Unplugged refrigerator, Removed lower back panel, Removed fan from fan bracket, Installed new fan to fan bracket, Installed new wire assembly to fan, Replaced back panel. Plugged refrigerator back in and it works great. Only tool needed was 1/4" socket.
I simply removed the old switch using 2 small screwdrivers and the old switch case popped out. I then upluged the wires from the old switch and reversed the process. Didn't take longer than 5 minutes begining to end! Thank you for the great service! Duncan quaid
Followed the video on parts page. I was worried I would brake the cover but learned from the video the right way to remove the front plate. I found the video very informing. Thank you for saving me a service call and the part cost was minimal compared to a new refrigerator .
Refrigerator would not cool down. Evaporator fan inop.
Unplug, then remove shelving and rear panel. Remove fan motor, swap wired and install new motor. Reinstall in reverse order. Plug back in and verify the fan is running. Easy and nothing special. Only thing I would caution is they use a foam runner to the refrigerator that may be iced up. Carefully clean the ice out before reinstalling everything. A follow up note. If the fan has not been running, Ice will build up in the drain tube. When you start up the refrigerator, you will see water dripping into the lower shelf. This is easy to fix. Unplug refrigerator and disassemble to where you can see the coils. There will be ice on the bottom covering the drain line hole. You will need to carefully chip away the ice, then use a hair dryer to melt the ice. Carefully use a pointed tool to push in the drain tube until the water drains. Go slow and be patient. Heat is your friend when doing this.
Intermittent performance, then Frig. quit completely.
Hesitated for a month. Bought part most likely to have failed. Almost instant delivery (as always). Put in part in 15 minutes (including taking cover off). Turn frig. on. First nothing, then in a few minutes it cranks up -- oh, how beautiful. It's been working perfectly ever since. Thanks for being great help!
I pulled the refrigerator out from the wali slowly so not to damage the water line to the ice maker. Then with a nut driver I removed all the screws holding the back plate on. Being careful not to kink the water line, I used the adjustable wrench to losen the water line feed nut and the nut that goes to the line to the icemaker. Then I removed the screws holding the valve in place finished unhooking the water lines with my fingers. I then got the new valve and finger tightend the main water supply nut to the inlet side, then I pushed the plastic supply tube going to the icemaker into the valve. The new valve does not use a nut to attach the tubing it is a presure fit very easy.
Freezer would periodically allow things to partially thaw out
First, I removed the two thermostat knobs, then the snap-on plastic cover. Then, I removed the 4 screws holding the housing for the timer, thermostats, etc., and dropped it down enough to remove the timer and the wiring harness going into it. Installing the new one was the same process, in reverse. Quite simple!
freezer constantly covered with ice not defrosting
I opened rear wall inside freezer (two screws) cut the wires on old thermostat and removed it. Then I attatched the new thermostat to the existing wires using wire nuts and electrical tape and slid it onto the copper tubing. Re-installed the rear wall. Freezer works like a charm and the refridgerator is also colder. Job completed in twenty minutes and Tim Allen has nothing on me. Mike Milne
Leakiong water from the freezer compartment into the lower refrigeration compartment
After unplugging the appliance, I unscrewed the screws in the bottom and the back of the freezer compartment and un-clipped the connector for the ice machine, which i do not have installed. I clipped the pink and brown wires and replace the switch with the new switch. unfortunately, the appliance is still dripping water from the freezer compartment. It worked for a couple of days then stopped working. Still looking for a true FIX.
I ordered the drawer which arrived 3 days later and I just took out the old one removed the white handle cover placed it on the new drawer and put it back in quick, easy done.
Took part out of box..Took old part off and installed new part .. Plugged in Refrigerator.. so far is operating great performance..Thank you for shipping in record time..you made this sitution painless ..will definitely recommend to all my friends to shop with PartSelect first .. Thank you so much.. It was one of the hottest day of this summer and for my Refigerator to go was a horrible thought.. with your shipping and reciveing this part was a perfect ending to a bad day... Gina Hayden
Freezer was dripping water into refrigerator below
Removed the old timer from the housing. The replacement came with good instructions. I followed the instructions corresponding to the color wires in my unit. The first time it was installed, the fridge did not come on and the temperature rose after a couple hours. Looked at the part and realized the defrost cycle must have kicked in. Needed to slightly turn the gray slotted part to initiate the timer so it would stop the defrost and start the fridge. That did it! It must have advanced the timer so it could accumulate run time. Whole repair saved us $3000 in a new fridge.