Dryer ran but would not heat
PartSelect showed seven different possibilities why the dryer wouldn't heat. I removed the two screws to remove the bottom panel and turned the dryer on and noticed that the heating element that ignites the gas was working fine. This meant that it was not getting gas so it could be the gas valve or one of the two gas valve coils which are located on top of the gas valve. I borrowed my neighbor"s ohm meter and touched the two probes on the coils terminals to check for continuity and found that one of the coils read zero. I then took both of the coils out by removing two screws and tested each coil again. One coil read 500-850 and the other read zero. This meant that it was no good so I called for the part and received it in three days. I reassembled the parts and turned the dryer on and it fired up after a few seconds. It works as good as new. The part plus shipping was less than $30. My repairman would have charged me $150-$200. While the dryer was apart I gave it a good cleaning with a vacuum and a toothbrush in delicate areas. I also removed and cleaned the lint trap housing by removing two nuts. I didn't know much about gas dryers, but thanks to PartSelect I easily fixed it myself.
Parts Used:
M Series New Style Coil Kit
  • Gary from Haverhill, NH
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
390 of 439 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer flame goes out after about 8-minutes from start and won’t work again until a 15-minute rest.
There was no problem with lint build-up within the dryer & the exhaust vent. I removed the gas cycling thermostat & thermal fuse from system & dryer still was not operating correctly. The radiant sensor & hi-limit thermostat both seemed to be operating correctly. That left either of the two coils as the culprits. I replaced both coils & the problem was corrected.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • andy from Bethesda, MD
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
202 of 224 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer belt broke
first I took the dryer apart 1st thing i did was unplug the power supply (safety first) then I removed the top of the unit then removed the front cleaned all the lint from the inside of the cabinet I found the proper belt size on part select.com the next day I had my dryer belt delivered (which cost 1/3 the price of the local repair shop price)
then I placed the belt over the dryer drum and made sure it was in the general location it should be I then replaced the front cover and the top. then I removed the rear cover which was held on by six 5/16 sheet metal screws which gave me access to the drive pulley and belt tensioner the belt goes on by going under the tensioner then around the drive pulley
Then i rotated the drum by hand to make sure everything had clearance I then buttend everything up plugged it and started it up it workd fine and I figure Ill get another 8 years out of it
Thank you partselect.com
Parts Used:
Drive Belt
  • Matt from La Belle, MO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
160 of 188 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Timer wasn't working (New Timer)
Timer wasn't working on the regular cycle so I replace it with a new one from partselect. It still wasn't working so I ordered and replace the cycling thermostat, the thermal fuse I also cleaned the vent and dryer it still didn't work so I read the diagram for the electrical and found that a coil for the gas valve is line with timer. I ordered the coils for the valves, replaced both valves and tested the dryer and it work just like when I first bought the appliance.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Joaquin from Las Vegas, NV
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
158 of 198 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Extended drying time. Some but not enough heat. Burner would light for 15-18 seconds at first then shut off for 1-3 minutes then light for 3-6 seconds and repeat for the length of the cycle.
Determining the problem was the hardest part. With multiple parts (coils,thermostats...)possibly causing similar symptoms, I narrowed it down to the two coil valves.
Un plug the dryer. Remove two screws at the base of the front panel. Turn the front panel 180 degrees to avoid disconnecting the door switch. Gas valve with coils on top are on the right in front. Remove two screws in bracket holding coils, disconnect the wires, replace with new coils and reconnect wires. One coil has 2 terminals the other has 3 no chance of crossing the wires. I used an offset/right angle screw driver for one of the bracket screws due to close proximity to the drum. A stubby phillips head will work. You can check the burner operation with the front panel off as long as the door switch is still attached. Swing the front panel around and lift back into place securing with the two screws. Dryer works fine now.
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Matthew from Lake Worth, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
120 of 138 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would only heat cycle once
I removed the two screws holding the front panel to expose the lower works and verified the heating cycle failure. After a check of the vent system, checking the sensors for continuity and coils for resistance, I retired to the 'net for support. Accepting the general consensus that the most frequent, common and likely failure to be the coils, I rechecked them with the meter and found the two pronged coil to have significantly more resistance than the three prong coil. That was enough evidence to point to the coils. While I waited for the part to arrive, I replace the vent ducting. When the parts arrived I removed the two Phillips screws holding the coils, removed the old ones, installed the new ones, replaced the bracket, put the front cover back on and in less then ten minutes clothes where drying.
Parts Used:
M Series New Style Coil Kit
  • Robert from Seattle, WA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
80 of 89 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer would heat initially, but would not heat throughout entire cycle.
-Removed top panel
-Removed right side panel
-Gas coils were held in together under a metal strap
-Removed 2 screws holding strap
-Unplugged 1 wire harness to each coil
-Removed Primary and Holding coil
-Replace with two new coils, replace strap and plug in each harness
-Replace side, then top panel
-Under 1 hour job...Took 45 minutes to remove/replace panels and only 5 minutes to replace coils.
-Anyone with a little mechanical ability can save $150 in labor and spend just $50 in parts to fix this problem.
-Questions: Erik at elstransport13@gmail.com
Parts Used:
M - Series Secondary Coil - 2 Terminals M-Series Primary Dual Coil Gas Valve
  • Erik from Newport, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
74 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer heated up for a few minutes and then cooled down.
1 Unplug power.
2. Remove the front of the unit by removing the two screws at the bottom of the front panel. Front dryer panel will swing out from the bottom and then the clips will release the top of the panel, careful not to disconnect the dryer door switch. ( can be unplugged to remove the front panel out of the way.)
3. Looking inside the unit on the right side you will see the gas value. On top of the gas unit you will see two small coils the coil closest to the burner has two leads on it. Remove the two screws to get to the coils, remove the medal plate, remove the connector then lift off the secondary coil. Replace and test. You can test unit with the front panel off. (be careful). If no heat, check that the Flat Style igniter is glowing. (ohm out both coils) before ordering parts. Intermittent heat problems. I replaced the secondary coil, it did ohm out o:k but it had swollen and was very tight on the shaft.
Parts Used:
M Series New Style Coil Kit
  • James from Limington, ME
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
65 of 73 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The dryer would start to heat then the heat would stop
I changed out the cycling thermostat and the high limit thermostat. Mainly because that was what my research indicated was the problem. I then found some more information online that indicated the gas solenoid valves were bad. I ordered them from you and replaced them. The problem was fixed.

