Changing door switch
When removing a non-working door switch, you will see a hooked piece of plastic on the holder locker that looks like a latch. If you try to pull it back in order to either remove the bad switch or install a good one, it will likely break. Instead, you need to pivot the switch (It pivots on a little post which is fitted into a hole at the corner of the switch) out of position so that it is not held back by the 'latch'. Then lift the switch out. If you have to use lots of force anything, you're doing something wrong. Reverse all this when installing the new switch.
-unplug -remove top and front covers -unplug wire connectors from heating assembly -remove heating assembly from metal stand and push out of the way -remove metal stand from dry -pull out heating assembly -install new one in reserve order
Holder bracket broken so Door swithch could not be activated
Part arrived next day! Thank you Parts Select. Holder bracket on older GE microwave was broken so MW would not start because door latch did not activate door switch. Removed front panel unplugged all the wiring (after I had taken a picture) to gain access to the holder bracket. Unplugged the three door switches. Removed two screws that held the holder bracket. Installed three new door switches into the new holder bracket. Positioned the bracket behind the frame and screwed back in the two screws. Snapped in this seven wire attachments, set the control panel back in the microwave and secured it with two screws. I only needed one screwdriver and one needle nose plier to remove the wire attachment from a door switch which made it easier to remove. 40 minutes.
The first holder locker was shipped in a soft envelope and was damaged in shipping. I ordered a second holder locker with instructions to ship in a hard container and mentioned what happened to the first holder locker. The second holder locker was shipped also in a soft envelope and was received damaged.
I notified customer service and have yet to receive a response.
I now have the part on order with a local company. Kenneth Files (831) 688-0740
A 2 yr old could do this snap out. Snap in less then. 30 seconds . What a shame and rip off on appliance repair shops - I called to do this rediculsley 40 second job and the wantvv$125.00!9t more. Omg. I’m a senior/ no wonder God punished the world wit Covid 19! Too many nasty infair. Buii I needed and rip offs.
Unfortunately the filter upgrade for my microwave was not a fit. When I tried it in my microwave my microwave did not work. I thought I was going to have to have a repairman come and check what was wrong. I decided to put the original filter back in and when I did my microwave worked fine. Select Parts Has issued me a refund for the purchase I made that did not work. I am at present still researching for a filter that work for my microwave.
To heat a cup of coffee, user entered "10:00" instead of "1:00". Mess! After cleanup, microwave ran, but would not heat. While running, it made 2 or 3 time the noise volume as before.
I went for the cheap things first. Ohmmeter showed one of the thermostats in the magnetron compartment was open. I ordered and replaced all three thermostats. Still no heat. I took the unit off the wall (aaarrgh!) and checked the oven cavity thermal cutout. It said 7 ohms. I tested by shorting the wires together, but still no heat. So, I ordered the magnetron and diode cable. When replacing the diode cable (be sure to discharge the big cap!) either I broke it, or it was already damaged. It came off in two pieces. The new diode cable was re-enforced with thick heat shrink tubing, to prevent such breaking. You need a very short screwdriver to replace the magnetron. Now, all fixed! ~$150. A new one lists for $2000, installed in the overhead. My wife thinks I am a genius.
mtg plate came and the rest was easy,did wiring in upper cabinet 4 microwave,drilled 1 1/8 hole in btm of cab 4 power cord 2 go thru.All this was done by common sence and a tape measure,no templates were with this unit (YARD SALE)GE1600,3 bolt holes 2 hold micro upafter installing on back plate,plugged it in and it worked! end of story.