Would not freeze or defrost
Unplug freezer let stand all night to defrost. Remove the tray cover which is located on the upper back area inside the freezer.( 3 twist fittings remove it ). Remove the upper stainless steel panel which is secured with 6 screws. This will drop down exposing the condenser. Note all the wires and fan will stay attached to the stainless steel panel, this panel will drop down no need to unplug anything. On the left upper side next to the condenser you will see the thermostat. Two color coded wires. Remove the thermostat and install the new one at the same location.
Parts Used:
Defrost Thermostat
  • RONALD from Sevierville, TN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer was no longer keeping items frozen,
I followed the You-Tube instructions, removed the ice from the compressor and replaced the thermostat with the part I received from Part Select. What I took out was a part that was very much inferior to the replacement part. The repair saved me a lot of money for a new freezer and it was not difficult to do following the video. Now the freezer runs better and quieter than ever. Thank you Parts Select.
Parts Used:
Defrost Thermostat
  • Philippa from New York, NY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Coils not Defrosting and stopped freezing
Upluged power pulled freezer out from wall removed the two screws that holds the defrost timer unpluged defrost timer pluged new timer in mounted new timer back with the two screws pluged freezer back in and job was complete. Freezer working fine.
Parts Used:
DEFROST TIMER
  • Joseph from Yulee, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
coils would freeze over not allowing air to circulate throughout freezer
replace thermostat and timer after defrosting and cleaning out freezer. I took less than 10 minutes and now freezer has a defrost cycle that eliminates frost buildup on the coils.
Parts Used:
DEFROST TIMER Defrost Thermostat
  • robert from royal oaks, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer would not keep running and the temperature was too warm.
Followed the sites instructions. Empty the bottom part of the freezer. Remove the screws. Move the panel out of the way. Easily remove the old part and replace with the new. Put the panel and screws back in place. The freezer works.
Parts Used:
Defrost Thermostat
  • Edmond from Carroll, NH
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Side rail for sliding shelf would not stay tight
The sliding shelf side rail is held by three philips head screws that tighten into nut inserts. No amount of tightening would keep two of the three screws tight. I found that the nut inserts which are plastic and insert into the side of the freezer would pull loose, probably from years of overloading the sliding shelf basket. Ordered two nut inserts from PartSelect. 1. Remove three screws to remove shelf slide side rail. 2. Remove nut inserts to be replaced with needle nose pliers or reinsert screw a couple of turns and pull nut insert out with pliers. 3. Insert new nut inserts, position side rail, and tighten screws. Replace sliding shelf/basket.
Parts Used:
Nut Insert
  • Scott J from Westminster, CO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
Was this instruction helpful to you?
Thank you for voting!
condenser fan stop working
Replaced fan. I ordered the fan and received it the following.(-:
Parts Used:
FAN MOTOR EVAP 115V
  • George from Gilroy, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers, Socket set
Was this instruction helpful to you?
Thank you for voting!
Freezer would constantly run. Even when it was super cold inside.
I ordered a new thermostat and installed it in less than 15 minutes. Looks like the problem is fixed. Now ,the freezer cycles on and off correctly. The part was ordered on a Monday and I got it the next day. I am very satisfied.
Parts Used:
Defrost Thermostat
  • David from San Marcos, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
Freezer ran alot, then temperture began to vary.
Watched video on Part Select which shows you how to replace the thermostat with several good pointers. Very easily done and now the freezer works great.
Parts Used:
Defrost Thermostat
  • John from Port Republic, VA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the AFFU1766DW5