Charcoal filter needed replaced
Took out the 2 screws holding the front grill on. Took out the old filter and put in the new one. Then put the grill back on...DONE!!!
Parts Used:
Charcoal Filter
  • Carol from Bethel Park, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
change microwave fan discharge from front to top
damper plate was a snap-in part. rotated fan discharge to top of microwave. installed ducting to discharge food odors outside.
Parts Used:
Hood Damper Assembly
  • James from Newbern, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!
When opening door the microwave would turn on.
Watched How to repair a Microwave that turns on when the door is opened Video on the web. From this took a shot at the switch was the problem. When I removed the switch it was defective. The small button was in and when you turned the switch upside down the button would drop back into position. Ordered a switch for $25.oo , installed it and the microwave is working fine.
Parts Used:
Secondary Door Switch
  • Clarence from Rocky Ridge, OH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Bulbs blew and disintegrated when removal was attempted
Unplug appliance, Staring from the rear sides, remove the four side screws. Remove the left and right front screws and finally the front center screw. The bottom panel hinges down toward the rear . Unplug the input wires from the sockets . Unscrew the two retainer screws (one each) and pull the sockets out of the panel. Note that the retainer screws are shouldered. The shoulder fits through the elongated slot in the socket. Screw the bulb into the socket and insert through the mounting hole. Insert and tighten the mounting screws. Note that the sockets may appear to be a bit loose. That's OK because of the shouldered screw. Don't over tighten or you risk stripping the threads of the panel. Plug in the input sockets and install the panel screws in the reverse order of removal. Plug the appliance in and test the bulbs.
Parts Used:
Light Bulb - 40W 130V Light Socket - 250V 75W
  • Richard from Santa Maria, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?