Cecil H - December 25, 2019
Verified Purchase
Easy Repair, and Freezing Cold Fridge!
The part works! It's amazing how well, in fact, when you purchase parts for the right model. Installation was easy enough, and this works to replace 2-wire or 3-wire relays. Thanks to customer service for tracking down the right one!
★★★★★
★★★★★
Earl B - May 22, 2019
Verified Purchase
Perfect part
This saves me from buying a new fridge. Perfect replacement to get fridge working. It had power, but only light came on. Needed to replace this part and now compressor comes on.
★★★★★
★★★★★
Marilyn M - March 8, 2019
Verified Purchase
Relay Terminals
I ordered the pictured part that had the exact same patent number as the original. The original part has one terminal. The received part has three terminals. I plugged the wire to the original position and the unit worked for awhile.
It would help if a short set of instructions was included with the part to cite which terminal to use with one wire.
Not sure why a patented part number is different than the one received.
< Prev
1
Next >
Customer Repair Stories
Average Repair Rating: 4.4 / 5.0, 1 reviews.
What's this?
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
Relay
Removed back panel. Opened cover to relay attached to the compressor and pulled off replacing with new relay. No problem.
Better than paying $250 for someone else to do it.
John H from Austin, TX
Difficulty Level:
Really Easy
Total Repair Time:
15 - 30 mins
41 of 52 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
< Prev
1
Next >
Questions and Answers
Ask our experts a question about this part and we'll get back to you as soon as possible!
4 questions answered by our experts.
Sort by:
< Prev
1
Next >
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Jesse
April 4, 2019
How do i test the Star relay if is good or bad and is there a second capacitor to be tested
For model number PDSS0MFYARSS
Hello Jesse, Thank you for the question. There is a Run Capacitor, Part #: PS11764031 you can test. You can check for continuity with a multi meter. Thank you for your inquiry, good luck with this repair!
1 person found this helpful.
Was this helpful?
Thank you for voting!
Jeff
June 27, 2019
Refrigerator is not cooling but not warm freezer is working fine but frosts up and frost keeps building what could my problem
For model number TBX18JISJRAD
Hello Jeff, Thank you for the question. I suggest testing the Defrost Thermostat, PartSelect Number PS303434. The best way to do this is to remove the thermostat from the refrigerator so you can control the temperature of the sensor. You can let the sensor warm up to room temperature. With the sensor warmed up to room temperature the sensor should read approximately 6.2K Ohms at 68°F. With the thermistor submerged is a glass full of ice water, the sensor should be very close to 32°F which should read approximately 16.3K Ohms. If the values that you are getting are far off from these readings, then the sensor is bad and should be replaced. Hope this helps!
The circuit breaker trips immediately upon plugging the refrigerator into the outlet. Background: the refrigerator was recently moved to a new location, but it was done carefully with evident damage to the lower rear of the refrigerator. I examined the wiring and can clearly see the Run capacitor and Start relay wiring which looks undisturbed and tied down. Can you suggest a troubleshooting method or a probable order of component failure?
For model number CTX18GISGRAD
Hello Stephen, Thank you for the question. If the compressor and the wiring to the compressor is good, We suggest Check all the defrost heater's connections to check this element isn't causing the fault. We hope this helps!
when electric is apply blows breakers discoenect wires electric breaker stays on but compressor doesn't come on
For model number TBX18SISGRWH
Hi Charlie, thank you for contacting us. Based on the description that you have provided, we would recommend checking the following parts: run capacitor, part number PS11764031, and start relay, part number PS963826. If the issue still exists, then you may need to check the compressor, part number PS895477. We hope this helps, good luck with this repair!