Cracked Housing Mount - water leak
Turned off the water. Removed the maintenance cover plate on the back of the refrigerator and disconnected the tubing. Removed the tubing cover plate on back of refrigerator. Removed two screws from filter hosing mount on the inside of the refrigerator and pulled the old tubing out. Simply inserted the new tubing and mounted the housing and reconnected the tubing using plumber’s pipe compound. Then re-installed the cover plates on the back of the refrigerator, installed the filter and turned on the water. It was a very easy install.
Parts Used:
MWF MANIFOLD
  • Richard from Chandler, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
low water flow from in door water dispenser
after changing the water filter and having no improvement. I went to the next part of the system. Turned off the water supply. I removed the bottom cover in the back of the refrigerator. unscrewed the nuts on the water supply hose from the main supply and the one going back into the fridge. moved to the inside of fridge and unscrewed two screws holding the filter mount and pulled the tubing through. Reversed my steps and the water flow was great . Thanks
Parts Used:
MWF MANIFOLD
  • kevin from summerville, SC
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
17 of 20 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken water line near solonoid to feed drinking water
bought an push in, in line connector and a new 5/16 plastic hose. I just replaces 2 feet of plastic hose from the selonid up an splices the hose using the connector. Worked perfect.
Parts Used:
Plastic Tubing - 5/16 Inch Union Connector - 5/16 Inch to 5/16 Inch
  • Gregory from Yucca Valley, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
20 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer door lever broke
Unscrew the two mounting screws for the plastic vent plate on the bottom of the SS unit and take the remove the vent. Next, slide the end of the lever through the square hole in the bottom bracket and attach the hook end of the lever to one end of the lever spring. Pull on the other end of the lever spring and slip it over the spring mount finger that is a part of the bottom bracket frame. Finally,reattach the plastic vent plate with the 2 mounting screws. Total repair time was less than 15 minutes.
Parts Used:
Freezer Lever - Black
  • James from Jacksonville, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
18 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Frozen water filter and food in fresh food side
Initial diagnosis indicated faulty cold air damper, so first action was to remove the light assembly and then the plastic housing that contains the FF fan and damper. The two hidden screws at base of housing required removal of lower decorative plastic duct that turned to be held by snap in-tabs at top and slide away fastener at bottom. The damper housing is held to the roof of the FF chamber by two screws that were taken out to remove the light assembly.

When the plastic housing is pulled towards the front of the refrigerator, the multi-pin wire connector can be disconnected and the damper assembly easily removed.

Installation required need of a thin plate to seat a sponge rubber seal without damage, so I used a thin metal kitchen spatula. Nothing unexpected was encountered in reversing the disassembly process.

Although the new damper corrected the excessive cold situation, the temperature max-min span remained in excess of 15 degrees F, so the control panel was swapped in the small covered cavity located in the outside back of the refrigerator. A 1/4" nut driver and needle nose pliers were all the tools necessary for this operation.

