Fridge got warm and freezer coils were frosted

  • Customer: Stephen from Warrington PA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver, Pliers, Screw drivers
  • 213 of 247 people found this instruction helpful
Fridge is a side by side. The freezer is pretty narrow for a guy with wide shoulders.

Pulled plug.

Had to remove bottom drawers then used nut driver to remove screws closest to back wall in drawer runners. Once the back screws were removed the runners could be swung up or down out of way so back cover could be removed.

Once back cover was removed thermostat was located attached to top pipe going into coil using a spring clamp.

Cut the wires just outside the crimp connectors going into thermostat. Released the spring clamp buy squeezing botton together.

Removed old badly corroded thermostat.

I wish I had attached the crimp connectors to the new thermostat wires before mounting it. Reaching way in the back, while turning shoulders verticly and trying to get the wire connectors set from both sides was awkward and uncomfortable...The biggest PIA of the whole task.

Once connected I let the fridge (thermostat) cool for 10 min. Turned the dial defrost timer to get it into defrost mode. Stupidly touched the heating element to see if it was getting warm...it was very hot.

Coils steamed...every looked like it was working. Unplugged, put back cover back on and retattached drawer mounts.

Plugged back in and everying is working great!

ICE MAKER STOPPED WORKING

  • Customer: JACK from MESA AZ
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Screw drivers
  • 84 of 90 people found this instruction helpful
IT WAS PRETTY STRAIGHT FORWARD. REMOVE THE TWO SCREWS THAT HOLD THE UNIT TO THE WALL OF THE FREEZER. IN MY CASE, I HAD TO USE A DIFFERENT ICE MAKER THAN WHAT CAME WITH THE FRIG. IN ORDER TO INSTALL THE REPLACEMENT UNIT THEY SENT A WIRE ADAPTOR SO IT WOULD ATTACH TO THE EXISTING WIRING. THAT TOO WAS ALL FINE AND DANDY. THE ONLY PROBLEM WAS THAT THE END OF THE WIRE ADAPTOR DID NOT FIT THROUGH THE EXISTING HOLE IN THE REAR OF THE FRIG. I USED A UTILITY KNIFE TO CUT THROUGH THE THIN METAL LINING. THAT WORKED JUST FINE. HOWEVER, I COULD NOT CUT THROUGH THE INSULATION BECAUSE I COULD NOT REACH IT THROUGH THE SMALL HOLE. THE EXCESS WIRE WAS SUPPOSED TO BE PULLED THROUGH THE HOLE AND OUT THROUGH THE BACK OF THE UNIT. SO NOW THE EXCESS IS BETWEEN THE WALL OF THE FREEZER AND THE INSULATION.
THE UNIT IS WORKING WONDERFULLY. IN FACT, IT IS MAKING MORE ICE THAN I CAN USE. I AM VERY PLEASED WITH THE REPLACEMENT UNIT. THIS IS THE 3RD ICE MAKER THAT HAS BEEN IN THIS FRIG. ALL THE OTHERS HAD A DESIGN FLAW THAT HAD A LEAK IN THE REAR OF THE UNIT. THIS CAUSED ALL THE ICE TO FORM INTO A BIG BLOCK. THE REPLACEMENT UNIT HAS NOT HAD THIS PROBLEM SO FAR.
THANK YOU FOR ALLOWING ME TO EXPLAIN MY SITUATION SO THAT MAYBE OTHERS MAY BENIFIT FROM MY EXPERIENCE.
THANK YOU.

JACK

Noisy fan

  • Customer: Jordan from Maumee OH
  • Difficulty: Easy
  • Time to Complete: 1- 2 hours
  • Tools Required: Nutdriver
  • 84 of 94 people found this instruction helpful
1. Removed the 7 nuts using the nut driver from the freezer back panel inside the freezer.
2. Remove the back panel. The evaporator motor and fan are located above the coils.
3. Unplug the wiring harness.
4. Remove the two gold mounting screws holding the motor and fan in place.
5. Remove the motor and fan including the brackets.
6. Install the new motor and fan onto the mounting bracket.
6a. Attach the green ground to the mounting bracket.
7. Screw the two gold screws back into the freezer.
8. Attach the new wiring harness. Note, the old harness had a mounting hole/space for it to connect to the wiring harness of the freezer. The new motor's harness was not long enough for this, so it is connected freely to the freezer harness.
9. Use the hair dryer to melt any ice that may have formed on the coils and hole where the fan goes.
10. Turn the freezer on to see if the fan turns on.
11. Reinstall the back panel.
All done!

