This part is used to generate microwave energy/heat.
How Buying OEM Parts Can Save You Time and Money
Troubleshooting
This part fixes the following symptoms:
No heat
This part works with the following products:
Microwave.
This part works with the following products:
General Electric.
Part# WB27X10682 replaces these:
AP3203599, 1086312, WB27X10559
Questions and Answers
We're sorry, but our Q&A experts are temporarily unavailable.
Please check back later if you still haven't found the answer you need.
6 questions answered by our experts.
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing answers that matched.Try using some different or simpler keywords, or submit your new question by using the "Ask a Question" button above!
Todd
July 15, 2019
Our microwave is only a couple years old and recently started to spark behind the wave guide cover (right side inner wall). What part is behind it that likely needs replaced? Thanks in advance for any help. Is it something that a diy can do?
For model number PEB7226SF2SS
Hi Todd, thank you for your question. Usually when you are having sparking inside of your microwave, the part to replace would be your wave guide cover itself there. You may also want to check if there is any metal showing on the inside of your microwave walls or anywhere else. I hope that helps. Good luck with your repair.
2 people found this helpful.
Was this helpful?
Thank you for voting!
JD
April 14, 2018
My microwave died while cooking. There is no power, no display, no lights, etc. Can you help?
For model number PEB7226SF2SS
Hello JD,
Thanks for your question. There are a few different parts that could cause this issue. You will want a licensed technician to test or install these parts, as your microwave's internal parts can contain electrical charges even when the machine is unplugged. Have the technician test the door switch, the magnetron, the thermostat, and the main control board.
I hope this helps.
My microwave works but does not heat. Can you help?
For model number PEB7226SF2SS
Hello Sergey,
Thanks for your question. There are a few different parts that could be at fault. You will want a licensed technician to test and install these parts as your microwave's internal components can contain electrical charges even when the microwave is unplugged. Have the technician check the diode, magnetron, high-voltage capacitor, transformer, and the control board.
I hope this helps.
My over stove GE microwave trips the breaker as soon as i touch the cook cycle button on the touch pad.
For model number JVM3160DF4BB
Hi Bill, thank you for your question. There are a few different parts that could be at fault. You will want a licensed technician to test and install these parts as your microwave's internal components can contain electrical charges even when the microwave is unplugged. Have the technician check the diode, magnetron, high-voltage capacitor, transformer, and the control board. I hope this helps.
Was this helpful?
Thank you for voting!
Buford Crutcher
November 18, 2019
My microwave started to spark and the heat stopped.
For model number PEB7226SF1SS
Hello Buford, thank you for your question. Sometimes if the stirrer cover is burnt or not seated correctly the unit can start to spark. We would recommend inspecting the inside of the microwave and checking for any burn marks or issues with the covers inside the unit. The sparking may have caused the magnetron to become faulty, or the diode which can cause the heating issues. I hope this helps!
Was this helpful?
Thank you for voting!
Pam
August 23, 2021
My tech repairman said I needed magnetron wb27x10682, however he did not have it in stock. I am unable to locate my microwave PEB7226DF2WW on any websites if I decide to replace the entire unit, is this still available or is there a comparable one? My unit is built in and measures 24 by 13 with trim kit 261/2 by 19. Any info would be greatly appreciated.
For model number PEB7226DF2WW
Hello Pam, Thank you for contacting PartSelect.com. Very sorry we do not sell appliances, just the replacement parts. We suggest contacting General Electric for replacement appliance information. We hope this helps!
Was this helpful?
Thank you for voting!
< Prev
1
Next >
Customer Repair Stories
Average Repair Rating: 3.3 / 5.0, 4 reviews.
What's this?
< Prev
1
Next >
Sort by:
Search filter:
Clear Filter
Your search term must have 3 or more characters.
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing installation instruction that matched.
The Microwave won't heat at normal heat settings; eg: from seconds to hours time settings.
