sometimes it would go into defrost and would not go back to cooling.
I called the repairman who diagnosed the problem as a thermostat then had to order a thermostat took about 2 weeks to get back and install (cost little over $100). did good for about two weeks and same problem reoccured. I decided it was defrost timer and ordered from this site for $19.95 including shipping. I got on ( you tube ) and got instructions(recommend you tube) for DIY install about 15 to 20 minutes. Has been running great for about 3 weeks. ( YOU TUBE IS GREAT FOR A DIY REPAIR ON ABOUT ANYTHING)
defrost heater not working; defrost timer not rotating so coils ice up
Checked for continuity in heater, defrost thermostat and defrost timer. Heater good; not sure about thermostat or timer. Replaced thermostat - no change. Replaced timer - rotating and heater working.
Ice maker is held by 2 screws just above the unit, on the wall of the refrigerator. You can't see the screws, so borrow your wife's makeup mirror. Shine a light into the refrigerator, and using the mirror, locate the two screws, holding the unit in place, on the wall of the refrigerator. Using a nut driver, or socket wrench, with a 1/4 in socket, loosen up the two screws, but don't remove them. Bump the unit upwards, and away from the screws. (BEFORE doing anything!! Shut off the water supply, unplug the refrigerator) When you get the unit freed up, just unplug the old unit, and install the new one. You don't even have to worry about the water lines, and you'll see why, when you get the old unit off. Just reverse the procedure, installing the new unit. Very Simple, 10 to 15 minutes tops.
Had to reach right hand to top of ice maker to locate hex head screws by feel, then place nut driver onto hex head by feel and then unloosen screws with lft hand ,a couple of turns, enough to lift ice maker off screws. Replace new icemaker onto screws and tighten screws. The only problem incountered was the location and availability of having to feel with both hands to fit nut driver onto the screws.(could not see with my eyes because front of ice maker blocked view. )
I removed the plastic shroud on the ceiling of the refigerator, unscrewed and unplugged the old defrost timer, and replaced it with the new one. I reinstalled the shroud with the new timer installed.
Our old gasket was shot to hell, so we figured we'd replace it to see if that would solve the problem. We followed the instructions of another customer. We realized it was better if we removed the entire door in order to attach the gasket. That took a little doing, but it was totally the way to go. Miracle of Miracles, the leaking has stopped, the food is super cold, and I couldn't be happier.
Real simple repair..just backed off the two 1/4" hex bolts holding the ice maker to the wall of the fridge,(a little tricky since you can't see them),unclipped the electrical doo hickey. I re-clipped the electrical do hickey of the new ice maker, hung the ice maker on the bolts and then re-tightened them. However,still no ice,my problem was the water valve on the back of the fridge behind the cardboard. Although it was still giving H2O thru the door it was not allowing water to flow to the ice maker. I reccommend pouring some water into the ice tray of the ice maker. If it makes ice and dumps it in to the holder, your ice maker is OK. If it turns out to be your water valve, that fix is easy as well. I HIGHLY reccommend watching the "fix it" video associated with that part. That repair also took less than 15 minutes. Good Luck! KC Bridgewater,NJ
The defrost timer is faily easy to replace, first unplug the unit, then remove the toe gaurd, then lay on the floor with your light and phillips screwdriver, locate the 2 screws at the lower left side, remove them and the timer and it's shield will drop down. unplug the old timer, plug the new one in and re-install everything. The temp sensor is located in the back of the freezer compartment. Again make sure the unit is unplugged, remove freezer shelves and lower basket, then with a 1/4" nut driver, remove the screws holding the rear panel on, remove the panel and locate the sensor on the upper evaporator tube, unclip it and disconnect the 2 wires, reverse procedure and plug it back in. Not to get on a soap box, but this is the 3rd time i have had the same problem with this unit, plus several other problems.