Everything worked perfectly---thanks to the suggestion of your call center agent. She suggested that since the replacement door handles were no longer available, I should consider repainting them--it worked like a charm. Please tell her she was a life saver. We rent that house in Fl and my returning tenants had complained about the discoloring refer handles. Thank you
1. Unplugged refrigerator. 2. Emptied Freezer. 3. Removed Ice Maker. 4. Waited a few hours for ice to melt around back panel & nuts. 5. Removed back panel and the cover over fan and fan motor. 6. Waited many more hours for ice to thaw over fins, wiring, etc. 7. Easily replaced the bi-mental defrost thermostat. 8. Replaced panel, fan cover, ice maker. 9. Plugged in refrigerator and waited a bit.
This worked! Yahoo.
p.s. I am a 65+ year old mechanically minded woman. :-)
freezer gets too cold then gets to regular tempetured
disconect the power removed the screws with the phillips screwdriver removed the front cover and then removed the rest of the screws. removed the three covers and then removed the thermostat. replaced in reverse order.
Freezer wouldn't defrost/low temps in refrigerator
Found the housing for the thermostat; took housing apart pulled out thermostat and took off the hose put the hose on the new thermostat installed new thermostat and replaced housing.
I ordered the 2 new drawers, the crisper pan and the meat pan with handle. I took them from the box, wiped them out and slid them right into the spots where my previous drawers were. End of story. This took less than 5 minutes to install. I used the chat feature to inquire as to what number items that I needed to order these 2 drawers, was given the numbers and order the items on line right then. Easy They arrived in record time, like maybe 2 days. They were well packed and arrived in pristine condition.
Refrig Door Cams wore out and made noises when opening and closing.
Followed Door Removal instructions by removing the Top Screws from the Cabinet. Lifted Door OFF the Metal Hinge. Unscrewed both Lower and Upper Cams from the Hinge and Door. Replaced with new after coating with Vasoline. Lifted Door back in place with help from Wife. Only problem was guiding the Door back onto the Hinge. Works fine. Two year old Frig. This is a design problem, as the cams should last longer than 22 months.
The frig/freezer shut off too often and would not stay cold.
The new thermostat assembly installed quite easily, just a couple of screws, but the thermostat probe however was kind of a pain in the rear. The probe is about 3 feet long and you have to remove a plastic sleeve from the old part and re-install on the new probe, it fits very tight and takes some time to do. Overall it was a very easy fix.
left the shelf/vevetable in place. used pliers or adjustable wrench to remove broken peice. a standard adjustable wrench will remove this peice, it has flat surfaces to grab. make a 1/4 turn going upward. use a flat tip screwdriver to remove old part. discard old pard. insert new part into shelf support hole flush or fully into the hole. While applying a slight amount of force to keep part flush against the wall make a 1/4 bownward part is self locking. I think you only get one chance so take it easy.
Removed the top plastic hinge cover, remove (2) bolts from top hinge. Lifted door up and off of lower hinge, removed both halves of door cam, replaced cam halves and re-installed door. Super easy and effective. Door now opens and closes (stays closed) properly.