Broken ice maker

  • Customer: Juan from Miami FL
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Socket set
  • 81 of 113 people found this instruction helpful
Unplugged faulty ice maker, removed two screws holding it to the refrigerator and took it out. Reversed the operation with the new ice maker and after a few minutes presto, we have ice.

Side-by-side .. freezer working, fridge not cooling

  • Customer: Tad from Lancaster OH
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 28 of 31 people found this instruction helpful
My freezer was frozen but my refrigerated side was not cooling, the temp was actually around 60-degrees. After inspecting i noticed no air was flowing through the vent from freezer side to fridge side. I removed everything from freezer and took the back wall panel off inside freezer section and immedietely noticed alot of ice on coils etc. After researching i found the defrost timer was not working and thus allowing frost and ice to build up on coils and block air flow. My defrost timer was located on the front bottom left behind kick panel, using a phillips screwdriver i removed 2 screws and then disconnected wire harness to the defrost timer. Then i inserted new defrost timer and connected wire harness and then put the 2 screws back in. My fridge is now working great and the ice build-up is gone and i am getting good air flow .. temps on fridge side are now between 32-34degrees. This was an easy project and saved me alot of money doing myself

Ice maker died!

  • Customer: John from Las Vegas NV
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Socket set
  • 23 of 25 people found this instruction helpful
The repair for this was very simple, although it was a tight squeeze. The model I replaced the ice maker on was a side by side. First I removed the ice bucket so I could have more room to work with. Then I unscrewed 2 screws on the left side wall holding the ice maker in place. These screws had a 1/4" nut top on them so I used my socket driver for this. Then a quick disconnect of the wiring harness. Very Simple. I did the reverse to install the new unit. Total time was around 5 minutes or so. I now have ice again.

The evaporator coil in the freezer would cake up with ice, choking off the cold air flow into the lower refridgerator compartment. A repair man had previously replaced the defrost heater element, but this did not fix the problem.

  • Customer: Erle from Boise ID
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 23 of 26 people found this instruction helpful
First, unplug the refrigerator since you're working with live wires.

Remove the 4 Philips sheet metal screws holding the plastic housing that holds the temperature control to the top of the refrigerator compartment. Pull the housing down then out since there is a tube on the housing where the water flows out the back of the refrigerator during the defrost cycle.

Remove the 2 Philips screws holding the defrost timer on the plastic housing. Pull the connectors off the old timer and attach them in exactly the same positions on the new defrost timer.

Attach the new defrost timer to the plastic housing with the 2 screws.

Reinstall the plastic housing, making sure the water tube is inserted into the back of the refrigerator wall.

Plug the refrigerator back in and you're done.

Ice maker stopped producing ice

  • Customer: Jeremy from Peoria AZ
  • Difficulty: A Bit Difficult
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 23 of 33 people found this instruction helpful
First I removed ice maker and tested the micro switches and motor individually. Then checked the resistance of the heater element, and the thermostat. All components tested okay and worked individually. However when installed in the freezer the motor would not turn. and if you manually turned the gear in front, which should cycle everything,nothing would happen. Finally, I found one part that I had not checked, the thermal cut-off, and upon removing it, one wire fell off the small square piece. This wire was corroded. I replaced the unit in about 10 minuites and ice maker is working perfectly again.

THE EVAPORATOR FAN BURNT UP

  • Customer: ROY from PENSACOLA FL
  • Difficulty: A Bit Difficult
  • Time to Complete: 1- 2 hours
  • Tools Required: Pliers, Screw drivers
  • 21 of 28 people found this instruction helpful
THE FAN MOTOR ALL BUT CAUGHT THE INSIDE OF THE FREEZER ON FIRE . HAD TO REMOVE THEN CLEAN, AND I MEAN CLEAN THE WALLS OF THE FREEZER . THEN HAD TO PRY OUT THE OLD FAN WITHOUT BREAKING ANYTHING . REPLACEMENT OF NEW FAN WAS QUICK AND EASY BECAUSE ALL THE PARTS THAT I NEEDED WERE IN THE BAG

door seals cracking from age on both compartments

  • Customer: Clark from Wenatchee WA
  • Difficulty: Easy
  • Time to Complete: 30 - 60 mins
  • Tools Required: Nutdriver
  • 18 of 22 people found this instruction helpful
Located the many screws which hold the inside surface of the door on. The screws are located between the seal and the inside surface; you have to hold back the seal to find the screws.

