I followed the instructions They worked well, but there are two things I should mention. Once I removed the inside panel of the door (with shelving for jars, etc.) to get to the gasket I found the insulation behind it to be encased in ice. I had to replace the insulation. Then, when I had it back together and closed the door there were large gaps between the new gasket and the body of the freezer. I tried various things to fix it and finally found that by pushing hard of the door with the freezer running it pretty well sealed. After running for a while it sealed completely and has been working perfectly since.
Freezer wouldn’t cool; ice buildup stopped the fan
The defrost circuit is relatively simple. Just three components and interconnecting wiring. Ensure the timer works first, then check the heater element for continuity. Lastly i jumpered around the temp switch to eliminate interconnecting wiring. You can test the switch by cooling it to see if it opens, but some do not open like the one in this particular Whirlpool until they are well below freezing so you’ll need to take that into account in your troubleshooting. Replacing the switch itself is very simple, it’s two wires and it just clips to the heat exchanger in the back of the freezer behind a metal cover.
Light switch wasn't working.. As I would close the door I would notice our frig light wasn't going off...
I simply removed the old switch by gently pulling down on the old switch with a screwdriver. When it was about half way out I just gently pulled down on the old switch and it popped out... I removed the two connectors attached to the old switch by pulling on the connectors with a pliers...I tried using my fingers but wasn't able to pull the connectors off so I used pliers. It worked perfectly.. When pulling off the old connectors, make sure you attach the new switch to the same tabs on the new switch... It was very easy to do and took under 5 mins.....The light switch works perfect....P.S. You should unplug the frig while making the connection just in case....Safety first....!!!
inserted a knife between the switch and the plastic interior in order to pop the switch out. then took off the 2 wires on the old switch put them on the new switch and reinserted the switch into the plastic interior.
Taking the hub out was a promblem because, with a puller it did not come out. It broke off while pulling out we had to drill it out had to brake off.You need a 1 1/2 inch deep socket with a impact wrench. It was a hassel but got done. I replaced the whole seal kit and it is still leaking it leaks from the bottom of the tub. It leaks worse when it has a heavy load I dont know what to do.Need help.
The light rocker switch wasnt working. I found the part on the web site. It was so easy. I used a screw driver to pop out the old one and pop the new one in. It took 5 min. Thanks!!!
Door gasket not sealing allowing ice/ frost to form around and inside the door.
It was easy to take the door off by taking the two screws (located on the top of the freezer) off the top hinge and lift the door up off the bottom hinge. I took it outside and laid it on a table. Removed all the screws and took off the panel so I could remove the old gasket and clean the door and panel. The inside of the door was full of ice so we removed that and the insulation which I replaced. My wife then put the new gasket in the dryer on medium temp for about 5 minutes. We slipped the new gasket on the panel and lined it up on the door and screwed it back on the door. Then we put it back onto the freezer bottom first then replaced two screws on top hinge. Shut the door and use a blow dryer on the gasket with the door closed to make the gasket seal / conform to the door/freezer until there are no gaps between the gasket and the freezer. Note: Once the ice and water are out of the door the door doesn't weigh nearly as much as it did. Also
changed the light bulb still would not work so I figured it was the switch sure enough.
I took a chance and ordered a switch that is next to the top of the door. looked for how to remove it easily done in ten minutes works fine last long time.
****Make are you order Capacitor & Starter relay too (we ordered separtely so had to pay shipping twice)**** Super easy just open access panel on back near compressor and remove retention clip with fingers, remove & replace both capacitor & starter, put clip and access panel back on, plug in and allow 8 hours to cool! Works like new again! Hope it goes another 10 years
Ordered the leveling bolts, very fast shipping, parts correct as shown. Purchased a condo by the shore, frige had no levelers, they went in smoothly & was done in no time. Steve