My fridge temp was warm. Freezer temp was ok, but fluctuated some.
I checked the dampener, it worked. The compressor and fan worked. I knew because my freezer was still hovering around 10 degrees. Coils were clean. Thermistor was the only thing it could be. Took all my shelves out. Removed four screws. Took the back panel off. The thermistor sits tucked in on the side. I piped it out, in clipped it. Used my multimeter to test the numbers. Numbers were off just a bit. Ordered the part. Crossed my fingers.,took less then 5 minutes to put the part in. Plugged in the fridge. It was sitting at 33 degrees in about an hour and a half. I can’t believe I fixed it. I knew NOTHING about refrigerators. For how big my fridge is, it would have cost 3,000 and up to get a new one with the same cu ft size. Instead, it cost me $44. That includes shipping. Thank you Parts Select!! Made it so easy to pick the correct part for my model fridge!
Parts Used:
Temperature Sensor
  • Cindy from AMARILLO, TX
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
25 of 39 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Light Socket short
- Unsnapped old light socket from top of Frig
- Disconnected elect wires
- Reconnected elect wires to new light socket
- Snapped new socket in place
- Done in less than 2 min.
Parts Used:
Light Socket
  • Rebecca from Gautier, MS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
22 of 31 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Water and Ice dispenser quit working.
Turned off power at C/B panel. Took cover off dispenser, removed 3 screws, board held in by 4 screws. Removed all 4, replaced board after removing connecter. Put back together. Turned power on. Worked perfectly. 15 minutes max, part was $81, recieved 3 days after ordered.
Parts Used:
Water Dispenser Control Board
  • James from Lakeland, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
22 of 32 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
No power to Ice and water dispenser
First removed the drip tray with a firm tug, Then removed the 2 screws to remove the trim, had to remove the board to get get to the connector. (there is a clip that holds the wire tight) connected the new ribbon cable and secured it with the clip, screwed the board back in and pushed in the other end of the cable. and screwed the trim back and the drip tray. surprisingly Very easy to do.
Parts Used:
Ribbon Cable Harness
  • Carmelo from Howell, NJ
  • Difficulty Level:
    Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Screw drivers
23 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer is working but not the refrigerator.
Removed the cover inside the freezer. Found out that the motor/fan was not working. Ordered through PartSelect. Got the parts in 3 days. Installed it for less than 30 minutes. Very easy. It saved me hundreds of dollars. We considered buying a new fridge but not anymore. , it only cost me $70 including shipment charges. (Make sure you unplug the appliance first before opening the cover. Remember safety first.)
Parts Used:
Evaporator Fan Motor Kit - 120V 60Hz
  • Neptali from Groton, MA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Wrench set
17 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Fridge side too cold
Most of the time was spent removing frozen food and removing the plastic clip holding one of the shelves in place. Removal of bottom panel took less than a minute. Thermostat easy to find, clipped wires a the unit and removed unit. Used included wire jackets, but not white shrink wrap. This did NOT fix the problem. This was the attempt at a 'cheap' fix. My refrigerator required the 'control box' to be replaced.
Parts Used:
Defrost Thermostat Kit
  • Brian from Eden Prairie, MN
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Socket set
19 of 25 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
2 broken shelving supports
The shelving brackets are install much like a blind rivet. I simply used a punch and gently pushed in the plastic center pin / mandrel. I then used a butter knife as a wedge to pull out the shelving supports enough to grab them with a pair of pliers. Simple to do!
Parts Used:
Crisper Cover Support - Front Crisper Support - Rear
  • Victor from Wilton, CA
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    Less than 15 mins
  • Tools:
    Pliers
16 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrigerator was trying to cycle compressor on, but each time the compressor started, it would stop due to the thermo breaker would open. The fans continued to run, so I figured it was starter relay.