In order to replace the valves you need to remove the top panel. Two screws at the top of the front door assembly hold it on. Remove the screws, lift up on the front panel door assembly and move it to the side. The drum will rest in place. In the lower left corner, under the drum, you will see the solenoids. Two screws attach a plate that holds down the solenoids. Take the hold down plate off, disconnect the control wires attached to the solenoids and lift out the solenoid/control valves. To assemble everything, work backwards to the start. Good Luck
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Theodore from Riverside, CA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
56 of 66 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
belt broken, pulley worn out
Removed 4 screws from top of control panel , remove 2 from back to lossen top of dryer. Removed rear lower access cover,6 screws on back of dryer exposing pulley and tensioner, remove broken belt and vaccuumed out a ton of lint , removed pulley and tensioner and replaced. From the front remove 4 screws and take off front of dryer, disconnecting several wires, again vaccumed out lint, lifter drum evough to replace belt. Reassembled
Parts Used:
Idler Pulley Wheel
  • Anthony from Mpls, MN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Socket set
68 of 102 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Dryer made excessively loud noise when running.
I initially opened the front of the dryer and noticed that the drum slides that the drum rides on in the front of the dryer were excessively worn. I then removed the drum and noticed that the plastic bearing that supported the drum in the rear was cracked and the washer(?) appered to be disintigrating. I ordered and replaced the drum slides and rear bearing. The dryer was still making too much noise. I ran the motor with the drum removed and realized that they motor was the remaining source of the excessive noise. I then ordered and replaced the motor with a new one and this solved the problem. Total cost was around $140. Note that when ordering a new motor, the instructions on the web site indicate that you need to order the motor pulley if your existing motor has a pressed on pulley. The new motor was a kit that came with the pulley included, and therefore the additional part was not needed, and had to be returned. The instructional videos and parts schematics on the web site were very helpful.
Parts Used:
Drive Motor Motor Pulley with Screws
  • Owen from Virginia Beach, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers, Socket set, Wrench (Adjustable)
58 of 76 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer would get hot for a while, then quit heating
After reading about other people with this same problem I took a chance that this would be what was wrong with my dryer.I took off the front cover of the dryer by removing two screws. I located the faulty coils and simply plugged in the 2 new coils Tah-dah Probably coud have been done without even removing the front panel, but since it was off I vacuumed out the lint ( actually my husband did all of the above, but I tell a better tale than he does and I diagnosed the problem and ordered theparts)
Parts Used:
M Series New Style Coil Kit M Series New Style Coil Kit
  • Sharon from Houston, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
54 of 66 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Intermittent or no gas ignition, HSI ignightor working
Removed front of gas dryer and cleaned all lint out. Checked HSI, and cleaned flame sensor. Split (3 terminal) gas coil terminals were intermittent. Read about 700 ohms across outer two terminals, but center terminal to either outer terminal was open (Infiniti on meter) 2 terminal coil measured about 550 ohms. 3 terminal coil should read about 700 ohms across outer terminals, and about 1.5K ohms center to outer terminals. Unscrewed index cover plate and replaced coil, 2 terminal coil was okay. Reassembled and finished 12 loads of laundry no problems at all.
Parts Used:
M Series New Style Coil Kit
  • Steven from Sauk Village, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
43 of 48 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
dryer would not get hot after igniter went on, no gas being let in.
Removed top cover of dryer with screwdiver 2 screws, removed front cover 2 small bolts with 5/16 scoket. Removed coil brackets with shor screwdriver replace coils as ness. and put covers back on and works great!

Vinny
Parts Used:
M - Series Secondary Coil - 2 Terminals M-Series Primary Dual Coil Gas Valve
  • Vinny from Port Chester, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Socket set
46 of 58 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Gas burner would not ignite
(I knew the gas coils were bad, since the gas ignitor would glow brightly as the burner attempted to ignite. So I knew everything except the gas valve was operating normally.)

Unplug the electrical cord to the dryer. Remove the front access panel. Remove the retainer clip for the gas coils (2 screws). Remove the coils and unplug the electrical connections. Connect the new coils to their respective electricl connections. Slide the nes coils back onto their respective posts on the gas valve. Replace the retainer clip, and 2 screws to hold it in place. (I then plugged the dryer back into the wall outlet to visually check the burner operation) Everything worked fine so I then replaced the front panel.
Parts Used:
M Series New Style Coil Kit
  • Jack from Conroe, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Wrench set
36 of 40 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!