Clicking sound then within a minute clicking again, not cooling.
UNPLUG REFRIGERATOR. Carefully remove relay from the side of the compressor. You shouldn't need a tool to do this, if it is hard you can gently pry the edge with a flat head screw driver just to loosen. Unplug white and red wires from relay, noting that the white wire goes in the hole with a #2 stamped beside it. Shake old relay, if it rattles like a baby rattler then it's most likely the problem. Replace wires into the new relay and plug back into the compressor.
Parts Used:
Compressor Start Relay
  • Melvin from Semmes, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
79 of 93 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door gasket needed to be replaced.
I removed all of the expandable pins that held the gasket and the inner door panel, and removed the old gasket from the inner door panel. The new gasket was then placed around the edges of the inner panel. While holding the gasket and panel in the proper location, the expandable pins were inserted into the mounting holes, finishing the installation.
Parts Used:
GASKET-DOOR
  • Arnold from Quincy, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
19 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Stopped working, cooling.
I used a small screwdriver to disconnect wires from old starter. I connected the overload and starter, two wires. I put the unit back in the keeper, plugged the unit in, turned up the thermostat and it's working beautifully.
Parts Used:
Compressor Start Relay
  • Jennifer from Jonestown, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
15 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer quit. Compressor would not start.
Like another post, the start relay rattled like a baby rattle. Replaced the start relay and freezer works great.
Parts Used:
Compressor Start Relay
  • Steve from Neosho, MO
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
mottor starts than stop.
i looked byhind the freezer , the mottor has the relay connected to it.i took out the relay, and i descovery something was loose inside, i decided to take to check out at sears to see if they have in stock that especific relay. they did not have, they could order, that's when i dicided to go ahead and looking for in the internet, good i found PARTSELECT,they had the part and i was very nice attended,they sent in 2 days i had fix my freezer. thanks PARTSELECT. gilmar couto.
Parts Used:
Compressor Start Relay
  • Gilmar from Miami, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers, Socket set
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
While defrosting freezer tossed the drain plug with ice and water into the sewer system.
Opened mailer and bag and place the drain plug into the drain. fit perfectly. In fact it is better than the one lost since the original needed a screwdriver or tool to remove the plug. This one has a flang or finger turner on it so that it can be removed. Also, does not interfere with items in bottom of freezer.
Parts Used:
Interior Drain Plug
  • paul from LISLE, IL
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
removing the plastic anchorsUsed
Used the flat edge of a screwdriver, which caused me to break off the corners of the plastic shield. Be nice if their was a tool to grab the anchors to pull them out
Parts Used:
GASKET-DOOR
  • Bill from PORTLAND, OR
  • Difficulty Level:
    Difficult
  • Total Repair Time:
    More than 2 hours
  • Tools:
    Pliers, Screw drivers
2 of 2 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
awasome
After reading reviews I was not sure but I ordered part on Wensday in the AM and I had the correct part Thursday evening this company rocks thank you by the way i paid for regular shipping I will order again in a heartbeat
Parts Used:
Compressor Start Relay
  • chris from springfield, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
Was this instruction helpful to you?
Thank you for voting!