removed fan unit from frig and installed new motor and then replaced back in frig. No tools needed. need to unplug unit and take apart and put new motor in the unit and then plug back in.
Remove the freezer drawer by unscrewing the two 12mm screws on both sides of the drawer. Lift the drawer up out of the slots the frame and away. Lay the drawer on a padded surface to protect the drawer cover finish. Pull the old gasket out of the drawer and discard. Position the new gasket around the edge of the drawer. Starting at one corner press the gasket into the slot in the drawer edge. Continue working the gasket until you return to the starting point. Inspect the gasket to ensure it is seated in the slot completely. Return the drawer to the refrigerator, placing the lugs on the drawer into the slots of the frame and insert the screws to their original position and tighten securely. Inspect the drawer for proper level/sealing in the freezer drawer position. Adjust as necessary.
Water outlet tubing leaking in elbow behind water filter
Most difficult and time-consuming part of the job was clearing the refrigerator of food and shelving. Replaced tubing as it had split in the factory bend of the tubing directly behind the water filter. Take your time and don't get in a hurry.
We replaced the damper, but it didn't fix the problem. We then purchased and replaced the thermistor. (We had previously replaced the defrost thermostat). The refrigerator side is now cooling better, but not enough. The damper doesn't seem to be opening. So we have now unplugged the damper and left the opening between the refrigerator propped open and the refrigerator side is now cool enough. (We had previously tried keeping the damper open before we replaced the thermistor and the refrigerator didn't cool off. So the thermistor did fix something, but the damper doesn't seem to have been the problem).
i only ordered 1, so i replaced each 1 then moved to the next. still no light, so it must be someting else. will try to check the wires with a volt meter to see if i have power next. something wierd happen, when i accidently touch the back of the led board, it lit up, small but still light up. hoping that means the led board is goo, must be in the wiring. i saw it had a main led board so will check the power to that.