The seals are attached to this inner surface by a snug fit, and clamped in place when the screws are tightened again. Its simpler than it sounds.

Finally, it is wise to get a food safe RTV sealant to glue down the corners of the door seals to make they don't scoot around during the life of the seal.

no cooling in fridge or freezer due to bad defrost timer

  • Customer: Todd from pottstown PA
  • Difficulty: Easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Screw drivers
  • 19 of 26 people found this instruction helpful
i removed the 4 screws holding cover. removed two screws holding timer. unplugged timer. plugged in new one. reassembled.

Refrigerator freezing

  • Customer: Miles from Longview TX
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Screw drivers
  • 17 of 23 people found this instruction helpful
Used exploded parts view to locate part. Removed old part and replaced with new defrost timer. Piece of cake.

The old ice maker had stopped working properly. The cycle was inconsistent, and inlet water would run over existing cubes in the tray, before they were dumped into the dispenser box.

  • Customer: Daniel from Baldwin City KS
  • Difficulty: Really easy
  • Time to Complete: Less than 15 mins
  • Tools Required: Nutdriver
  • 14 of 15 people found this instruction helpful
This was really simple, much like changing a light bulb. Two bolts loosened beneath the old unit to allow it to be lifted off and free. The power supply plug was easily disconnected. The new unit was then placed onto the loosened bolts, power supply reconnected and secured with the supplied wire tie. A small angled bracket was removed from the old and reattached to the new as a support toward the from of the unit. The cycle adjuster was backed off a 1/2 turn as per the instructions....and the next morning....new automatic ice. Life is good!

Old icemaker would not cycle to make ice.

  • Customer: David from Cedar City UT
  • Difficulty: Easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver
  • 12 of 12 people found this instruction helpful
I had already removed the ice maker by loosening the two screws with a 1/4" nut driver, in order to compare the design and style to the intended replacement for size and critical measurements. The replacement was almost identical. The wiring harness was 2-3" longer than the original, but after snaping the wire plugs together I simply curved the wire up and to the left to be out of the way. The hanging brackets are slotted and it was easiest to slip the back hanger over the head of the screw and let it slip down, then the front hanger was already to line up even though you can't see the screw with the ice maker in the way. I had to transfer an L-shaped metal bracket to the bottom side, matching the old assembly, and adjusting it to hold the bottom side away from the freezer compartment a little so it would hang level and secure. You have to snug the two screws with a screw driver or 1/4" nut driver by feel, since you can't see them with the icemaker in place. It took about 10 minutes to take out the old and another 10 to put in the new. We now have a full bin of ice, and the old plastic trays have been retired. I should have done this a year ago.

Fridge warming but freezer still frozen

  • Customer: Todd from Thornton CO
  • Difficulty: Really easy
  • Time to Complete: 15 - 30 mins
  • Tools Required: Nutdriver, Screw drivers
  • 12 of 15 people found this instruction helpful
I ordered a defrost timer and defrost thermostat from partselect.com. Parts arrived in 2 days (earlier than expected). Unplugged appliance, removed bottom cover, unscrewed 2 screws holding timer in place, unplugged timer and replaced with new part. Fastened back into place. Next removed back cover of freezer (5 screws using nut driver). Disconnected old thermostat and removed. Wires already had connectors installed. cut off the connectors with some wire left on and reconnected them to the new thermostat with the included blue wire crimps. Tried to use the shrink tube to insulate but couldn't get it snug enough. Just used electrical tape instead. Reinstalled thermostat. Reassembled cover. Plugged in and fridge and freezer are working fine again. Thanks partselect.com.
All Instructions for the 95-1990-57-00