Frigidaire/Frigidaire_Thumb/7D9C9AE5198802C9713D9F0ABE13BDBB89FEF57B.gif
See part 8 in the diagram
( Grid squares measure 1x1 inch )

Get in touch, we're here to help!

Open until 12am EST

customerservice@partselect.com

PC BOARD

Rated by 1 customers 

Easy 

1- 2 hours 

Ratings submitted by customers like you who bought this part.

$ 124.66   In Stock

Get this part fast! Average delivery time for in-stock parts via standard shipping: 1.8 days.

PartSelect Number PS9864875
Manufacturer Part Number 5304496261
Manufactured by Frigidaire
Troubleshooting
This part works with the following products:
Air Conditioner.
This part works with the following products:
Frigidaire, Crosley.
Part# 5304496261 replaces these:
AP5948755
Questions and Answers

We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.

6 questions answered by our experts.
Sort by:
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Jerry
July 30, 2018
Air conditioner compressor does not shut off when fan for cooling does.
For model number FFRH1822R20
Hi Jerry, Thank you for your question. If your air conditioner will not shut off and keeps blowing cold air, it may be due to an issue with the control board, also known as the PCB assembly. A sensor monitors the air temperature in the room and signals the control board to turn on the compressor and begin cooling. The board relays may be faulty if the compressor keeps running well after the ideal temperature has been reached. The board processor circuitry may also be the source of the issue. Some air conditioner units have a separate relay board, in which case you can use a multi-meter to test each relay output for continuity and determine if one is at fault. You air conditioner may not shut off or stop blowing air because of an issue with the temperature control, also known as a thermostat. For rotary dial thermostats, there will be a set of internal electrical contracts which power the compressor circuit, to signal it to blow cold air. This set-up utilizes a sensor bulb, located near the evaporator coils, to monitor room air temperature. If the temperature control contacts become stuck in the closed position, the compressor will keep running after the ideal temperature has been reached, and keeps blowing cold air. Check the sensor bulb to make sure it is properly attached to the coils before replacing the temperature control. If your window air conditioner will not shut off, it may be due to a problem with the thermistor or temperature sensor. The thermistor is located near the evaporator and monitors the air temperature in the room. It signals the control board to turn the compressor on or off as required. The temperature sensor or thermistor may not be working if the air conditioner is not shutting off, because it isn’t getting the message that ideal temperature has been reached. To test the sensor, check your manual to find the exact specifications for the thermistor and measure with a multi-meter. Check the other components such as the control board for any visual signs of a loose connection. I hope this helps. Thank you and have a great day!

6 people found this helpful.

Was this helpful?
Thank you for voting!
Steve
November 7, 2019
When unit is turned on a/c mode and turned off it doesn’t turn off but when in the heat mode fan turns off but sounds like compressor keeps running. Unit will not turn off unless power supply is unplugged.
For model number FFRH08L2R10
Hi Steve, thank you for your question. There are a couple of parts that you could check for that issue. You should take a look at your thermistor, sensor, and your fan switch as well. I hope that helps. Good luck with your repair.

2 people found this helpful.

Was this helpful?
Thank you for voting!
Alex
August 29, 2019
Hi my unit don't change the temperature stays on same won't go up or down and the compressor stay on when i turned off the unit about 10 min. Thanks
For model number FFRH08L2R11
Hello Alex, thank you for writing. This is most likely due to a faulty Evaporator Thermistor Sensor, part number PS2359468 for your model. Good luck with your repair!

1 person found this helpful.

Was this helpful?
Thank you for voting!
Randall
September 19, 2019
Window unit keeps cutting on and of bagels seems like when u try to change temp or push any button on display starts cutting on and off
For model number Ffrh2522r2
Hi Randall, we cannot be certain what is causing this, definitely the control board could be causing the issue. Thank you for your question and good luck with your repair!

Was this helpful?
Thank you for voting!
Spencer
October 31, 2022
Compressor does not shut off unless you hit the reset button. I have already purchased and installed the front control panel from your company and installed but the issue remains. On this unit is the a relay somewhere that is stuck closed allowing the compressor to continuously run?
For model number ffrh1822r2
Hello Spencer, thank you for contacting us. Please make sure that the condenser coils are clean. We would recommend checking the ambient temperature sensor, part number PS3655657, and the evaporator thermistor, part number PS2359468. You can test these parts for continuity via a multimeter. Also, inspect the compressor capacitor, part number PS11700318. If this does not help, the problem is related to the electronic control board, part number PS9864896. We look forward to hearing from you if you need assistance with placing an order through our 7-days-a-week customer service. We hope this helps!

Was this helpful?
Thank you for voting!
Related Parts:
Jack
November 1, 2022
Unit keeps changing from heat to ac to eco to fan on its on and remote not working
For model number Ffrh1822r21
Hello Jack, thank you for contacting us. According to our research, the issue is probably with the PCB, part number PS9864875. It processes the temperature and fan settings you choose. Please reach out to customer service if you need help placing an order, anyone will be happy to assist you. We hope that helps.

Was this helpful?
Thank you for voting!
Customer Repair Stories
 Average Repair Rating: 2.8 / 5.0, 1 reviews. What's this?
Sort by:
Sorry, we couldn't find any existing installation instruction that matched.
A/C blows cold for 10 seconds then heating element comes on and blows hot
I bought both PC BOARDS and the 3 thermostats even tho I read that cleaning the thermostats will sometimes work. Installed thermostats but still blew hot. Installed push button control module because wife said the buttons don't always work, still blows hot.
Slide out A/C from frame about 8 inches, remove 4 screws that hold top cover. All the wires and thermostat connectors must be removed to get main control module out. I took lots of pictures and made my own wiring diagram with notes. The wire connectors look like regular push type, but they do have a release tab that can be pushed with needle nose plyers. Remove screws holding module, and do everything in reverse. Yes, the A/C works properly now. I spent an extra $110 for the thermostats and push button control, but am very happy it works and didn't have to buy a new A/C.
Other Parts Used:
PC BOARD
  • William from Selma, TX
  • Difficulty Level:
    Easy
  • Total Repair Time:
    1- 2 hours
  • Tools:
    Pliers, Screw drivers
4 of 4 people found this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Model Cross Reference
This part works with the following models:
PartSelect Number: PS9864875
Manufacturer Part Number: 5304496261
Brand
Model Number
Description
Crosley
CAH08ECR10
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAH08ECR11
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAH12ECR20
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAH18ECR20
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAH25ECR20
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE12ERR410A14
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE18ERR410A18
Air Conditioner - AIR CONDITIONER
Crosley
CAHE18ERR410A19
Air Conditioner - AIR CONDITIONER
Crosley
CAHE25ERR410A18
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE25ERR410A19
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE8ERR410A14
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE8ERR410A15
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE8ERR410A16
Air Conditioner - ROOM AIR CONDITIONER
Crosley
CAHE8ERR410A17
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822Q10
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822Q11
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822Q12
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822Q13
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822R10
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822R11
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH0822R12
Air Conditioner
Frigidaire
FFRH0822R13
Air Conditioner
Frigidaire
FFRH0822R14
Air Conditioner
Frigidaire
FFRH0822R1E0
Air Conditioner
Frigidaire
FFRH08L2R10
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH08L2R11
Air Conditioner - ROOM AIR CONDITIONER
Frigidaire
FFRH08L2R12
Air Conditioner
Frigidaire
FFRH08L2R13
Air Conditioner
Frigidaire
FFRH1122U10
Air Conditioner
Frigidaire
FFRH1122U1E0
Air Conditioner

Get in touch, we're here to help!

Open until 1am EST

Contact Customer Service