Broken light switch
Watched video. Unplugged refrigerator and popped out switch. In plugged connector and pushed switch in place. Plugged in refrigerator and the light worked
Parts Used:
Door Switch
  • Terry from WARMINSTER, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Seal wouldn't seal on the freezer's right bottom. When you shut the refrigerator door with any force the freezer door would come open a tad.
Removed all 50 screws and replaced the seal. The door still comes open a tad but now it seals all the way. This was my first and last Maytag.
Parts Used:
Freezer Door Gasket
  • Shannon from Chapin, SC
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator light would not stay on
Removed the 2 screws holding the light bulb shield, then the 4 uolding the metal panel. Unplugged the olw door switch and replaced.
reassembled the pieces.
Parts Used:
Refrigerator Door Switch
  • Dave from Manchester Center, VT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Socket set
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water Fill Cup Broke
The Ice maker unit had to be removed and the shaft had to also be removed, which required dis-assembling the motor drive. The thickness of the shaft and the bearing fill cup prevents it from simply pushing it in place. Other than that I have Ice.
Parts Used:
Water Fill Cup and Bearing
  • Sam from Las Vegas, NV
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
5 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Old plastic ring was damaged due to leaking icemaker causing door to open when ice dispensed.
No tool required! Pulled out tray, emptied ice into large bowl for reuse. Pushed in and pulled from inside the coil springed auger until could get old plastic ring off and put new one on. Useing care not to apply too much pressure to ice dispensing end so as not to break housing. Have to turn auger assembly at an angle to compress enough and get old ring off. Needs a little physical strenth & care not to force plastic housing to breaking point. Worked great reused saved ice. Took less than 10 minutes
Parts Used:
Ice Bin Drive Ring
  • Matthew from Menifee, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Water Fill Cup and Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator door seal leaking and the beer was not getting cold.
Removed the inner door panel held on by 30 small nuts crews. Removed the old seal. Stretched new door seal onto inner door panel. Attached inner door panel and seal to inside of refrigerator door. Using a magnetic nut driver was the answer in the tight spots and the small nut screws. Everything works fine and the beer is cold again!
Parts Used:
Fresh Food Door Gasket - Black
  • Michael from Hilton Head Island, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The lightbulb burned out
Replace the refrigerator lightbulb while traveling 88 mph then turned on the flux capacitor being carful not to get stuck in a worm hole. This allows you to fix the problem before it starts to go bad.
Parts Used:
BULB-LIGHT
  • Jennie from ASHEVILLE, NC
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    More than 2 hours
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch in freezer side got broken
Took a putty knife and
Removed the old switch removed the spade terminals from the old switch and replaced them on the new switch and just pushed the new switch back in place
Parts Used:
Door Switch
  • Doug from PLEASANT VIEW, TN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Bucket Support Enclosure broken
I removed the broken ice bucket support enclosure using the nut driver and screw driver. The new part had to have the ice bucket motor attached. The metal piece that attaches to the motor shaft had to first be removed, which was somewhat difficult (careful! the thread is reversed). The motor and spring assebly had to be re-attached to the new ice bucket support enclosure piece.
This repair was relatively easy.
Parts Used:
Ice Bucket Support Enclosure
  • Mark from Omaha, NE
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
Parts Used:
Refrigerator Door Switch
  • David from Hemet, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
cheap thin plastic the ice augar drive motor is mounted to cracks and breaks the plastic
removed one holding screw (left side center}, used pliers to hold motor shaft so I could unscrew auger drive fork (counter clockwise), then unscrew two screws for ice bucket door magnet push lever, unscrew four screws to auger motor and toss damaged ice bucket support enclosure and don't forget to screw in that one holding screw on lower left side .. then remount both components onto new thin plastic ice bucket support enclosure ... reassemble remaining ice bucket right side wall and slide in main ice bucket with auger. Not a big fix, but part & shipping was just short of $80 ..
Parts Used:
Ice Bucket Support Enclosure
  • Robert from Hagaman, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
defective light switch
inserted a knife between the switch and the plastic interior in order to pop the switch out.
then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Parts Used:
Refrigerator Door Switch
  • THOMAS from WILLARD, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
3 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the GS2726CEDB