The evap motor failed (no air movement inside of refrierater
Removed screws from cover tested for power to motor found power was on to motor but motor did not work. I went to your web site was able to locate part in about 5 minutes . Even with over night shipping the part came to about $50,00, far cheaper tha a service call would have been.

Thanks John Paulsell
Parts Used:
Freezer Evaporator Fan Motor - 115V 60Hz
  • John from Flagstaff, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
28 of 35 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Broken Crisper Rail
Removed the drawers and shelf unit above the shelves. Installed the new rail and put the shelf unit and drawers back in. Less than 5 minute repair. Very fast delivery of part and reasonable pricing.
Parts Used:
Refrigerator Center Crisper Drawer Slide Rail - White
  • Linda from Turner, MT
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
24 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice in ice maker
Turn water and refrigerator off, use hair to thaw the ice maker filler tube, then remove the filler tube inside the freezer. Next remove the water supply line cover plate in back of the refrigerator. Now remove the speed clip at the white pvc elbow and pull out the supply line. Next, grasp the pvc elbow with pliers and pull hard to remove. The new filler tube is a 1 piece design (filler tube and elbow combined) and needs to be cut to the proper length. Mark it inside the freezer, remove it and cut to length. Now coat the outside flange with caulk or PU glue and snap into the opening. Put the speed clip on the elbow first and center it. Ensure that the spreader insert is in place in the plastic tube, then slide the supply line into the elbow untill completely engaged. Replace cover.
Parts Used:
Refrigerator Ice Maker Fill Tube Speed Clamp Clip Plastic Tube Insert
  • Dave from dunwoody, GA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
28 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was freezing most products
Remove the light cover. Use a flat head screw driver to push in the tabs on the back of the program mount and pull down to expose the computer board. The Thermistor is clipped on under the vent holes on the right side. Cut both wires to remove the old thermistor strip a 1/4 inch off the remaning wires and the new thermistor wires twist both ends together crimp on the wire caps snap in the new thermistor reinstall the program board until the retainer clips snap into place, slide the light cover back on.
Parts Used:
Thermistor
  • michael from MARION, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
25 of 28 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was leaking water and causing the ice to freeze into a block
First I removed the Ice bin, I then loosened the ice bin rail under the ice maker and removed the screw that attached the bottom of the ice maker to the side of the fridge. I unplugged the power to Ice Maker from the back of the fridge and unscreewed the two screws that secured the ice maker to the fridge. This allowed the Ice Maker to be removed from the fridge. To replace the new ice maker I simply repeated the steps in reverse.
Parts Used:
Replacement Ice Maker
  • Shelley from Katy, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
30 of 47 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Icemaker leaked water into ice bin causing a glob of ice
Philips head screwdriver and ten minutes was all it took! I removed the two screws that hold the icemaker assembly in place, then pulled it out a little and disconnected the electrical plug freeing the icemaker assembly. Then I snapped the external parts off my old icemaker assembly and snapped them on the new icemaker assembly. Installing the new icemaker assembly was just as fast and easy. I snapped the electrical plug into the new icemaker assembly, then screwed in the two screws. It was making ice shortly thereafter. Glob free ice! I'm glad I didn't call a repairman. I probably saved a hundred bucks. A ten year old could accomplish this simple and easy task. No wonder the Maytag repairman has time on his hands.
Parts Used:
Replacement Ice Maker
  • Kevin from Tyler, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
22 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Periodic loud buzzing noise from frig damper unit
Unsnap damper louver cover using only your fingernails at bottom. Remove two phillips screws from damper cover. Remove styrofoam molded insulation. Squeeze electrical connector to release latch; unplug connector. Release latches on both sides of damper control while gently pulling on damper control unit to remove it. Install new unit by doing above steps in reverse. Damper door may move when electrics connected; keep fingers clear.
Amana would not honor our extended warranty that we paid $65 for, saying that noises are not covered. Im glad that Partselect supplied the part quick and and a great price. The frig is quiet for the first time in 2 years!
Parts Used:
Damper Control Assembly
  • James from Oconomowoc, WI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
24 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water leaking from Water Inlet Valve
Ok, pretty easy repair when the parts are correct (first part was faulty, parts select quickly sent me a new one)

First is removal, these tubes are in there very tight, they can be pulled out but weaken the lines and it is not likely to work without severly stretching the line to the point of breakage, if you have to cut them do so carefully and take off as little tubing as possible as you need the length to feed from top to bottom.

Once you have cut all the lines, or pulled them out (I was able to get 2 out without cutting) then make sure the edges are smooth, attach the inlet valve to the plate and just push them tightly into the new valve making sure you route the lines correctly.

Turn everything on and run the water line to see if it works. If no leaks, screw it back to the refrigerator and you are good to go. Takes maybe 20 minutes at most.
Parts Used:
Dual Water Inlet Valve
  • Brian from Easton, PA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
22 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Noisy Control
Remove cover inside frig at rearwall top with screw driver. Remove phillips screws holding unit in place. Unclip connectors ,and replace in reverse order.
Parts Used:
Damper Control Assembly
  • Nicholas from Agawam, MA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
20 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker broke at the begining of summer !!!!!!
The new Ice Maker Assembly arived in less than 24 hours. I was amazed that it came so fast.

I had already removed the old ice maker in order to get the modle number.

I just took two parts off of the old ice maker and quickly snapped them into place on the new ice maker. Then attached it to the refrigerator in less than 10 minutes. With in a few hours I had ice again !!!!!

I would definatly use partselect.com again.
Parts Used:
Replacement Ice Maker
  • Darrell from Pepperell, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
20 of 24 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
replace plastic wheels on refridgerator
I used board levers to do one side at a time.Kinda tricky, but you can hoist up fridge high enough to replace wheels. take your time think it out and be safe . Make sure you use saftey boards to support load to protect yourself==good luck A small mirror may help to see how the rollers alien in the supports.
Parts Used:
Single Wheel Assembly
  • robert from oak forest, IL
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Socket set
24 of 36 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
very noisy intermittently
Inside the food section above the top shelf behind the light in the back, remove the lid from the cover in lifting from the lower edge no tools necessary here. Remove two screws with Phillips screw driver remove entire housing inclusive Styrofoam insert. Unplug damper Control Unit. Remove two screws and remove damper control unit and replace in reverse order. Finally that refrigerator is quiet, I should have done this long time ago. Unbelievable this is the second part I have to replace on this expensive refrigerator.
Parts Used:
Damper Control Assembly
  • klaus from san diego, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
20 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator wouldn't get cold enough.
Freezer would get cold at bottom and some of the refrigerator. Took of freezer back panel and located freezer fan. Took a meter and saw power was getting to it, but not working. Removed fan and replaced with new on, working like a charm. Cold air was not circulating enough throughout the unit because fan was not working. It was not the thermostat or adapter control.
Parts Used:
Freezer Evaporator Fan Motor - 115V 60Hz
  • Ty from Wentzville, MO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
20 of 26 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The compressor would try to start,but would not.
I pulled the whole unit(condenser&overload relay)
with my hand & disconnected the wire connected
to it & Replaced it with the new one.Peace of cake.
Parts Used:
Compressor Start Device and Capacitor
  • Alfred from Port Charlotte, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
18 of 22 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water began to leak under the refrigerator. Source looked like it was coming from control valve suppling water to ice maker and water dispenser.
Followed instructions supplied. It was relatively easy and the parts fit exactly right. Sears wanted twice as much for the part and service would have charged me another $100 to come to my home. I saved over $100 doing the project myself.
Parts Used:
Water Tube Kit
  • jesse from hacienda heights, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
21 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the ABR2222FES