No cooling in the freezer or in the refrigerator
Remover rear cover at bottom of refrigerator. The replacement run capacitor was the same as the original one. The replacement Overload Relay Combination was slightly different. It plugged onto the compressor the same, but the connector where the power came in from the wiring harness was different. I had to cut off the original connector from the wiring harness, and then splice in new connectors onto those two wires which I could then attach to the replacement Overload Relay Combination. Fortunately the connectors I needed were fairly common and I had those available. After that it worked. My suspicion is that the Run Capacitor was fine, and it was just the Overload Relay Combination that failed. Replacing the capacitor without replacing the Overload Relay Combination did not fix the problem.
Parts Used:
Run Capacitor Overload Relay Combination
  • Ben from Falls Church, VA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer door handle was cracked
NEW SCREWS NOT INCLUDED with replacement handle! Removed old screws with a phillips screwdriver, cleaned them, reused screws to install new handle.
Parts Used:
Freezer Door Handle
  • EILEEN from TRUMANSBURG, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
lights wouldn't come on/work in refrigerator
Referencing the info/schematics you have on your website, I unscrewed/unattached top-front panel (carefully), from behind the panel you have to detach the wires (2) from the switch, pushed "in" the switch to remove, put in new switch and attach wires to test BEFORE remounting panel. Tada!! Thank you PartSelect! You saved me at least $80...would have been at least $100 to have a repair person come to the house!
Parts Used:
Refrigerator Door Switch
  • Jane from Albuquerque, NM
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fill cup broke.
Very easy to order from parts select. Took seconds to replace.
Parts Used:
Water Fill Cup and Bearing
  • Aliki from Miami, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
6 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Raplaced switch
Repair went well,took about five to ten minutes to disconnect the power from the fridge removed the defective switch installed the new one ,reconnected the power,,,and Let there be light and there was light!
Parts Used:
Refrigerator Door Switch
  • Winston A from Brooklyn, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No ice cubes from ice cube maker
Happen to locate your site by Google. Was impressed and really pleased to find a schematic and directions to find and remove and specs to test the water valve and Defrost thermometer using an electric multimeter. You cannot tell by "looking" at a component if it is still OK.
So I put all the freezer contents into my beach cooler. The repair went as follows.
1. Removed the 6 screws from the back panel and pulled it out of the way.
2. Located the defrost thermostat and pulled it off of the coil.
3. Pulled the two connections off and took it to the bench to test. It showed no readings indicating it was dead.
4. Ordered a new one which came in two days.
5. Had to change the electrical connections using wire nuts.
6. Reversed the process plugged the refrigerator back into the wall. It started and later on I was getting ice cubes.
A great experience. Don't mess with repair guy as they normally are not up to speed on all devices and you are paying for them to learn how to repair your appliance in several trips. Probably using this site. If you can follow instructions, you can do this stuff.
Note. I tested the Water valve using given instructions. More time is used moving things around than the actual repairs. I avoided $150.00 for a new ice maker unit.
Parts Used:
Bimetal Defrost Thermostat
  • Walt from Van Nuys, CA
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver, Socket set
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking ice maker,big chunks ot ice were forming and had to remove them 2-3 times a day
removed old ice maker by taking out a couple of screws in the back of freezer,when new ice maker arrived i saw that it didn't have the same hose apparatus as old one so I easily took apart old one then took apart new one and switched them out-very-- easily done for a 61 yr old lady I might add-- also had to reinstall ice maker arm off old ice maker as new one does not come with one Then installed new ice maker in freezer I am very very pleased,sure saved a lot of money doing it my self
Parts Used:
Replacement Ice Maker
  • Linda from Johnson City, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water overflowing ice maker
Removed the 3 screws that hold the ice maker in place and remove the cover and level wire. Put the cover and wire on new part and install the 3 screws. Had ice within 1 hour. A very easy job for the do it yourselfer. Suspect the heat coil that melts the cubes was not working in the old unit and cubes stayed in the tray.
Parts Used:
Replacement Ice Maker
  • James from Denver, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker just stopped making ice
This was the third icemaker replaced since January 1999. Improvement need to be made in the design of the icemaker so that more than 2-3 years of life is available.
