defrost heater not working; defrost timer not rotating so coils ice up
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
I ordered the replacement part. Cleaned out the bottom of my refrigerator, popped in the new part, replaced the food and was siting in my recliner in under 15 minutes.
Very easy. Watched a video on your site prior to getting the glass replacement. Removed the crisper drawers. Placed the glass in the front and placed it down. Took just a few minutes. Love your site and will come back again when needed. Thank-you.
After waiting over 2wks for my part to arrive, I purchased the part locally and made the repair the same day as I am still waiting for the part to arrive from you guys. Your customer service really needs improving. I paid for 2 day shipping, what a joke. I will be returning the part as soon as I receive it thanks.
Pull refrigerator from wall and disconnect the water line and unplug the power.
On top of the icemaker, two machine screws hold the icemaker to the side of the refrigerator. You will have to feel around to find the machine screws, but once you do, it is simple to slip the appropriate size socket over the hex heads. I found it helpful to have an extension on the socket wrench. Disconnect the power cable inside the refrigerator (there are little pressure clips on the side that help release the cable) and move it out of the way for the time-being.
Back out both machine screws several turns, but do not remove them completely. The icemaker slips over the screws, so leaving them in the side of the refrigerator makes that process a lot easier. Hand tighten the machine screws once you have positioned the new icemaker in place. One thing to be sure and do is make sure the water line hose coming out of the back of the refrigerator inside is on top of the icemaker. It fits into a slot in the top of the icemaker - failing to do this will result in water pouring into the freezer compartment, not into the icemaker..
Reconnect the power cable to the new icemaker and tuck it up behind the icemaker assembly. Tighten the machine screws completely, but do not over-tighten.
Reconnect the water line on the back of the refrigerator at the wall, and plug in the refrigerator. You should hear the unit fill immediately.
In about an hour you should have ice filling the bin. Enjoy!
REPLACED TIMER-DEFROST 215846602..REPLACED THERMOSTAT-DEFROST KIT 5303918202..REPLACED CONTROL, TEMPERATURE 5304421256..RECHARGED SYSTEM WITH 134A...ALL FANS WORKING...COMPRESSOR RUNS.. FREEZER STILL NOT GETTING COLD ENOUGH...HOLDING AT 20 DEGREES...ANY SUGGESTIONS..THANKS..DAN
I started look inside ,disconnected power, and open all possible compartments to see any burned part. Fortunately I fined a small part look like melted and then i went online and make my research .Then i ordered that part and change it.
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.