Models > JE1860GB002 > Instructions

JE1860GB002 General Electric Microwave - Instructions

All Instructions for the JE1860GB002
31 - 45 of 45
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
microwave won't heat
bought a fuse but that didn't solve the problem. Guess I need a new microwave
Parts Used:
FUSE
  • Stephanie from Kernersville, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Timer operated normally, but the microwave did not heat water or cook food.
Our GE Profile Advantium 120 Series Over-the-Range Microwave stopped working. We called GE Service. The first available appointment was two weeks after our call. The technician charged $99, gave us a form stating that the Magnetron and Diode Cable as defective and quoting an additional price of $362 to furnish and install these parts. He said that it would be another two weeks before he could do the work. Instead I ordered the parts from you and had them within two days. The parts you furnished were identical to the original parts in our unit. They arrived within two days. I installed the parts without removing the microwave from the wall. The most difficult part was inserting the magnetron mounting screws into openings in the rather tight space available. I was able to do this by using plastic pacaging tape to hold the screws onto the end of a short Phillip screw, Prior to iserting each screw I pushed it through the sticky side of a piece of packaging tape. I then folded the sticky surface over the shank of the screw. Once a screw was seated, but before it was fully tightened, I used needle nose pliers to pull off the tape. The unit now functions perfectly.
Parts Used:
Magnetron Diode Cable
  • Peter from Severna Park, MD
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Cover stirrer melted because microwave was left on with nothing in it.
I only had to snap the parts into place
Parts Used:
COVER STIRRER FAN BLADE-STIRRER
  • Norman from Raleigh, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
Was this instruction helpful to you?
Thank you for voting!
Powered Off completely
After reading reviews that there was no power what so ever and a fuse replacement will solve the problem, I tried it. Replacing the fuse is very easy (and I am not handy at all). All you have to do is remove the microwave cover from the top by removing two screws, slide the cover to the left and pulling the cover off. Then remove the grill in front of you, by removing one or two screws. The fuse is in front of you, use pliers and be firm but gentle. Replacing the fuse is easy but it did not solve my problem.
Parts Used:
FUSE
  • Mohammad from Piscataway, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
The tray was not rotating.
Follow the instructions I got from the website and replacing the motor was very easy to do. Thank you.
Parts Used:
MOTOR SYNCHRONOUS
  • J Roberto from Houston, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All power to the microwave went out.
PartSelect had helpful repair instructions on-line which made the repair easier and faster. Unfortunately, there were other problems with the oven that immediately blew the new fuse I had just installed. It was then determined that additional repair would most likely cost almost as much as a new microwave.
Parts Used:
FUSE
  • Michael from East China Township, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Renter broke the tray
Very easy you just have to make sure that the tray is in the groves for the wheels :)This is the best place to shop as I have used them on all kinds of appliances and they have never let me down when it comes to price and delivery time!
Parts Used:
Glass Cooking Tray
  • Tammy from Buckeye, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
microwave just stopped working
First unplugged the microwave, took top grill off, took control panel off, took wires off and used color coded tape to make sure they went back in right places, took fuse out and replaced it and put every thing back and it all worked fine and to top it off my wife did it all. So it was pretty easy.
Parts Used:
FUSE
  • James from Fall Branch, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Timer, light and control pad worked. Turn table and heat did not work. Oven would not start up.
I first read where someone had the same problem. Their solution was a burned-out fuse. I ordered a new fuse...installed it and that did not solve my problem. I revisted PartSelect and read how Marla (from Arlington, TX)solved her problem. I purchased a secondary switch and when it arrived, I made a copy of Marla's instructions and followed them to the letter. I installed the new secondary switch into the secondary space, put everything back together and the oven STILL DID NOT WORK. I had to take the latching panel apart again and test each switch to see if there was another bad one. I found that the third switch was burned out. So I took the new switch out of the second slot and installed it into the third slot. I tested the switches before reinstalling the latching panel. This time everything worked. So I put everything back together, reinstalled the microwave on the wall, tested it again, and everything worked perfectly.
Parts Used:
FUSE
  • Pearlie from Beulaville, NC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
No heat
Replace the fuses
Parts Used:
FUSE
  • Edwin from New York, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Small explosion inside unit blew out the flame sensor
Unit was painted inside recently, but apparently some paint fumes still lingered so that when the unit was turn on, there was a very small explosion that took out the flam sensor thermostat. This thermostat interrupts the white leg of the AC input and cuts off all power.Performing a continuity test on the flame sensor showed it was permanently open (no continuity). Turns out I had a similar part from an old coffee maker and when I installed this part, the microwave turned on just fine. So I order the correct sensor from Parts Select. Part installation involved removing the TT20 Security Star bits (4) and the right/left side phillips screws. Now the top/side unit cover comes off by pulling the cover backwards and up and out. The flame sensor is in the middle of the front section underneath the top cover, and comes out easily with pull-off connectors. There are also bendable pins that hold the sensor down flush to the top of the unit.
Parts Used:
Flame Sensor Thermostat
  • Paul from Palm Coast, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
no heat
unplug the unit then pull down , lot of screws are on top. open the cover . you could see the parts that need to replace on the right hand side (heavy side). disconnect wires then test the parts that need to replace by a tester to make sure that it's really broke .then unscrew part and replace .
Parts Used:
Magnetron
  • Nelia from Streamwood, IL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Quit working
Just like the directions said. Very simple.
Parts Used:
FUSE
  • William from Socorro, NM
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
I broke my microwave glass cooking plate.
I received my replacement and it is perfect! Thank you so much for for your fast shipping and delivery.
Parts Used:
Glass Cooking Tray
  • Marissa from Cypress, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
The glass turntable was cracked in half
I removed the new tray from the box and slid it into the microwave. That's it.
Parts Used:
Glass Cooking Tray
  • Kristy from Blue Bell, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the JE1860GB002
31 - 45 of 45