The freezer coil was frosting up blocking airflow to refrigerator side
I first unplugged the refirgerator. Note the time because the refrigerator should be unplugged at least 30 minutes before plugging back in (see end for why). A trouble light is necessary to see adequately. I removed the shelves and draws and put food in a picnic cooler. I took off the lower panel in the back of the freezer, and defrosted the coils with a hair dryer. I unplugged the wires to the defroster, and then the screw holding the coil to the back of the freezer side. I lifted up on the coil unit to clear the blade that inserts into the drain. I removed the bands on the top of the coil that hold the heating unit in place. I tilted the bottom out when there was clearance, and pulled the defrosting unit down and out. I replaced the new one, and reversed the procedure, and then plugged the wires back into the new defroster unit. The bands on the top should be secured before putting the coil back in place, as well as the foam spacers on top of coil, put the two wires back in the plastic clip that keeps them away from the fan and pipes. Replace lower freezer cover panel and screws. Put shelves and food back in. If at least 30 minutes have passed, plug the refrigerator back in. If you don't wait that long, their will still be pressure in the compressor and it will not start to cool properly right away. It works perfectly now. TIP: check the end of the drain hose periodically by taking off the lower back cover and pull th hose out - not hard to do. Mine plugged from dust and lint build up backing up into the end of the hose so water didn't drain out, and ice built up causing the defroster coil to burn out. I cut a little off the hose so the water level would not rise up into the hose, but the hose would still stay in place in the plastic holder.
Parts Used:
Defrost Heater
  • David from Chetek, WI
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
11 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The plastic that held the drawer in place broke
I called Part Select and ordered a new drawer. They got the item to me within 3 days! I would definitely recommend them to a friend.
Parts Used:
Lower Crisper Drawer Lower Storage Drawer Front
  • Ann from Marriottsville, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
12 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Odor like burning Electrical all through refrig.
Remove back panel inside Freezer compartment remove 2 screws that hold (small) fan motor. Unplug electric motor supply and install new motor in reverse order
Parts Used:
Evaporator Fan Motor
  • Gordon from Marlborough, CT
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
14 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
frezer not staying cold enough to freze newly added product
took the shelves out, unscrewed the rear panel,unpluged the thermistat and uncliped it from the line.Replaced with new thermistat in the reverse order. Before turning the unit back on,allowed the coils to defrost.All of the process was shown in your vidio that I was able to view while ordering the part. Thank you
Parts Used:
Defrost Thermostat
  • Robert H. from Grand Blanc, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
13 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
housing-crusher was broken
removed ice maker box and disassembled crusher unit on front of box and installed new housing.
Parts Used:
Dispenser Crusher Housing
  • Bob from Milton, WV
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
12 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice crusher blades not working
got replacement ice container with ice crusher and dispenser in the door. removed broken one and slid in the new one like a drawer and started crushing ice right away!!
Parts Used:
Ice Container and Auger Assembly
  • Rebecca from Athens, AL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
11 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Rust had corroded Front Plate and Drive Blade
Installation was completed by following the online Parts diagram. Had to completely remove all parts, including the blades in ice crusher, and re-assemble. Glad the online diagram was clear and easy to read.
Parts Used:
DRIVE BLADE Front Plate Screw
  • Calvin from Massillon, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Screw drivers
11 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
There was a hole in the plastic bin where ice fell through to the freezer.
I removed the screws that held the the ice dispencer from the bin. I than removed three screws from the bottom of the bin. I put the new plastic piece on the end of the spiral piece that
pushes the ice. I inserted the spiral piece back into the hole. I than screwed the ice dispencer
to the bin and re-inserted it back in the refrigerator.
It took me about 5 to 10 minutes. It's really easy!
Parts Used:
Ice Container/Bucket
  • Thomas from Niceville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The ice would not come out of the front door. The flap between the door and the ice would not open.
Popped off the front access panel. Removed the heat motor and repalced with the new one. It is fixed and working great. Partselect Delivered the part the day after I ordered it. Thanks!!
Parts Used:
Heat Motor
  • Larry from Cordova, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker was not making ice
I replaced the solenoid first because the ice maker was not getting water. After replacing the solenoid valve, I waited about 1/2 an hour, still no water. So, I ordered a replacement ice maker. I then installed the replacement ice maker, waited a 1/2 an hour, still no water. Then, I waited overnight. Yeah, ice! WORD OF ADVICE. WAIT OVERNIGHT TO SEE IF THE ICE MAKER CREATES ICE. Not sure how long a cycle takes, but it's longer than you would think. Hope your installation is a success!
Parts Used:
Replacement Ice Maker
  • Jeffrey from Indianapolis, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No water for ice maker and for water spout
Pull out the unit from the wall, Unplugged the frig, removed the lower cover panel. Remove 2 screws holding the water valve from the unit, then removed the 2 connectors that turn on the relays. Connected the connectors to the new valve, then replaced inside of unit and replaced the lower back panel cover, plugged it back in, then tested the water flow at the spout, and waitied for the ice maker to kick in. Worked perfectly.
Parts Used:
Dual Inlet Water Valve - 120V 60Hz
  • Frank from Terrell, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
9 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condensor fan motor failed
Removed the old fan--three small nuts and snap off connection. Ordered part and received the next day. Your company is great!!
Parts Used:
Condenser Fan Motor Kit
  • Guy from Califon, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
11 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker failed
Watched YouTube video. Very easy. Used my cell phone camera in ‘selfie’ mode propped up in the upper right hand corner of freezer to see the 2 hidden screws.
Parts Used:
Refrigerator Ice Maker Assembly
  • Mary from SOUTH LYON, MI
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The drum ice maker broke in half so it couldn't dependent the ice.
I had removed the housing that the drum was in and taken the screws out to get to the broken drum. I removed it there was a set of 6 blades that crushed the ice that had to go back on the same order when I removed these I put them on a piece of wire in the order they came off (so I would get them back I the correct order). Then I reversed the order and reassembled it in the opposite direction . It was fairly easy to do. I'm a 68 year old disabled woman so if I could do it I'm sure you could to. Good luck. It cost me $14.00 if I had bought the whole assembly it would have been $150.00. So it was well worth my time and effort.
Parts Used:
Ice Dispenser Drum
  • ROWENA from WIGGINS, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge side getting warm
Replaced both the thermostat and defrost timer and still froze up and still warm air to the fridge, turned out to be the defrost heater coil. It was cracked in the middle, very easy to test with a multimeter. Replaced the heater coil and all is like new!
Parts Used:
Defrost Thermostat Defrost Timer - 60Hz 120V
  • Benjamin from Mount Vernon, OH
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
8 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!