Together the two replacement components have solved the frozen food problem and the over night max-min FF span is now 5 degrees or less.
Parts Used:
Main Electronic Control Board Air Inlet Cover Kit
  • Herbert from Sunriver, OR
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker supply hose leaking at freezer entrance
I did it the way you recommended except rather than removing the existing tube from the water valve at the bottom of the fridge I cut the existing and new tubes and then spliced the new tube to the old tube. I already had the splicer nut so it was quicker and easier. By the way, shipping was very quick and you prices and your website are excellent!
Parts Used:
Grommet / Tube Assembly
  • Michael from Meridian, MS
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Wrench set
18 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Flapper not sealing. Frost buildup on inside of freezer door
Followed previous instructions from a previous post. Inserted small screwdriver in the 2 outer holes up under the face plate to remove it then removed 4 screws holding the inner assembly which allowed access to the flapper assembly. Replaced it and reassembled everything. Problem solved
Parts Used:
Dispenser Door Assembly or Flapper
  • D from ZELLWOOD, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 16 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
My 13 yr grandson assisted me on this
We couldn't get the other connector loose from one end of the tubing so he said just cut it and so we did and attached the connector. I now have water again in my fridge and took the sticky note down "don't use the water" as it had leaked for a year...... Thanks!
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch
  • Sherry from Auburn Hills, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 17 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
water line leaking behind refigerator
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks
Parts Used:
Union Connector - 5/16 Inch to 5/16 Inch Plastic Tubing - 5/16 Inch
  • Michael from Merrimac, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer freezing up
Unplug refrigerator,remove the freezer bulb, trays and rear cover to expose coils and heating element/defroster, The telltale sign its bad was it looked like an old flashbulb/burned, the old one was open, melt enough ice to remove and replace the defrost element(2 screws 2 wires) and reinstall components, reconnect power, thats it.
Parts Used:
Defrost Heater and Bracket Assembly
  • richard from cleburne, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
16 of 21 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Iced up Freezer compartment in SxS
So I replaced a burnt out defrost heater; replaced the thermostat for good measure and STILL the freezer compartment was freezing up. WHY didn't I look more closely at the ice making system sooner!!?? Thought about it for a while and decided that it had to be that the solenoid in the water valve was NOT shutting off water flow to ice maker (overflowing the icemaker and running over & down interior of freezer compartment making an icberg).

Took off about 4-5 backcover screws with one size nut driver. Moved to a size larger driver to remove 1 screw holding on the water valve. And what some people don't realize is that you can push in the connectors (push them down) and THEN pull the water lines out as long as you're careful and someone hasn't already tugged on the waterlines with some force. You don't have to cut the lines off at the valve. Put the water lines in the new valve and put one screw back in it; then 4-5 backcover screws and you're done!!! At most 15 minutes...that is if you want to clean the condensor unit located behind the backcover (on the newer models within the last 4-6 years).

EASY!!! Do it yourself and save a BUNCH of money. If you're getting a flooded freezer compartment or icebergs created in there then check whenever you hear the icemaker drawing in water and see if water is running down the interior.....problem solved!
Parts Used:
WATER VALVE WITH GUARD
  • Jamison from Heltonville, IN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Condenser Fan Motor stopped turning
1. Unplugged the fridge. 2. unplugged the fan connection and removed the wire holding clip. 3. removed the 2 screws holding the motor bracket in place and removed the bracket. 4. Pulled gently back on the motor so that the fan pressed against the front bracket until the fan slid off the motor shaft. 5. Pulled the rubber motor mounts off of the old motor and placed on the new motor. 6. Slide the new motor in place pressed the fan all the way onto the shaft. 7. Placed the rear motor bracket in place and started the screws by hand making sure the ground wire was attached to the furthest away screw. 8. tightened the screws down. 9. Pushed in the wire holding clip into the clip hole. 10. Plugged back in the fan. 11. Plugged back in the fridge. 12. Turned down the temp on the fridge to kick on the compressor and checked to assure the fan was operating and then set the temp back to normal. 13. Vacuumed the condenser coils to get them all clean and ready for more years of service!
Parts Used:
Condenser Fan Motor
  • Arthur from Alamosa, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Socket set
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No longer needed water filters
Your website was very easy to use and the product shipped very promptly. It was great experience. Thanks!
Parts Used:
MWF BYPASS
  • Jeffrey from Williamsburg, VA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Helix was free wheeling in the ice maker
Helix plate keyed hole was stripped keeping the helix from rotating with the auger. I bought an auger too, but didn't need it as the auger is a harder material than the helix plate and was not worn where the plate contacts it. TAKE PICTURES of the dispenser blades area before taking them off the auger shaft.
Parts Used:
Plate - Helix Lock Helix Helix Auger
  • Terrence J from Wheatland, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
18 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker not making ice
just unscrewed the 3 screws, attached the rounded plug that came with the unit and screwed back only 2 screws. ice magic in about a couple of hours
Parts Used:
Ice Maker
  • Cristina from Los Angeles, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
16 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the DSS25KSRDSS