Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Door retainer bar end broke
The plastic ends are held to the retainer bar by small metal tabs in the retainer bar. Pry up the tabs to remove the broken part. Insert the new part and crimp the tabs back down with a pliers. Couldn't be easier.
First I removed the clamp, pulled out the part, and diconnected the two wires on the side and a small screw. Reconnected the new part with the small screw, connected the wires and plugged the part back to the side of the motor. Whaa La, Done.
I ordered two of the long refrigerator shelf door bars and cut one of them to fit the freezer shelf door because that ready-made door bar was very expensive. The fit after cutting and notching to receive the end caps went very well.
A little difficult getting out due to restricted space, I took off the fan blade, that gave extra working room. Then it went well going back together,and it all worked as advertised. Thanks. p
Door sagging, creating a gap to let in condensation
You tube is my best friend for DIY repair. I supported the door with wood blocks, removed the bottom bracket and was able to slide the refrigerator door down and out without removing the freezer door. Replaced both hinge bearings and door stop and washer on bottom hinge and slid the door back into place. Door is very light when empty. Fast and easy, door opens and closes smoothly and no problem with condensation anymore.
Needed to replace door shelf retainer for freezer as existing end caps had broken
First removed existing damaged shelf retainer bar and end caps from freezer door. Next cut down new oversized retainer bar to size with hack saw. Then slightly opened up doubled over metal at each end of retainer bar with pliers and screw driver in order to create the small "nicks" that are needed to house the "bumps" that secure the retainer bar to end caps. Used tin snips for this. Next inserted new end caps and used pliers to crimp secure. Clipped in new assembly in freezer door.
The refrigerator that came with the purchase of my house had a missing retainer bar in bottom shelf of fridge and a duct-taped retainer bar in freezer. When parts came, all I had to do after removing the duct-tape, was slide up the broken end cap to pop it off then, snap the retainer bars into the end caps and slide them down into place. No tools necessary. Should have done this two years ago when I bought the house!
The repair was not difficult because you just remove the old part and plug it in and connect two wires. But I wish there was a way to test if the compressor is working before I purchased the parts. The compressor would not start so I was not able to repair the refrigerator.
I stuck a small screw driver under the old switch & it came out really easy. I just unplugged the 2 electrical connectors, and removed the old switch. Installing the new one was just as easy. I am a woman!
I also want to say how FAST PartSelect gets their items to you. It came in ONE day!
Your repair stories are very helpful, I/we would have never known how easy this switch was to replace! Thank you!
Switch that shuts out light when the door closed broke
Removed the screws on the piece holding the switch which is at the front of the ceiling of the refrigerator box. Removed the old switch and replaced it. Very simple repair.