The Ice maker would not work.
We rolled the refrigerator out away from the wall and it was obvious where the break was located. We took out the old water spout for the ice maker and replaced the tube and the tubing from the solenoid. We turned it on and soon we had water dripping everywhere. We unloaded and defrosted the freezer which got all of the remaining ice that was stuck in there. We put everything back together. I read in some instructions in the manual that it might take 24 hours for the ice maker to reprogram itself and start producing ice. I was only about 12 hours and we had ice again and everything worked well. You really do not have to disconnect the water from the main line, the solinoid controls that part of operation and turns the water off until the ice trays are free and clear.
I called the local Amana repair man, wanted $150 for a new ice maker because they could not get the part I needed. Found Partsselect.com and the part cost $17 with shipping. They saved me over $100. The repair was very easy too, just removed a couple of screws.
Removed 2 control panel knobs and face plate that is snaped in place using a knife to prey it causing to snape lose. Removed 4 cover screws that gave me acess to Defrost Timer. Remove two fastining screws on timer unit. Remove electrical color coded 4 prong connector plug. Have to make sure black jumper wire on the new timer kit is connected to the correct one of the 4 prongs as to instruction sheet for my model refrigerator. Reassemble in reverse order. Bingo! Fixed.
I took the cover off the control settings and found the timer. Removed two screws and replaced the defective one with the new one. Had to pay attention to directions since the timer is used in different ways and to make sure the loose wire was installed correctly (not the same way as the original ground was connected).
remove shelves in freezer compartment incl.holders(slide up to remove) Remove lamp/shield Remove panel (six phillips screws) disconnect motor pull off fan blade squeeze bracket holding motor to remove remove motor. Re-assemble (in reverse)
Fan and Light working but would not cool down inside
This problem first accrued when the unit was under warranty and the repair person told me this would happen again. This technician told me how to troubleshoot the problem and sure enough the Compressor Start Relay was bad again. For starters I moved the refrigerator out from the wall and cabinets. I unplugged the wall cord from the receptacle. I removed the screws, with a ¼ inch spin-tight that held the backing in front of the compressor compartment. I disconnected the two wires then pulled the Start-Dev PS991485 out and it rattled, a good sign the relay was bad. I looked up the Part on the Web Site and ordered the replacement relay, I thought. When the package arrived I found all the parts for the entire Starting and over Temp Protection circuits along with a new plastic cover box. This was a very good experience and I saved maybe $250.00 in repair costs by doing it my self, along with the replacement instruction that came with the parts.
Water leaking from under refrigerator. Initially believed leak was from filter assembly. Removed filter and shut off water supply but leak appeared at different intervals again. Large puddle of water coming out from under refrigerator. Removed back lower panel and checked for leak, but didn't find any. My wife was also checking for leak and found a crack in drip tray. Only way we could get the drip tray out was to first remove front lower panel, disconnect and remove wiring harness in front of drip tray, unbolt water filter assembly, and unbolt water solenoid unit at rear of refrigerator. Their water lines connect to filter assembly. My wife controlled the water solenoid unit to give me play as I pulled the filter assembly out as much as I could from the front. I could now wiggle the cracked drip tray out from under the filter unit. Replaced drip tray and reinstalled wiring harness, water filter unit w/new filter, and re-bolted water solenoid unit at back of refrigerator. Replaced back lower panel after turning water back on and checking for leaks. Replaced front lower panel.
The reason still had leak after initially turning off water supply was because the drip tray is used to catch the water when refrigerator goes into the defrost cycle. Since the original drip tray had cracked, water only appeared on floor after defrost cycle.
I pulled the refer from the wall, disconnected the power and removed the cardboard cover at the base. Using a vacuum and compressed air, I cleaned it thoroughly. I used a screwdriver to lift the locking tab on the 3-wire connector and removed it. The best way to get the three bolts off was with a 1/4" drive ratchet and go to the std nutdriver handle when they were loose. The fan came out carefully with the blade. I removed the blade nut with flat nosed pliers, cleaned it and placed it on the new motor. I replaced the motor and installed the screws. On a do-over I would install onew screw in each hole at least halfway to get the threads started/ threaded. After that the connector slipped in and I spun the blade to check for interference. The blades can be slightly bent, but use of nut tension can also slightly adjust fan alignment as it's tight to the housing. That's it
Removed catch tray and then removed two screws that are underneath. I left the control panel hanging from its wires, then removed the two screws from the control bracket. A word of caution before next step: You need to remove the two micro switches on the left and right. While trying to remove one, it split apart and the pieces fell out. I was able to put it back together and it worked fine. So be careful with the micro switches. Continue tranferring wires and switches to the new bracket and reassemble in the opposite order. An easy repair.
First I unplugged appliance then I remove two screws from the thermostat/light cover. I then remove two defrost timer mounting screws and all electrical connectors. Then utilizing instructions recieved with new defrost timer I ascertained which wires should go where. When I was sure I had the wires ready I connected them to the others in the appliance and plugged the appliance in to ensure that the noise was no longer heard and made sure timer was working. Everything seemed fine so I unplugged appliance and secured two defrost timer mounting screws and thermostat/light cover mounting screws and that was that.
the ice dispenser, micro switch control bracket broke and the ice was not dispensing
Removed the screws that held the control breaket. Then I removed (2) micro switches, and for a cable tie, I slide the old control bracket out and installed the new one purchased from your store. 5 minutes worth of work. THAT IT!!! It was very, very, simple the repair
The fan wouldn't run as needed. The top of the refrigerator was really hot.
My husband took the old motor out by taking the screws out. Then, he unplugged the fan. We searched your site for the part. With the pictures on the site, we were able to match the motor exactly. The delivery was really fast. When we received the part, he installed the fan and plugged in the power connector. We have replaced refrigerator fans before but anyone can do this with no experience. Just follow the instructions and you're all set.
'Frig door made a popping sound when opening and closing.
Removed upper hinge cover and hinge, lifted door from lower hinge socket, removed lower cam from 'frig hinge, and replaced with new. I had a helper hold the 'frig door while I removed old upper cam, and replaced with new. Piece of cake and works like new! This must be a design problem..