Twice I ordered the oven light bulb & each time the light bulb was defected
I had to call for a appointment for repair with GE Appliance because I thought then it . .was something electrical. The technician came out & checked everything out, turned out it was not electrical, The technician went out to his truck got a light bulb from his truck, put it in & it worked. It cost me $121.00 for trip charge from GE appliance for a light bulb that worked, your light bulbs were defective twice. Very disappointed with your products, cost me alot of money for a good light bulb thru GE appliance
Parts Used:
Light Bulb - 40W
  • Barbara from BELLEVUE, WA
  • Difficulty Level:
    Very Difficult
  • Total Repair Time:
    Less than 15 mins
14 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Switchlight was broken on tennant's refridge
as described, I used a thin screwdriver to wedge in and pull down existing, broken switch. I was able to pull it down about a 1/4 inch, but wasn't quit able to disegage it until I gripped it with pliers. I then pulled it out, unplugged the old switch, plugged in the new switch, and carefully tucked the wires back into the fridge and snapped the new switch into place.

10 minutes total.
Parts Used:
Light Switch
  • Mark from Somers Point, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice maker Stripper lost a tooth
First turn off the power, remove the ice tray, remove the two screws holding the ice maker to the side of the freezer, use the screw driver to gently open the electrical clip for the power cord inside the freezer, remove the complete unit from freezer, bend the old stripper from the holding pin- it is flexible- it will bend, replace the new stripper on the holding pin and bend into the slot to hold it firmly, no water will come out from the fill cup into the freezer, plug in the power cord, mount back to side of freezer, you are done.
Parts Used:
Icemaker Stripper
  • Ernest W. from Charlotte, NC
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was cold but refrigerator was hot
After diagnosis though Part Select I determined it must be the defrost heater. I took the panel off on the inside of the back wall of the freezer and used a hair dryer to thaw the ice buildup. I found the bottom element was burned out. I ordered the defrost heater kit and the defrost timer in case that was faulty too. Parts arrived next day. I installed the heater kit and replaced the panel. Then took off the plastic cover inside the refrigerator. One screw near the top of the metal box allows you to remove it to get to the defrost timer.
Parts Used:
Defrost Timer Defrost Heater with Thermostat
  • James from Austin, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
9 of 9 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
broken ice maker
removed 3 screws unplug and remove old unit. install two screws install new ice maker, tighten screws plug in and turn on. had ice in 20 min.
Parts Used:
Ice Maker
  • robert from bensalem, PA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
fridge quit coolingg / freezing
remove lower back cover - disconnect wires to fan motor - place 6" fan to blow on condenser - fridge began cooling & freezing again - ordered part - part arrived - removed fan motor & bracket - cleaned brackets & fan blade - cleaned lint & dust from condenser compartment (took longer to clean than anything else) - replaced fan motor - replaced cover - was hero with wife ... :-)
Parts Used:
Condenser Fan Motor - 115V
  • JEFF from HAMPTON, GA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
10 of 12 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
leaking water / icemaker valve
Simple. UNPLUG THE FRIDGE. Remove set screw holding valve to frame, switch hoses one at a time into new valve, switch wires one set at a time from old to new, re-attach the new valve, turn on water , plug in fridge, check for leaks. 2-minute job.
Parts Used:
Dual Inlet Water Valve
  • Lorry from Bentonville, AR
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Nutdriver
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator & freezer became warm.
Unplugged the refrigerator. I took all the food items out of the freezer, took out the ice bin and shelves. Then I unscrewed the back panel and removed it. The freezer coils were frozen over with ice. Then I used a large fan to thaw the ice and cleaned up the water with towels.