First step was to discharge the transformer's capacitor (very important to do), before attempting any microwave repair. I opened the diagram/schematic found inside the microwave oven and followed the technician's troubleshooting steps; checked the capacitor; it checked OK, I checked the diode for a short, it checked OK. I checked the windings of the transformer that supply the power to the Magnetron; it checked Ok. I proceeded to order the parts; the Magnetron and the sensor located on the top part of the Magnetron. When the parts arrived; I went straight to the location of the Magnetron, I attached the new sensor on the new Magnetron and removed the old one. I connected the harness from the transformer to the new Magnetron and tested the microwave oven and it worked perfectly like a new one. This site has a great deal of information about repairs for the do it-yourself like myself, unlike other appliance's parts websites. Thumbs up to this site, I am very pleased with my order, I received it in a timely fashion as promised. I recommend it to everyone; this site is the best place to shop for appliances parts.
Everything Worked Fine But It Stopped Heating The Food.
Take the four saftey torx screws off the back of microwave that hold the side panels on. There are no screws in the front. Just pick up the side panels a little and slide towards the back of microwave and it will come off. The magnetron is visible behind control panel. Unplug the magetron, take a 3/8 nut driver , remove the one bolt that holds it on , remove and replace with the new one. Plug the wire (it will only go one way) back up and replace cover.
ROBERT from GAINESVILLE, TX
Difficulty Level:
Really Easy
Total Repair Time:
Less than 15 mins
Tools:
Nutdriver, Screw drivers
0 of 1 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
Both Intermittent- and No-Heating
First, I read the PartsSelect DIY report by Linda, Warsaw, IN. With confidence, I purchased the magnetron. Upon receipt, I took the built-in microwave out of the cabinet, set the unit on the kitchen floor, and was stopped cold by the Safety Torx nuts on the reverse of the unit. Borrowing the right wrench allowed the 20 minute start-to-finish part changeout and reinstallation of the unit in the cabinet to proceed. The old magnetron was the defective part. Discovery of the 10-year Parts-Only warranty on the less than 10-year old unit was insufficinet to guide me to take the unit in for their Labor bill to repair. New part in hand, it just was that easy - and assumed to be no less expensive.
Richard from Merritt Island, FL
Difficulty Level:
Easy
Total Repair Time:
15 - 30 mins
Tools:
Screw drivers
16 of 19 peoplefound this instruction helpful.
Was this instruction helpful to you?
Thank you for voting!
The microwave would no longer heat
First I ordered and replaced the diode. That did not help. Then I ordered both the magnetron and the thermostat magnetron because I didn't know what I was doing. After I replaced those, it still wouldn't heat. So I called an electrician. He noticed I had knocked a wire loose. I connected it and the microwave worked. I reconnected the old magnetron, just to test it. It didn't work. Then I put the new one back in. It's working just fine now! It took quite a while to put everything back in place because it was a built-in. But it was a lot cheaper than getting a new microwave, even with the cost of a repair man to show me I had a loose wire!
Keep searches simple. Use keywords, e.g. "leaking", "pump", "broken" or "fit".
Sorry, we couldn't find any existing reviews that matched. Try using some different or simpler keywords.
★★★★★
★★★★★
Stacy F - April 3, 2022
Verified Purchase
Worked perfectly!
Bought this for a built in microwave. Saved me from buying a new one for $700 +
★★★★★
★★★★★
Kirk J - December 17, 2018
Verified Purchase
Magnatron replacement
Turns out replacing a magnatron in a microwave oven is relatively easy. The replacement from PartsSelect arrived promptly and, once installed, works perfectly.
★★★★★
★★★★★
David R - April 19, 2018
Verified Purchase
fast delivery and restored my microwave
This is the second repair of my built-in GE microwave, so the disassembly and replacement of the magnetron was easy. My only concern is that this part may be designed by GE to have a short lifetime.
< Prev
1
Next >
Model Cross Reference
This part works with the following models:
PartSelect Number: PS953838
Manufacturer Part Number: WB27X10682
With the Fix app, you can quickly and easily find information on your appliance, along with videos and articles to help you fix it.
"Like magic. I took a picture of the model number on my refrigerator, and the app identified it right away … Very convenient. I'm impressed." ★★★★★ - Clever Jeff
★★★★★
You added 1 item to your cart
✖
$
Qty:
Total item(s) in cart:
Order Subtotal
$
*Taxes and shipping will be applied during checkout