Moved the refrig. out, removed the four screws that held the lower access panel in place. Disconnected the power cord. Removed the retainer clip wire and pulled the relays from the compressor socket. Separated the relays and installed the secondary relay on the new starter relay. Reinstalled the starter relay assembly into the compressor socket. Plugged the power cord in and listened for the compressor to cycle on. It cycled on and continued to run. Turned the power off and reinstalled the retainer clip wire. Reinstalled the access panel and plugged the power back in and left the refrig. run overnight. Checked temperature and also started the ice maker. Everything was normal by morning.
Parts Used:
CONTROLLR
  • Harry from Rockwall, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Freezer was cold but the fridge was warm. Back panel of fridge was building up frost
First of all Don't panic! you can do it and you can save a lot of $$$ if you do it yourself. A friend advice me to look it up online resources and came accross part select on YouTube .

The process:
Defrost the fridge. Take down the panels on the fridge to have room to unscrew the back panels. Once you've taken the back panel out. You will see the thermostat right away. Replace it and voila you're done.
Parts Used:
Defrost Thermostat Kit
  • Albert from Buffalo Grove, IL
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Pliers, Wrench (Adjustable)
22 of 37 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
drip from door water dispenser
The 4 lines attached to water valve have compression fittings.New valve has pex fittings.I cut each line just behind the ferrel and inserted each line into the proper fitting and reattached the 3 electrical plugs.Turned water back on.I immediately got water from thr door without dripping.For whatever reason it was not making ice for the first 3 days,I pulled the plug on the icemaker solenoid and reattached.It is working now.
Parts Used:
Refrigerator Water Inlet Valve
  • Paul from Anderson, IN
  • Difficulty Level:
    Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Pliers
16 of 19 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
evaporator coil would freeze up solid. no air flow through coil; no cooling.
-unplug power cord.(safety first!
-Removed evaporator cover in freezer. found defrost thermostat defective.
-use hair dryer to manually defrost coil from ice build-up.
-unclip thermostat from coil.
-cut wires close to the defrost thermostat; remove defective thermostat.
-clip on new defrost thermostat.
-connect wires using included butt connectors including shrink tubing (also included)
-replace coil cover.
-plug power cord back in.
Parts Used:
Defrost Thermostat Kit
  • KEVIN from BRONX, NY
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver
19 of 29 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Refrig door would not close automatically
Replaced the plastic/nylon piece on the door. First, I remove the door hinge cover by unscrewing the one bolt. Second, unbolted the two bolts that hold the door in place. Third, lifted the door off the bottom hinge. Four, remove the bottom plate that is held in place by 3 screws. Five, using pliers move the old plastic piece from the bottom of the door. Six, press into place the replacement part. Seven, re-install the bottom plate. Eight, rehang the door on the bottom hinge. Nine, restall the top hinge and rebolt the two bolts that hold the hinge in place. Ten, reinstall the top cover. Finished.
Parts Used:
Hinge Bearing
  • Michael from Lithia, FL
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Pliers, Screw drivers, Wrench set
14 of 14 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
It Was Fast And Easy, No To Mention Affordable.
Removed the two screws that hold the element in place. Then I pulled the element out about 3 inches and disconnected the wires. Everything matched up perfectly.
Parts Used:
Refrigerator Water Inlet Valve
  • Jim from Herington, KS
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    15 - 30 mins
  • Tools:
    Nutdriver, Screw drivers
15 of 18 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Door would not shut properly
Removed the door and installed ne bushing on bottom of hinge
Parts Used:
Door Closing Cam Hinge Bearing
  • Matthew from Parker, CO
  • Difficulty Level:
    Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Screw drivers, Wrench set
14 of 15 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Power outage for two days took out control unit
take out screws front control panel ,then screws on left panel holding control unit. had to clean up plastic she got a little toasty. unhooked control unit replaced with new and reassembled. The real story is in your excellent web site easy to find exactly what I need and with prompt shipping, I was back in service quicker than having someone come out and repair.

Great Job
Jeff Baker
Parts Used:
Adaptive Defrost Control Board
  • Jeffery from Nunica, MI
  • Difficulty Level:
    Really Easy
  • Total Repair Time:
    30 - 60 mins
  • Tools:
    Nutdriver, Screw drivers
18 of 27 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!