inlet valve leaked water after installation
The ice maker was easy but the older Maytag inlet valves are rigid plastic line- make sure that line is properly connected to back of fridge- the 1st night the water leaked down back of freeze- thus no ice in ice maker tray ----but the bottom of freezer was full of frozen water--- took ice maker off and realigned inlet pipe- once that was done- no more problems- ( did also have to take hair dryer and remove all ice build up in bottom of freezer --- remember to check that rigid line as it can become detached while changing out ice maker assembly- thx Greg
Parts Used:
Replacement Ice Maker
  • Greg from Gold Canyon, AZ