The most difficult part was disconnecting the power plug in the back of the icemaker. You must squeeze the upper and lower tabs together and pull out at the same time to disconnect. Once this is done, take out one nut head screw, lift up on the icemaker and remove from the hanger. Be careful that you don't break the plastic tabs on the hangers. Replace new icemaker in reverse, feed water supply where it must go in the back, resnap onto hangers, replace the nut head screw and snap in the power plug. It took about 2 hours before the icemaker began making ice. It has been working fine ever since. PS. I saved about $200.00 over having a repairman come in and replace the unit.
Parts Used:
Replacement Ice Maker
  • Thomas from Valencia, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Nutdriver
4 of 5 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The refrigerator was warm/ freezer back frozen
Pretty simple really after reading online some other owners' experiences. This is a bottom freezer unit. Remove the ice maker, the tray slides, and the back cover of the freezer box. In my case I had to thaw it out with a hair dryer as the cover was frozen in place. I checked the old 'stat and found it was bad; I temporarily wired the leads together until the new 'stat arrived. It does allow the refrigerator to warm up during a defrost cycle but it beats de-icing it twice.The defrost 'stat is clipped over the refrigerant line in the upper right corner of the box. Resistance was 65k ohms and wouldn't close on low temp (tested by clipping it to an exposed refrigerant line in another upright freezer) but there was no obvious damage. The one lead on the replacement 'stat has the wrong connector so you have to cut off the original lead from the old unit and splice it on the wrong lead on the new one. I used an epoxy sealed heat shrink type butt splice. Reassemble and let it run. One word of warning: be careful tightening any screws as they will strip easily
Parts Used:
Bimetal Defrost Thermostat
  • David from Emmitsburg, MD
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
5 of 8 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
refrigerator was getting warmer.
first thing i thought was the condenser was plugged so pulled out and cleaned with shop vacum backwards so it became a blower not a vacum cleaned it good and put together. wife noticed cracking noise inside freezer. took all freezer food and shelfs out. took 1/4 inch hex nut screws out and found complete condenser solid ice. did some research on internet and found parts select stories. i buy passed thermostate and hooked heating coils direct which then thawed condenser. checked timer by turning of and it worked fine until i got part and installed.
Parts Used:
Bimetal Defrost Thermostat
  • david from bondurant, WY
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig began to trip the GFI circuit in the garage. When plugged into a house interior circuit the lights and fan ran but no cooling in either the freezer or frig.
First of all I want to thank Michael from Carlisle,PA and this site for publishing Michael's info on the wiring specifics on the new 3 connector Start Relay ( WP2262185 ). The original relay only has 2 connectors The 2 orange wires which are combined to one female connector need to be clipped and separated each to its own connector. Refer to Michael's blog as to which wire goes to which connector on the Start Relay. I replaced the Run Capacitor, Start Relay and Overload just to be safe. The Start Relay was the actual culprit.Thank you for an excellent website!
Parts Used:
Run Capacitor
  • riley from CAVE CREEK, AZ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Socket set
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Original handle was loose.
Removed broken handle and replaced with new one by inserting 2 screws. Just took about 2 minutes and is a great improvement!
Parts Used:
Freezer Door Handle
  • Maryln from SANTA ROSA, CA
  • Difficulty Level:
    Very Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
ice maker dripped water into ice bin, freeezing into large block of ice,
turn off water and unplug fridge. remove ice maker bottom mounting screw. just loosen the 2 top mounting screws. unplug wire harness from back of fridge. remove old icemaker from freezer compartment. once removed, salvage square endcover and reinstall on new maker. unfasten wire harness from old maker and reinsatll on new one. reinsert thermal wire in new ice maker holding bracket. remove second wiring bracket and reinstall on new maker to hold remaining wires (not mentioned on "how to-" video). remove old ice maker on/off bale and reinstall on new one. remount new maker to top mounting screws, reinsert harness plug into fridge. replace bottom screw,
Parts Used:
Replacement Ice Maker
  • charles from PHOENIX, AZ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge and Freezer getting too warm.
In Freezer, removed the 3 screws hold up the dial to select the temperature. Once this is lowered you see the Cold Control Thermostat. New one was a bit different, but still fit. I carefully bent the sensor wire to come around to the front of the so it would fit. Slide the plastic tube over the sensor wire. I guessed on the Red and Yellow wires. I don't know if it matters if this is AC. I think I had the Red closest to the front. 2 prongs for the ground, but just need the small one. Put is all back together and it is working great.
Parts Used:
Cold Control Thermostat
  • Ted from NEDERLAND, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver
3 of 3 people found this instruction helpful.