I unscrewed the old defrost heater at the bottom of the coil section, removed it and screwed the new defrost heater part in. I ended up using some dikes to cut the wiring midway up . ( I was going to use the new plastic plug that came with the new part, but it wasn't correct ). I spliced the wires together ( the color scheme was the same - pink to pink, blue to blue, etc), capped them , taped them with electrical tape, and I covered them with a corner from a sandwich bag and taped them a bit more to keep moisture out. Then I tucked the wiring up away from the coil section. I also spliced this little cylindrical part into the existing wiring harness and clipped it onto the copper tubing. ( I suspect this is the defrost timer, but I'm not sure ). After I removed the the old cylindrical little part, I noticed the cap was popped out of it. (it looked like it was damaged a bit ). Once I got all wiring tucked away and back in place, I put the back panel back on, plugged it back in. Voila'. Easy as pie. It's been running fine ( about a week now) ever since. I replaced the thermostat sensor first since that was the cheapest part, but it wasn't the problem. So I moved on to the defrost heater and that ended up being the bad part. I repaired my refrigerator for less than $100.00. Thanks PartSelect. You rock!
Parts Used:
Defrost Heater with Thermostat
  • James from Garland, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Screw drivers, Socket set
10 of 13 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker was leaking all over freezer compartment
Pulled out the fridge, took off the cardboard back. Get a nut driver instead of screwdriver (easier). TURN OFF WATER NOW. UNPLUG FRIDGE NOW. Removed one screw holding valve. Pulled off electrical connectors. Use two small adjustable wrenches to remove water lines. Tag the plastic tubes (I marked RED and BLUE). Grab the new valve and try to stuff it into the same space. Whoops ! Dang plastic housing protecting the electrical from the water is in the way. Have to cut most of it out to make it fit. By the way, DONT follow the instructions about take the bracket off the OLD solenoid. You don't need it. Just throw it away. Connect the wires (remember to use the adapters sent with the new solenoid) Mount the new solenoid (now that the plastic is out of the way) with the one screw (nut driver). Hook up the supply water line (wrenches). Hook up the plastic tubes (aren't you glad you marked them ?). The tubes just push into the new solenoid, no more threads. I just left the plastic nuts on the tubing. TURN ON THE WATER. Check your connections for leaking. Do this before plugging in the fridge. If OK, plug in the fridge. Run some water on the door, look in about an hour to see if cubes are making now. Put cardboard back on fridge. Push fridge back against wall. CONGRATULATE YOURSELF ON A JOB WELL DONE.
Parts Used:
Dual Inlet Water Valve
  • Mary from Langhorne, PA
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
9 of 11 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Will not make ice
Bing , Bang, Boom.
Parts Used:
Ice Maker
  • GEORGE from ELIOT, ME
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
13 of 23 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Ice Maker wouldn't work, water tube freezing up, water leaking onto floor
My problem was that the tube from the water valve to the ice maker was freezing when the valve was malfuntioning and sending more water, causing it to back up and freeze in the reception tube. Then the plastic water tube from the valve to the freezer seperated and water was leaking onto the floor. By reading the repair storyies on the Partselect website I learned that the water valve was not working correctly and needed replacing. I ordered the replacement part on a Wednesday evening and had the part at my house via FEDEX on Saturday morning. It took me about 20 minuttes to complete the entire repair.
I had shut the water off to the valve and unplugged the refrigerator.
First I took the ice storage unit out of the freezer. I then unsrewed the ice making tray from the left side of the freezer. I lowered the unit to the shelve but did not disconnect the wiring. I then pulled the water reception tube that goes from the ice maker to the outside of the refrigerator on the top right rear. There was grozen water contained in the tube. I ran it under the sink and released the frozen water so the tube was clear. I reinserted into the tunnel it sits in and reattached it to the 90 degree plaqstic fitting in the outside of the right rear of the refrigerator.I reattached the plastic water hose from the water valve to the 90 degree fitting. I then reattached the ice maker in the freezer compartment.
Using a nut driver I removered the rear cardboard cover and insulation from the right rear side of the refrigerator. Using a box wrench I unscrewed and disconnected the copper water tube from the valve. I then removed the srew holding the water supply copper tubing to the refrigerator and removed the srew holding the water valve in place.
I removed the old valve from the back of the refrigerator.
