Center stack (auger) did not turn with agitator
I was skeptical that this would take less than 15 minutes, but it actually took closer to 5 minutes! (1) Remove the fabric softener cup from the top of the auger by pulling up on the collar as indicated. (2) Pry the cap off the auger with a small screwdriver. (3) Use a long 1/2 inch socket extender (with no socket on it) to unscrew the plastic retainer for the mechanism at the top of the auger. Remove the mechanism. (4) In the mechanism, there's a thin collar holding in the agitator directional cogs. Pry that collar up to remove it. This was the trickiest part. I was afraid of breaking that collar but it survived. (5) Replace the cogs. (6) Reverse the previous steps.
Parts Used:
-
Ronald from West Chester, PA
-
Difficulty Level:Really Easy
-
Total Repair Time:Less than 15 mins
-
Tools:Screw drivers, Socket set