water line leaking behind refigerator

  • Customer: Michael from Merrimac, MA
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Pliers
  • 12 of 13 people found this instruction helpful
Plastic water line gets brittle from compersor heat over time and eventually brakes. I tried to fix with 5/16 line from a locel hardware store but outter diameter was slightly smaller so connection to valve leaked. This OEM part fit perfect. I cut the line beyond the brake and connected it with the tube union part, Easy fix. Everything works fine with no leaks

Cams On Freezer Door Broke

  • Customer: WALTER from FROSTBURG, MD
  • Difficulty: A Bit Difficult
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Socket set, Wrench (Adjustable)
  • 12 of 13 people found this instruction helpful
Removed top hinge and electrical connector (freezer door has ice and water dispensers) then had to turn off water supply to unit and disconnect the hose to the door and remove the spring protector from the hose -- this required removal of the compression fittings in the water line so spring would come off of the tube. Then removed bottom hinge from the door and used saw to remove the rivet that had held the cam to the hinge, used a nut and bolt to attach new cam. Put other cam (used two) in the hinge and replaced lower hinge unit on the door. Then reattached both hinges to the refrigerator and lined up the door put the spring protector and compression fittings back on plastic tubing and reconnected the water supply and electric fitting, turned on water to unit and prayed there were no leaks. Prayer was answered, the water dispenser worked properly and the ice maker filled with water so I then replaced the hinge cover on top of the unit and the grill at the bottom and had a pepsi. A few years ago I had replaced the cams on the other door which had no water/electic connections and was a much simpler job.

ice would not dispense

  • Customer: john from montgomery, TX
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers, Socket set
  • 13 of 17 people found this instruction helpful
I removed 6 screws, unplugged assembly that had motor attached,removed from fridg,replaced motor and reinstalled assembly, putting back 6 screws.works like new.
thanks.

freezer freezing, refrig warm

  • Customer: Tom from Schofield, WI
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Screw drivers
  • 13 of 17 people found this instruction helpful
pretty straight forward,removed threw screws to replace the defrost timer and reverse the procedure. To replace the defrost unit 1st removed metal back plate in freezer. Step 2 defrost freezer. step 3 remove four screws that hold defrost elements in freezer compartment. Step 4 install new defrost elements and secure back in place with four screws. step 5 optional read old defrost heaters with ohm meter to confirm the defective part. step 6 plug back in frig and enjoy a cool brewski ahhhhh. By the way only one defrost element was bad (open) but as mentioned in literature which came with new derost elements I replaced both of them. Thanks again for all the help on this, saved me $2000 on a new frig.

Compressor overheating - Fridge not Cooling

  • Customer: CHRIS from LAGUNA NIGUEL, CA
  • Difficulty: Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 12 of 15 people found this instruction helpful
Condensor Fan not turning. I thought it would be an easy fix. I thought I could pull off the shroud and fan assy - no joy. Too many copper pipes and lots of tubing in the way. It took 90 minutes to remove and 30 minutes to install. The BIG hint here is to loosen the shoud, pull it back as far as you can and then remove the nut that holds the fan blade in place. THEN you can remove the motor. Get the new motor back into the shroud, get the blade back on and then tighten the shroud back up.

This part on refrigerator went out, wouldn't dispense water.

  • Customer: Glen from Harrisburg, OR
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers
  • 13 of 18 people found this instruction helpful
I removed the back cover on the refrigerator. Unbolted the unit. First of all I unpluged the refrigerator. Took off the two electrical connections and removed the input and output water lines. I then reversed this process when I installed the new part. It was real easy.

Frig would stop working every so often. Lots of food got spoiled.

  • Customer: Rene from Bronx, NY
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 11 of 12 people found this instruction helpful
Got part overnight. Unscrewed cover plate at top of regerator compartment, disconnected old part, connected new part. Screwed back plate. Voila!

I saved a bunch of money!

Replace Dual Inlet Water Valve

  • Customer: Timothy from West Windsor, NJ
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Pliers, Screw drivers, Wrench set
  • 16 of 27 people found this instruction helpful
Unplug the electrical power to the refridgerator, remove old valve, marking which electrical wire set goes to which solenoid valve. Cut the nut fasteners from the ice maker and front door water tubes. Leave the nut fastener on the supply line.

