Leaking Water

ApplianceGeneral Electric Refrigerator

ModelTPX24BPDA

Level of DifficultyEasy

Time to do repair15 - 30 mins

Age of Appliance5 - 10 years

Tools Screw drivers
Wrench(Adjustable)

Paul From Danvers, MA

Nov 30, 2010

8 out of 10 people found this instruction helpful

Unplugged frig. Turned off water supply to pump. Removed black cardboard covering on back of frig with nut driver (6 screws).

Took digital photo of assembly to confirm reassembly position.

Removed copper waterline to pump with adjustable wrench. Removed 1 screw holding pump assembly to refrigerator. Pulled assembly out of the frig. Unscrewed two small black screws on a second bracket. Pulled old pump further out of frig. Unplugged two connectors. Removed plastic waterline from pump by turning hose counter-clockwise and gently pulling.

Inserted plastic water line into new pump by turning line in clockwise and it pushing into orange plastic stop. Reconnected two electrical connectors. Reconnected bracket to pump with two small black screws. Gently pushed assembly back into the frig and reconnected pump assembly to the frig with 1 screw. Reconnected copper water line to pump first wrapping threads on pump with Teflon plumbers tape.

Turned on water to check for leaks. Installed cardboard back on frig with 6 screws. Plugged in frig.

NOTE. My new pump assembly had the electrical connectors reversed. Take care to pair up the correct colored connectors.

Help other customers find the most helpful instructions.

Were these instructions helpful?

Diagrams and Parts List for this repair

Part PhotoPart DescriptionPriceAvailability

Primary Water Inlet Valve

Part Number: PS304365

$45.34
In Stock