost heater and the brown wires to each other using the pliers and supplied crimpable wire nuts. Wrapped the connections with self fusing tape. Reconnected the wiring to the defrost heater and clipped the new defrost thermostat to where the defective one was removed. Used the hair dryer to melt the ice that was covering the drain, then a turkey baster to unclogg the drain. Put everything back together.
Icemaker made a clicking noise then quit making ice
Motor from Part Select was 185W instead of 260W that came out of unit. After a bit of searching online, I found out the 260W had been obsoleted for lack of torque when harvesting ice.
Removal instructions: Unplugged fridge. Then I removed the screw on the bottom right rear of the unit. Then removed the plastic cover that covered the power connector. Pulled out the icemaker by pushing in the tab on the bottom left middle of the icemaker unit and pulling unit toward me. Unplugged the connector on the back right hand side. Removed the cover on the left side covering motor. Took out 3 philips screws and removed old motor with broken axle that spun freely (the source of the clicking noise). Put new motor in aligning harvest arm (the thing with the fingers) and did reverse of removal. Then plugged fridge back in and it started a harvest and the next morning I had a half tub of ice.
The easiest thing to do was pull the ice make off. After taking the 3 screws out of the wall of the freezer, take a screwdriver (flathead) and push on the tab for the electrical plug and wiggle the cord out. Then you can take 3 screws out for the main cover and another 2 screws on the next cover. There's the part, pop it out and replace holding pins and start the process of putting back together the opposite way you took it apart.
Ice maker not initiating harvest cycle (not making ice)
My troubleshooting narrowed down the problem to either the control assembly or the thermostat, so I bought both just in case. The motor assembly fixed the problem and I didn't need to install the thermostat.
The main thing I want to tell others who are doing this repair, however, relates to the thermostat. If you do indeed need to replace the thermostat (#PS380941) there is something you will need that is not included with the part or mentioned anywhere on this site. The instructions with the thermostat indicate you need to apply something called "Aluminastic" to the thermostat when installing it. I don't know about you, but that isn't something I have around the house, so be sure to order a tube of it when you get the thermostat so you don't have to take a trip to the store to get it to finish the repair.