Freezer was getting a build up of frost on the condenser and wasn't cooling.
First I remove the back panel which had 4 screws. Then I removed the ice maker. The icemaker is held in place by the 2 screws that requires backing the screws out just a litter, than lift up and remove the electrical connector. Used a volt ohm meter to check the resisitant in the heater element and the defrost timing switch. Both tested good and that left only the thermostat. Removed and replaced the thermastat swich. I cut the ends of the old switch and crimp the ends of wire with the crimps that came with the swict i purchased from parts select. My refrigerator is working properly and making ice like normal.
tested defrost timer and heater. And then tested defrost timer with ohm test($6 at hard ware store) Closed and would not open replace and tested freezer take 30mins to get switch cold and retest.
A screw driver was used to remove two screws that held the old fan in place the new fan ws installed exactly where the old one came out and presto the job was complete. No major deal.
I didn’t do the repair because the new motor had a female pigtail connector while the original motor has male connection. It came with wire clamps but didn’t want to cut wires to make repair. The pictures online show a male connection. Put the old motor back in and now it works fine.
Discovered the coil was covered with 1/2 inch of ice because defrost cycle had not been working. Replacing the defrost timer and melting ice with hair dryer fixed problem. Hooray!
Seal was old and cracking allowing condesate to rust the door
I should have read everyone else's experiences before attempting. I did view a youtube video and thought I had it set. However, if I had it to do over, the door would have been removed. The door shelf (inner door) taken off and cleaned before attempting to put the gasket on. I did it while the door was still attached and probably lost a good 45mns along with my fingers cramping, knee's flat spotting, and lower back catching fire. TAKE THE DOOR OFF if at all possible, you wont regret it.
There was no work to do. I just slipped the new drawer in. I'm writing because PartSelect was amazing. A rep on the phone helped me identify the part I needed--which was a substitute b/c the actual part isn't made anymore. The next day, the part arrived. I was blown away and want to acknowledge the great service.
My fridge side had warmed up to 70 degrees but the freezer side was still cold. The coils inside had iced up. After thawing with a hair dryer, it froze back after another week. I removed the old defrost thermostat and wired the heater strip directly and turned on the defrost timer. It began melting the ice so that ruled out the heater strip being bad. I couldn't get a reading with my ohm meter on the defrost thermostat so I took a chance and bought the part. Installation was a breeze and it fixed the problem.
Top freezer took off the panel in freezer and melted the ice around coils and found the defrost thermostat and replaced with the new one. Just followed the instructions from your video on line. Freezer works just fine now. Refrigerator is 38 years old.
The bulb has a plastic clear cover. That cover can just be carefully removed using a screwdriver. It's held in by a metal bracket. After you remove the cover. You'll just need to replace the bulb and then re-install the cover and bracket.