This was a simple job. Raised the flap in the back that houses the compressor, removed the wire that holds the relay, pulled out the old relay and pushed the new one on. Replaced wire holder and that was it. Plugged it frig and freezer is at zero and lower compartment at 35. As easy as brushing your teeth!
I located the part that was the culprit as it had buzzed very much before quitting. This is an easy removal as the part is in a two prong jack and just needs to be carefully removed with the new part inserted back in the jack provided. The refrigerator works fine now, but the run capacitor will still buzz on start up of the compressor. I do hope this is normal in this model? anyway it runs fine mow. Thank you.
Watched your video, used a stiff putty knife to pry the gasket loose.Cleaned the surrounding area and pushed the new gasket in. I used a plastic body moulding tool to make sure the gasket was sealed. Very easy repair!
Food compartment not cooling, freezer working well.
Fantastic! Sent in a brief description of problem and model number. Reply and description of other customers experiences guided us to the exact problem. We ordered the part on Friday and it was here on Tuesday. I prepared the freezer compartment for the removal of the old motor and on Sunday husband installed new Evaporator Fan Motor.
It works and is cooling like it did when it was new.
This has been a great experience as all repairmen wanted at least 60.00 to just come out and determine what the problem was. I can only imagine what the final bill would have been.
The site offers a video for this part which worked perfectly. In addition to replacing the part, since the cardboard panel was off, we also cleaned all the dust off of the coils which someone recommended to do annually.
Simple switch repair: Unplug fridge, pull down to remove switch assembly, slip contacts off. Reverse with replacement switch. HOWEVER, check first to see if the bulb filament might be broken, as this could cause the same symptom. OR in my case, the light socket connection was the culprit. Check that too before ordering a replacement switch.
This was a really simple repair. The hardest part was getting the broken piece of the plastic end cap out of the metal retainer bar. I had to use a small screwdriver to gently pry it out of the two notches in the retainer bar. Then I just slipped on the new part, and snapped the whole retainer bar into the fridge door and that was it.
If the end cap doesn't lock into place when you slide it into the metal retainer bar, you may need to bend the bar (gently) to get the notches around the plastic clips. You don't need a lot of force to do this since all you want is to lock the end cap in place.
Lightning struct the house and fried the evap thermostat
Noticed the evap fan wasn't working, so trying to disconnect the wire broke the connection so had to order a new motor. Installed the motor but it still didn't work. Had a technician look at it and he said it was the control board. Ordered and installed control board and still didn't work. The only element left is the evap thermostat. Jumped the thermostat and it worked so ordered and installed a thermostat. It works now
Evaporator fan motor quit and would not circulate cold air from coils.
Remove shelves and rear panels to get to motor. Motor is held in place on shroud by simple strap. Remove fan blade, then un hook strap, remove and save rubber spacers on old motor to reuse to remount new motor. New motor Mew motor has wiring harness that is universal. Cut out the three wires that go to the new motor leaving long as possible, cut wires from old motor as long as possible, strip ends of all wires 1/2 inch, connect wires by color,slip into provided wire connectors and crimp. Pull on wires to insure connection. Tie wires together so they don't touch the coils. Plug in and check operation. If all is working unplug and replace all covers and shelves. Plug back in and it will take few hours to reach operating temperature. Video of side by side repair shows easy removal of panels and motor.
The plastic ends are held to the retainer bar by small metal tabs in the retainer bar. Pry up the tabs to remove the broken part. Insert the new part and crimp the tabs back down with a pliers. Couldn't be easier.
Door sagging, creating a gap to let in condensation
You tube is my best friend for DIY repair. I supported the door with wood blocks, removed the bottom bracket and was able to slide the refrigerator door down and out without removing the freezer door. Replaced both hinge bearings and door stop and washer on bottom hinge and slid the door back into place. Door is very light when empty. Fast and easy, door opens and closes smoothly and no problem with condensation anymore.