New valve - remove plastic shipping protection guard, remove rubber cap from supply connection, bend mounting bracket to a 90 degree bend, attach electrical wire reducers to the small wattage solenoid wires then to the solenoid, attach large wattage solenoid wires to the large solenoid, push ice maker tube into the small quick-connection(no nut fastener needed), push the front door water into the large quick-connection, finally mount valve asembly using same holes in frame as held the old valve assembly. Plug in the power. Solenoid valves may take an hour or so to operate.

Ice maker ot making ice

  • Customer: Barry from Phoenix, AZ
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 14 of 22 people found this instruction helpful
First I replaced the double valve because the ice maker was not filling with water. It still did not work. Then I replaced the ice maker itself. This worked and was relatively easy to replace. I had to use the water fill "slide" from the old ice maker. The new one was too narrow and it leaked water into the freezer.

Water and Ice acuator had a hole in it. Need to be replaced.

  • Customer: Lowell H from Gilbert, AZ
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required:
  • 11 of 13 people found this instruction helpful
Used my fingers and pulled the old one our and pressec the new one in all in about 30 seconds. Saved at least a $60 service call.

Door hinge cam crumbled

  • Customer: Ralph from Portland, OR
  • Difficulty: Really Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 11 of 13 people found this instruction helpful
Simple job, empty the door shelves, remove top hinge, lift door off bottom hinge, remove bottom hing. The reassembly is the reverse, with a little cleaning along the way and a little white lithium grease on the hinge pins and cams.

replace icemaker

  • Customer: Conrad from Oglesby, IL
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 11 of 13 people found this instruction helpful
I slid the old ice maker (which was rusty) out of the freezer. I emptied the ice cubes. I unscrewed the 3 screws holding the plate to the old ice maker. I attached the original plate to the new ice maker/ auger unit with 2 screws. The new icemaker assembly did not match up with a 3rd screw hole. The 2 screws seem to be holding securely.
I reinserted the new assembly. Shorly after this nice clean ice cubes began to form. Works very well!

Refrigerator Door Wouldn't Close Right

  • Customer: Anthony from Highland Lakes, NJ
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Screw drivers, Wrench set
  • 12 of 16 people found this instruction helpful
Get 2 "door closing cams" yep. Same as some others here. Found some black plastic pieces on the floor, when door wasn't closing right. I took the door off by taking off the top bracket. Very easy. Bottom bracket has the broken cam riveted to it. Need hacksaw to get this off then punch it through with hammer and a screwdriver. This is the only part that took a little while. Replace the closing cam and find a small nut & bolt or screw to replace the rivet you just sawed in half. Replace the closing cam that is on the bottom the the door as well. Even if yours isn't broken. Replace it anyway. Put door back on and done. Not a diffucult project if you know about the rivet and needing 2 closing cams beforehand. Good luck

Motor rattled loudly

  • Customer: Robert from Kingwood, TX
  • Difficulty: Really Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 11 of 13 people found this instruction helpful
Turned off the refridgerator. Took everything out of the freezer compartment & put into ice chest with pleanty of ice on top. Removed 2 screws holding the ice maker in place & placed ice maker aside. Removed shelf. Removed one screw on back plate, pushed up on the holding tabs at the top of the back plate & removed the back plate. Removed 3 screws holding the motor bracket in place along with the 3 wires. Installed new motor & used the wire extensions provided due to the electrical connections on the new motor being on the opposite side. Had to bend one wire tab down to clear the motor bracket. Turned refridgerator back on to ensure correct rotation on the fan. Reinstalled back plate & ice maker & shelf. Waited 30 minutes before putting food items back in freezer compartment.

Defrost Thermostat quit working

  • Customer: Jimmy from Palmer, TN
  • Difficulty: Really Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 11 of 13 people found this instruction helpful
Take the back panel off inside of freezer side. Cut the wires off old Defrost Thermostat and strip the ends. Attach the wires of the new one and tighten with wire nuts. Put back panel back on.