I then took note of the electrical connections and transferred them to the new valve. I needed the two adapters(supplied) for the right side electric terminal.
I then transferred the water connection tubes. Take note one is larger than the other. On the old valve they screwed into the water valve with a compression nut. On the new valve you only needed to insert the plastic water tube into the right size hole and push. The comression connection is automatic and does not require the nut. ( I just pushed the nuts back on the tubing and left them). There is a plastic seperation piece on the new valve. I just twisted it loose and removed it. This allowed ease in positioning the valve and water tubes.
I then inserted the new valve into the right rear of the refrigerator and resrewed the unit to the frame using the nut driver.
I then re-attached the water supply copper tubing onto the nipple on the new valve and using a box wrench re-attached same.
I then turned on the water supply to the refrigerator and checked for leaks.
I then replugged the refrigerator into the electical outlet and started the ice maker cycle.
I waited to see that all was working correctly. i then re-attached the insulation and cardboard cover on the rear of the refrigerator and pushed the unit back into the wall space.
Everything is working great now!
Parts Used:
Dual Inlet Water Valve
  • Drew from Spring Lake, NJ
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers, Wrench set
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fan had quit; needed replacement.
The fan was the correct part. It arrived one day after my well trained son-in-law had left for Texas. I had to install the motor myself. He had trained me well; it was not hard. the most difficult was getting the two tabs on the fan housing to fit back into the frame of the refrigerator where they belonged. Thanks. the part & delivery were overpriced, but I needed seed and convenience. Thanks for getting it right the first time.
John Moragues
Parts Used:
Condenser Fan Motor - 115V
  • John from Divide, CO
  • Difficulty Level:
    A Bit Difficult
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Screw drivers
10 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
freezer not frezing properly frost buildup
Removed housing around timer. Unpluged and
replaced timer. Defrosted freezer witk small portable heater. Freezer has worked greater since.
Saved a lot on service call.
Parts Used:
Defrost Timer
  • Bill from Columbiana, AL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Solenoid controlling the valve had stopped operating.
I first tested to make sure the solenoid was receiving power. Every time the arm on the ice maker cycled, the meter would go up to 120v for about 10-15 seconds, and then back to almost 0, so I knew the electical control and timer was working as it should.

The valve was easy to change - took about 20 minutes total (including pulling the fridge out and pushing it back in). I just turned the water off, removed the valve assembly from the fridge, and took all of the lines off of the old one. I then hooked up the supply line to the new valve assembly. The lines to the water and ice had compression fittings on them, but the new vavle has a "push-in" connector. So, I cut the old water and ice lines squarely, just past the fitting, then pushed them in firmly. Plugged the connectors in, re-attached the vavle assembly to the fridge, turned the water back on, and viola - I had ice in about an hour! Gravy! :)
Parts Used:
Dual Inlet Water Valve
  • Eric from Rose Hill, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
8 of 10 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The regrigerator would not defrost properly. After doing some online research, I determined that the Defrost Heater was no longer working.
First, I had to remove the back panel in the freezer. This exposes the cooling coils and the Defrost Heater which is located toward the bottom underneath the cooling coils. There are four screws that have to be removed before the old Defrost Heater can be taken out. There are two wires that go from the Defrost Heater to the power connection. These wires are blue and pink. I had to remove some pieces in the back at the top of the freezer to expose the power connection for the Defrost Heater. These pieces were held in place with phillips screws, so they easily came out to reveal the power connection. The power connection is a simple plug-in type. The Defrost Thermostat is also included with the new Defrost Heater. This is a round piece which is clamped onto the Cooling Coils. I removed the old Defrost Thermostat. It is connected to the same power connection with the Defrost Heater. After I mounted the new Defrost Heater and Defrost Thermostat and connected the power, the refrigerator has worked perfectly.
Parts Used:
Defrost Heater with Thermostat
  • David from Lakeland, FL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Screw drivers
7 of 7 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
All Instructions for the 36358047893